THERMOSPRAY AND PARTICLE BEAM LIQUID-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS OF COUMARIN ANTICOAGULANTS

被引:24
|
作者
DEVRIES, JX [1 ]
KYMBER, KA [1 ]
机构
[1] INTERION LTD,MANCHESTER M33 2AA,ENGLAND
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 562卷 / 1-2期
关键词
D O I
10.1016/0378-4347(91)80561-P
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Positive ion mass spectra were obtained from several coumarin oral anticoagulants (phenprocoumon, warfarin, acenocoumarol and dicoumarol) and derivatives by liquid chromatography-thermospray mass spectrometry (LC-TSP-MS) and liquid chromatography-electron impact mass spectrometry (LC-EI-MS) to assess the use of LC-MS methods for the determination of these compounds in biological materials. LC-TSP mass spectra showed a single [M + 1]+ ion with no fragmentation; LC-EI mass spectra showed fragment ions which were similar in mass and relative intensities to those obtained by conventional EI-MS. These data should serve as a basis for the development of LC-MS methods for the qualitative and quantitative analysis of coumarin anticoagulants in biological samples. LC-TSP-MS was applied to the determination of phenprocoumon in a plasma extract from an anticoagulated patient.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 50 条
  • [21] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF PHYTOESTROGENS IN SOY PROTEIN PREPARATIONS WITH ULTRAVIOLET, ELECTROCHEMICAL AND THERMOSPRAY MASS-SPECTROMETRIC DETECTION
    SETCHELL, KDR
    WELSH, MB
    LIM, CK
    JOURNAL OF CHROMATOGRAPHY, 1987, 386 : 315 - 323
  • [22] LIQUID CHROMATOGRAPHIC-THERMOSPRAY MASS-SPECTROMETRIC ANALYSIS OF SESQUITERPENES OF ARMILLARIA (EUMYCOTA, BASIDIOMYCOTINA) SPECIES
    CREMIN, P
    DONNELLY, DMX
    WOLFENDER, JL
    HOSTETTMANN, K
    JOURNAL OF CHROMATOGRAPHY A, 1995, 710 (02) : 273 - 285
  • [23] THERMOSPRAY MASS-SPECTROMETRIC ANALYSIS OF PHENAZINES
    WATSON, D
    TAYLOR, GW
    WILSON, R
    COLE, PJ
    ROWE, C
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 17 (04): : 251 - 255
  • [24] DIRECT LIQUID INLET LIQUID-CHROMATOGRAPHIC MASS-SPECTROMETRIC IDENTIFICATION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF A BENZODIAZEPINE GLUCURONIDE
    DRAGNA, S
    AUBERT, C
    CANO, JP
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1989, 18 (06): : 359 - 362
  • [25] GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC AND LIQUID-CHROMATOGRAPHIC ANALYSIS OF DESIGNER BUTANAMINES RELATED TO MDMA
    CLARK, CR
    DERUITER, J
    VALAER, A
    NOGGLE, FT
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1995, 33 (06) : 328 - 337
  • [26] LIQUID-CHROMATOGRAPHIC DETERMINATION OF COUMARIN ANTICOAGULANTS IN TABLETS
    MOORE, E
    LAUCAM, C
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1986, 69 (04): : 629 - 632
  • [27] THERMOSPRAY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC MASS-SPECTROMETRIC CHARACTERIZATION OF BIOLOGICAL MACROMOLECULES .1. ANALYSIS OF ACID HYDROLYSATE OF PEPTIDES
    CHEN, TM
    COUTANT, JE
    JOURNAL OF CHROMATOGRAPHY, 1989, 463 (01): : 95 - 106
  • [28] LIQUID-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS OF N-ACETYLAMINO ACIDS IN HUMAN URINE
    SUGAHARA, K
    JIANYING, Z
    KODAMA, H
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 657 (01): : 15 - 21
  • [29] LIQUID-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS FOR SCREENING OF PATIENTS WITH CYSTINURIA, AND IDENTIFICATION OF CYSTINE STONE
    WATANABE, H
    SUGAHARA, K
    INOUE, K
    FUJITA, Y
    KODAMA, H
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 568 (02): : 445 - 450
  • [30] LIQUID-CHROMATOGRAPHIC MASS-SPECTROMETRIC DETERMINATION OF OPTICALLY-ACTIVE DRUGS
    CROWTHER, JB
    COVEY, TR
    DEWEY, EA
    HENION, JD
    ANALYTICAL CHEMISTRY, 1984, 56 (14) : 2921 - 2926