Evaluation of Safety of Postplacental Intrauterine Contraceptive Device (IUCD) Insertion in Lower Segment Caesarean Section (LSCS)

被引:0
|
作者
Akram, Sara [1 ]
Saeed, Shazia [1 ]
Akhter, Nasreen [1 ]
Ahmad, Ashfaq [2 ]
Salam, Rohana [1 ]
机构
[1] Divis Head Quarter Teaching Hosp, Gynae & Obs, Mirpur, Azad Jamu Kashm, Pakistan
[2] Divis Head Quarter Teaching Hosp, Gynae & Obs, Urol, Mirpur, Azad Jamu Kashm, Pakistan
来源
关键词
Intrauterine Contraceptive Device; Lower Segment Caesarean Section; Fibroid Uterus;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Increasing population is a threat and burden on resources in developing countries so effective use of contraception may reduce this burden. Aim: To evaluate safety of post placental insertion of IUCD in LSCS in term of maternal complication. Place and Duration: DHQ Teaching Hospital Mirpur, AJK during 1st January, 2017 to 30th June, 2018. Methods: Total 100 cases were selected and follow up done on 6 week postpartum and 6 month after delivery. Patients demographic data and record with follow up dates and all complication like expulsion, displace IUCD, perforation, hemorrhage and sepsis were noted on pre-design proforma. IUCD was inserted at time of LSCS after excluding condition like anemia, major degree placenta previa, cardiac diseases, uncontrolled GDM, fibroid uterus chorioamnonites and patient not willing for this method. Results: The mean age of the patients was 29.42 +/- 3.96. Total 86 patients out of 100 completed their follow up upto 6 month while in one patient IUCD was removed due to her persistent pelvic pain at 6 week postpartum. Menorrhagia was observed in 03 patients, no other complication like expulsion, perforation and sepsis observed. Conclusion: It is a safe procedure of contraception should encourage without hesitation.
引用
收藏
页码:1384 / 1385
页数:2
相关论文
共 36 条
  • [21] Effectiveness, safety, and acceptability of postplacental insertion of GyneFix postpartum intrauterine device among women undergoing cesarean section: A multicenter prospective cohort study in China
    Che, Yan
    Hou, Gui-Fang
    Zhang, Hong-Ping
    Yang, Heng
    Lin, Shu-Juan
    Gan, Tao
    Yang, Wei-Hua
    Shi, Chun-Hui
    Ren, Wei-Juan
    Xu, Ying-Qin
    Yin, Bao-Ming
    Chen, Ting -Ting
    Gan, Yu-Jie
    Zhang, Yuan
    Zhang, Yan
    Cheng, Li-Nan
    CONTRACEPTION, 2023, 122
  • [22] RETENSION RATE OF INTRA CAESARIAN INSERTION OF INTRAUTERINE CONTRACEPTIVE DEVICE AND EVALUATION OF COMPLICATIONS
    George, Suja Mary
    George, Mary
    Soman, Annie
    Bavan, Deepa
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (20): : 3522 - 3531
  • [23] An audit of post analgesic requirements in women undergoing lower segment caesarean section (LSCS) in a district general hospital maternity unit
    Oti, C.
    Ukor, I.
    Schneider-Smith, T.
    ANAESTHESIA, 2013, 68 : 88 - 88
  • [24] Visibility of Strings After Postplacental Intracesarean Insertion of CuT380A and Cu375 Intrauterine Contraceptive Device: A Randomized Comparative Study
    Agarwal K.
    Dewan R.
    Mittal P.
    Aggarwal A.
    The Journal of Obstetrics and Gynecology of India, 2017, 67 (5) : 324 - 329
  • [25] Enhancing contraceptive usage by post-placental intrauterine contraceptive devices (PPIUCD) insertion with evaluation of safety, efficacy, and expulsion
    Ramachandra, C.
    Kittur, S.
    Kabadi, Y. M.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2013, 120 : 213 - 213
  • [26] Patient acceptability, continuation and complication rates with immediate postpartum levonorgestrel intrauterine device insertion at caesarean section and vaginal birth
    Wojcik, Natasha
    Watkins, Leah
    Nugent, Rachael
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2022, 62 (05): : 773 - 778
  • [27] Anticipated vs actual experienced pain at site of spinal needle insertion in patients undergoing elective lower segment caesarean section
    Bin Ghaffar, Waleed
    Minai, Fauzia
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 1054 - 1054
  • [28] The characterisation of long-acting reversible contraception (LARC) provision in primary care, April 2012 to March 2013-Nexplanon and intrauterine-contraceptive device (IUCD) insertion
    Briggs, A.
    Buddery, A.
    Powles, E.
    HIV MEDICINE, 2014, 15 : 150 - 150
  • [29] Intrauterine Copper Device (CuT380A) as a Contraceptive Method in the Indian Context: Acceptability, Safety and Efficacy Depending on the Timing of Insertion
    Gupta P.
    Gupta M.M.
    Sharma R.
    The Journal of Obstetrics and Gynecology of India, 2018, 68 (2) : 129 - 135
  • [30] Evaluation of Safety, Efficacy, and Expulsion of Post-Placental and Intra-Cesarean Insertion of Intrauterine Contraceptive Devices (PPIUCD)
    Sujnanendra, Mishra
    JOURNAL OF OBSTETRICS AND GYNECOLOGY OF INDIA, 2014, 64 (05): : 337 - 343