MEASUREMENT AND ANALYSIS-METHODS FOR CRITICAL FLICKER FREQUENCY AND OBSERVER FATIGUE CAUSED BY TELEVISION WATCHING

被引:5
|
作者
MITSUHASHI, T
机构
[1] Nhk Science and Technical Research Laboratories, Tokyo
关键词
TV WATCHING; CFF; FATIGUE; BINOCULAR 3-D TV;
D O I
10.1002/ecjc.4430780601
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Aiming at the quantitative measurement of the fatigue of the television observer, a new practical and simple method of critical flicker frequency (CFF) measurement and analysis is considered. As to the measurement, a method is considered where the CFF at the start of the measurement is used as the initial value and the relative change is measured in a short time with a high accuracy.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [31] Measurement of critical flicker frequency at extremely low luminance levels and flicker-less 20Hz reset drive of PDPs
    Sakai, S.
    Shiga, T.
    Mikoshiba, S.
    IDW '07: PROCEEDINGS OF THE 14TH INTERNATIONAL DISPLAY WORKSHOPS, VOLS 1-3, 2007, : 2113 - 2116
  • [32] Evaluation of critical flicker-fusion frequency measurement methods using a touchscreen-based visual temporal discrimination task in the behaving mouse
    Nomura, Yuichiro
    Ikuta, Shohei
    Yokota, Satoshi
    Mita, Junpei
    Oikawa, Mami
    Matsushima, Hiroki
    Amano, Akira
    Shimonomura, Kazuhiro
    Seya, Yasuhiro
    Koike, Chieko
    NEUROSCIENCE RESEARCH, 2019, 148 : 28 - 33
  • [33] QUANTAL MEASUREMENT AND ANALYSIS-METHODS COMPARED FOR CRAYFISH AND DROSOPHILA NEUROMUSCULAR-JUNCTIONS, AND RAT HIPPOCAMPUS
    COOPER, RL
    STEWART, BA
    WOJTOWICZ, JM
    WANG, S
    ATWOOD, HL
    JOURNAL OF NEUROSCIENCE METHODS, 1995, 61 (1-2) : 67 - 78
  • [34] Evaluation of critical flicker fusion frequency and perceived fatigue in divers after air and enriched air nitrox diving
    Lafere, Pierre
    Balestra, Costantino
    Hemelryck, Walter
    Donda, Nicola
    Sakr, Ahmed
    Taher, Adel
    Marroni, Sandro
    Germonpre, Peter
    DIVING AND HYPERBARIC MEDICINE, 2010, 40 (03) : 114 - 118
  • [35] Meta-analysis: the diagnostic accuracy of critical flicker frequency in minimal hepatic encephalopathy
    Torlot, F. J.
    McPhail, M. J. W.
    Taylor-Robinson, S. D.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2013, 37 (05) : 527 - 536
  • [36] MEASURING RECOVERY FROM GENERAL-ANESTHESIA USING - CRITICAL FLICKER FREQUENCY - A COMPARISON OF 2 METHODS
    SALIB, Y
    PLOURDE, G
    ALLOUL, K
    PROVOST, A
    MOORE, A
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (10): : 1045 - 1050
  • [37] DEVELOPMENT OF EIGENMODE AND FREQUENCY-RESPONSE SENSITIVITY ANALYSIS-METHODS FOR COUPLED ACOUSTIC-STRUCTURAL SYSTEMS
    HAGIWARA, I
    MA, ZD
    JSME INTERNATIONAL JOURNAL SERIES III-VIBRATION CONTROL ENGINEERING ENGINEERING FOR INDUSTRY, 1992, 35 (02): : 229 - 235
  • [38] MATHEMATICAL BASIS FOR THE MEASUREMENT OF ABSOLUTE AND FRACTIONAL CARDIAC-OUTPUT WITH DIFFUSIBLE TRACERS BY COMPARTMENTAL ANALYSIS-METHODS
    CHARKES, ND
    JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1984, 12 (05): : 517 - 524
  • [39] Is critical flicker-fusion frequency a valid measure of visual fatigue? A post-hoc analysis of a double-masked randomised controlled trial
    Singh, Sumeer
    Downie, Laura E. E.
    Anderson, Andrew J. J.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (02) : 176 - 182
  • [40] FATIGUE ANALYSIS OF METALLIC COMPONENTS USING CRITICAL DISTANCE METHODS
    Chattopadhyay, Somnath
    IMECE 2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 11, 2010, : 11 - 16