Central aortic blood pressure and augmentation index: comparison between Vasotens (R) and SphygmoCor (R) technology

被引:0
|
作者
Rogoza, Anatoliy N. [1 ]
Kuznetsov, Aleksandr A. [2 ]
机构
[1] Cardiol Res Complex, 3rd Cherpkovskaya Str15a, Moscow 121552, Russia
[2] Russian Acad Med Sci, Therapy Res Inst, Siberian branch, Novosibirsk, Russia
关键词
central aortic blood pressure; augmentation index; validation; Vasotens (R); BPLab (R);
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The aim of this study is the comparison of Vasotens (R) technology as used in a device with an oscillometric method of blood pressure measurement (BPLab, Petr Telegin Ltd, Nizhny Novgorod, Russian Federation) against the validated tonometric system (SphygmoCor (R), AtCor Medical Pty Ltd, West Ryde, Australia). Methods: The examinations were carried out in two medical centers. Exclusion criteria included atrial fibrillation, severe cardiac anomalies, heart failure, arrhythmia, decompensated diabetes, the presence of an artificial pacemaker, pregnancy, and BMI. 30. Overall, 160 patients and healthy volunteers were examined. Central aortic systolic blood pressure (aSBP) and augmentation index (aAIx) were obtained by means of applanation tonometry and the oscillometric method was compared. Results: aSBP and aAIx measured using the BPLab device equates significantly with the same parameters measured by SphygmoCor. Conclusion: This finding allows the recommendation of Vasotens technology, which can be used with the 24- hour BPLab monitoring system for wide clinical use.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [41] Sex differences in the contribution of blood pressure to acute changes in aortic augmentation index
    Eliza Prodel
    Thales C. Barbosa
    Iuri Galdino
    Antonio C. Nobrega
    Lauro C. Vianna
    [J]. Journal of Human Hypertension, 2018, 32 : 752 - 758
  • [42] Oscillometric estimation of central blood pressure: validation of the Mobil-O-Graph in comparison with the SphygmoCor device
    Weiss, Wolfgang
    Gohlisch, Christopher
    Harsch-Gladisch, Christl
    Toelle, Markus
    Zidek, Walter
    van der Giet, Markus
    [J]. BLOOD PRESSURE MONITORING, 2012, 17 (03) : 128 - 131
  • [43] Central aortic blood pressure, augmentation index, and reflected wave transit time: reproducibility and repeatability of data obtained by oscillometry
    Ageenkova, Olga A.
    Purygina, Marina A.
    [J]. VASCULAR HEALTH AND RISK MANAGEMENT, 2011, 7 : 649 - 656
  • [44] VICORDER APPARATUS FOR NON-INVASIVE ASSESSMENT OF CENTRAL BLOOD PRESSURE: REPEATABILITY AND COMPARISON WITH THE SPHYGMOCOR DEVICES
    Pucci, G.
    Whittaker, L.
    Hickson, S. S.
    Cheriyan, J.
    Schillaci, G.
    Mceniery, C. M.
    Wilkinson, I. B.
    [J]. JOURNAL OF HYPERTENSION, 2010, 28 : E167 - E167
  • [45] Estimates of arterial stiffness and central blood pressure in patients with type 2 diabetes: A comparison of SphygmoCor and Arteriograph
    Krogager, Christoffer
    Rossen, Niklas B.
    Hansen, Klavs W.
    Knudsen, Soren T.
    Peters, Christian D.
    Botker, Hans Erik
    Poulsen, Per L.
    Laugesen, Esben
    [J]. ARTERY RESEARCH, 2016, 16 : 18 - 24
  • [46] Comparison between Mobil-O-Graph and the SphygmoCor device for central systolic blood pressure estimation: consensus is required for 'validation protocols'
    Papaioannou, Theodore G.
    Protogerou, Athanasse
    Stefanadis, Christodoulos
    [J]. BLOOD PRESSURE MONITORING, 2012, 17 (06) : 259 - 260
  • [47] P7.06 Central Blood Pressure and Augmentation Index of Healthy Youth
    E. Komonyi
    Sz. Lengyel
    M. Juhász
    E. Katona
    Gy Paragh
    B. Fülesdi
    J. Zatik
    D. Páll
    [J]. Artery Research, 2009, 3 (4) : 184 - 184
  • [48] MARATHON IMPROVED CENTRAL BLOOD PRESSURE, AUGMENTATION INDEX, AND ENDOTHELIAL PROGENITOR CELLS
    Park, J. H.
    Do-Sun, L.
    Hyo-Jung, N.
    [J]. ATHEROSCLEROSIS, 2019, 287 : E262 - E262
  • [49] Increased central pressure and augmentation index in subjects with normal causal but elevated ambulatory blood pressure
    Liu, LF
    [J]. JOURNAL OF HYPERTENSION, 2004, 22 : S140 - S141
  • [50] Impact of simultaneous measurement of central blood pressure with the SphygmoCor Xcel during MRI acquisition to better estimate aortic distensibility
    Soulat, Gilles
    Millasseau, Sandrine
    Stroer, Sebastian
    Tavolaro, Sebastian
    Kachenoura, Nadjia
    Khettab, Hakim
    Boutouyrie, Pierre
    Laurent, Stephane
    Mousseaux, Elie
    [J]. JOURNAL OF HYPERTENSION, 2019, 37 (07) : 1448 - 1454