Central aortic blood pressure and augmentation index: comparison between Vasotens (R) and SphygmoCor (R) technology

被引:0
|
作者
Rogoza, Anatoliy N. [1 ]
Kuznetsov, Aleksandr A. [2 ]
机构
[1] Cardiol Res Complex, 3rd Cherpkovskaya Str15a, Moscow 121552, Russia
[2] Russian Acad Med Sci, Therapy Res Inst, Siberian branch, Novosibirsk, Russia
关键词
central aortic blood pressure; augmentation index; validation; Vasotens (R); BPLab (R);
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The aim of this study is the comparison of Vasotens (R) technology as used in a device with an oscillometric method of blood pressure measurement (BPLab, Petr Telegin Ltd, Nizhny Novgorod, Russian Federation) against the validated tonometric system (SphygmoCor (R), AtCor Medical Pty Ltd, West Ryde, Australia). Methods: The examinations were carried out in two medical centers. Exclusion criteria included atrial fibrillation, severe cardiac anomalies, heart failure, arrhythmia, decompensated diabetes, the presence of an artificial pacemaker, pregnancy, and BMI. 30. Overall, 160 patients and healthy volunteers were examined. Central aortic systolic blood pressure (aSBP) and augmentation index (aAIx) were obtained by means of applanation tonometry and the oscillometric method was compared. Results: aSBP and aAIx measured using the BPLab device equates significantly with the same parameters measured by SphygmoCor. Conclusion: This finding allows the recommendation of Vasotens technology, which can be used with the 24- hour BPLab monitoring system for wide clinical use.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [1] P8.09 A Comparison of Central Blood Pressures, Augmentation Index and Pwv Estimated by «Bplab Vasotens» and Sphygmocor
    A. N. Rogoza
    N. M. Moiseeva
    M. V. Sergeeva
    [J]. Artery Research, 2010, 4 (4) : 171 - 171
  • [2] Comparison of estimates of central blood pressure and augmentation index obtained by the SphygmoCor and Omron HEM-9000 devices
    Kamalesh, T.
    McNeil, K. L.
    Millasseau, S. C.
    Chowienczyk, P. J.
    [J]. JOURNAL OF HYPERTENSION, 2006, 24 : S288 - S288
  • [3] Augmentation index and central aortic blood pressure in patients with abdominal aortic aneurysms
    Ruegg, Gion
    Mason, Rebecca H.
    Hardinge, Maxine
    Perkins, Jeremy
    Husmann, Marc
    Russi, Erich W.
    Bloch, Konrad E.
    Stradling, John R.
    Kohler, Malcolm
    [J]. JOURNAL OF HYPERTENSION, 2010, 28 (11) : 2252 - 2257
  • [4] Central aortic blood pressure and augmentation index during normal pregnancy
    Mika Fujime
    Takuji Tomimatsu
    Yuko Okaue
    Shinsuke Koyama
    Takeshi Kanagawa
    Takeshi Taniguchi
    Tadashi Kimura
    [J]. Hypertension Research, 2012, 35 : 633 - 638
  • [5] Central aortic blood pressure and augmentation index during normal pregnancy
    Fujime, Mika
    Tomimatsu, Takuji
    Okaue, Yuko
    Koyama, Shinsuke
    Kanagawa, Takeshi
    Taniguchi, Takeshi
    Kimura, Tadashi
    [J]. HYPERTENSION RESEARCH, 2012, 35 (06) : 633 - 638
  • [6] A comparison between central blood pressure values obtained by the Gaon system and the SphygmoCor system
    Jun Hyuk Kang
    Dae In Lee
    Sua Kim
    Sun Won Kim
    Sung Il Im
    Jin Oh Na
    Cheol Ung Choi
    Hong Euy Lim
    Jin Won Kim
    Eung Ju Kim
    Seung Woo Han
    Seung-Woon Rha
    Hong Seog Seo
    Dong Joo Oh
    Chang Gyu Park
    [J]. Hypertension Research, 2012, 35 : 329 - 333
  • [7] A comparison between central blood pressure values obtained by the Gaon system and the SphygmoCor system
    Kang, Jun Hyuk
    Lee, Dae In
    Kim, Sua
    Kim, Sun Won
    Im, Sung Il
    Na, Jin Oh
    Choi, Cheol Ung
    Lim, Hong Euy
    Kim, Jin Won
    Kim, Eung Ju
    Han, Seung Woo
    Rha, Seung-Woon
    Seo, Hong Seog
    Oh, Dong Joo
    Park, Chang Gyu
    [J]. HYPERTENSION RESEARCH, 2012, 35 (03) : 329 - 333
  • [8] Comparison of estimates of central systolic blood pressure and peripheral augmentation index obtained from the Omron HEM-9000AI and SphygmoCor systems
    Richardson C.J.
    Maki-Petaja K.M.
    McDonnell B.J.
    Hickson S.S.
    Wilkinson I.B.
    McEniery C.M.
    [J]. Artery Research, 2009, 3 (1) : 24 - 31
  • [9] Comparison of two measuring instruments, B-pro and SphygmoCor system as reference, to evaluate central systolic blood pressure and radial augmentation index
    Garcia-Ortiz, Luis
    Recio-Rodriguez, Jose I.
    Canales-Reina, Joan J.
    Cabrejas-Sanchez, Alfredo
    Gomez-Arranz, Amparo
    Magdalena-Belio, Jose F.
    Guenaga-Saenz, Nahia
    Agudo-Conde, Cristina
    Gomez-Marcos, Manuel A.
    [J]. HYPERTENSION RESEARCH, 2012, 35 (06) : 617 - 623
  • [10] Increased augmentation index and central aortic blood pressure in osteoporotic postmenopausal women
    R. A. Mangiafico
    C. Alagona
    P. Pennisi
    N. Parisi
    M. Mangiafico
    F. Purrello
    C. E. Fiore
    [J]. Osteoporosis International, 2008, 19 : 49 - 56