Shear bond strength of composite resin to dentin after application of cavity disinfectants - SEM study

被引:18
|
作者
Sharma, Vivek [1 ]
Rampal, Poonam [2 ]
Kumar, Sukesh [3 ]
机构
[1] DJ Coll Dent Sci & Res, Dept Conservat Dent & Endodont, Modinagar, Uttar Pradesh, India
[2] DJ Coll Dent Sci & Res, Prosthodont, Modinagar, Uttar Pradesh, India
[3] Inst Dent Studies & Technol, Dept Conservat Dent & Endodont, Meerut, Uttar Pradesh, India
关键词
Benzalkonium chloride based disinfectant; composite resin; cavity disinfection; CHX gel and solution; iodine potassium iodide; copper sulfate based disinfectant;
D O I
10.4103/0976-237X.86438
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The aim was to evaluate the effect of different cavity disinfectants on dentin bond strengths of composite resin applied with two different adhesive systems. Materials and Methods: Two-hundred mandibular molars were sectioned parallel to the occlusal surface to expose dentin in the midcoronal one-third. The dentinal surfaces were polished with waterproof-polishing papers. The specimens were randomly divided into five groups of 40 teeth each as follows: group 1(control) -- specimens were not treated with any cavity disinfectants. Groups 2--5 (experimental groups) -- dentin surfaces were treated with the following cavity disinfectants, respectively; 2% chlorhexidine solution, 0.1% benzalkonium chloride-based disinfectant, 1% chlorhexidine gel, and an iodine potassium iodide/copper sulfate-based disinfectant. The specimens were then randomly divided into two subgroups including 20 teeth each to evaluate the effect of different bonding systems. Dentin bonding systems were applied to the dentin surfaces and the composite buildups were done. After the specimens were stored in an incubator for 24 hours, the shear bond strength was measured at a crosshead speed of 1 mm/min. The specimens were then statistically analyzed. Statistical Analysis Used: One way analysis of variance and Tukey-HSD tests were used. Results: There was no significant difference between chlorhexidine gel and control groups regardless of the type of the bonding agent used (P > 0.05). On the other hand, pretreatment with benzalkonium chloride-based, iodine potassium iodide/copper sulfate-based disinfectants or chlorhexidine solutions had a negative effect on the shear bond strength of self-etching bonding systems. Conclusions: The findings of this study suggest that when benzalkonium chloride-based, iodine potassium iodide/copper sulfate-based disinfectants or chlorhexidine solutions are used as a cavity disinfectant, an etch-and-rinse bonding system should be preferred.
引用
收藏
页码:155 / 159
页数:5
相关论文
共 50 条
  • [31] Effect of Different Composite Placement Molds on Resin-Enamel/Dentin Shear Bond Strength
    Ayar, Muhammet Kerim
    Yesilyurt, Cemal
    Yildirim, Tahsin
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2016, 4 (02): : 141 - 145
  • [32] SHEAR BOND STRENGTHS OF COMPOSITE RESIN TO DENTIN TREATED WITH OPTIBOND
    TJAN, AHL
    DUNN, JR
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 199 - 199
  • [33] Bond strength of composite to enamel after application of dentin bonding agents
    Ganss, C
    Buenker, H
    Dressler, S
    Klimek, J
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1228 - 1228
  • [34] Microtensile Bond Strength Evaluation of Composite Resin to Discolored Dentin After Amalgam Removal
    Mandava, Jyothi
    Pamidimukkala, Sahithi
    Karumuri, Srujana
    Ravi, Ravichandra
    Borugadda, Roopesh
    Afraaz, Abdul
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (04)
  • [35] Influence of curing rate of resin composite on the bond strength to dentin
    Benetti, A. R.
    Asmussen, E.
    Peutzfeldt, A.
    OPERATIVE DENTISTRY, 2007, 32 (02) : 144 - 148
  • [36] COMPOSITE RESIN-DENTIN BOND STRENGTH WITH COUPLING AGENTS
    BEIGELIS, AA
    MACCHI, RL
    JOURNAL OF DENTAL RESEARCH, 1987, 66 (04) : 809 - 809
  • [37] Microshear Bond Strength of Bioactive Materials to Dentin and Resin Composite
    Ahmed, Basma
    Hamama, Hamdi H.
    Mahmoud, Salah Hasab
    EUROPEAN JOURNAL OF DENTISTRY, 2023, 17 (03) : 917 - 923
  • [38] The influence of micro hardness in composite resin bond strength to dentin
    Turbino, ML
    Matson, E
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 966 - 966
  • [39] The effect of surface treatment on the bond strength of resin composite to dentin
    Benderli, Y
    Yücel, T
    OPERATIVE DENTISTRY, 1999, 24 (02) : 96 - 102
  • [40] Effect of mucoprotein on the bond strength of resin composite to human dentin
    Pinzon, Lilliam Marie
    Powers, John M.
    O'Keefe, Kathy L.
    Dusevish, Vladimir
    Spencer, Paulette
    Marshall, Grayson W.
    ODONTOLOGY, 2011, 99 (02) : 119 - 128