ASYMMETRIC FABRY-PEROT DEVICE ARRAYS WITH LOW INSERTION LOSS AND HIGH UNIFORMITY

被引:6
|
作者
JENNINGS, A [1 ]
HORAN, P [1 ]
KELLY, B [1 ]
HEGARTY, J [1 ]
机构
[1] UNIV DUBLIN TRINITY COLL, HITACHI DUBLIN LAB, DUBLIN 2, IRELAND
关键词
D O I
10.1109/68.149887
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report on arrays of normally ON asymmetric Fabry-Perot modulator (AFPM) devices which exhibit a high degree of uniformity between devices, with a thickness variation across an array of 0.07%. The devices in one array have a mean insertion loss of 1.8 dB, and OFF reflectivities of less than 3%, giving a mean contrast ratio of 22:1. These characteristics are measured at a single operating wavelength of 857 nm. The spatial light modulators show promise for the use of AFPM devices in optical processing.
引用
收藏
页码:858 / 860
页数:3
相关论文
共 50 条
  • [41] LAYER UNIFORMITY OBTAINED BY VACUUM EVAPORATION - APPLICATION TO FABRY-PEROT FILTERS
    GREZESBESSET, C
    RICHIER, R
    PELLETIER, E
    APPLIED OPTICS, 1989, 28 (14) : 2960 - 2964
  • [42] Readout of micromechanical cantilever sensor arrays by Fabry-Perot interferometry
    Wehrmeister, Jana
    Fuss, Achim
    Saurenbach, Frank
    Berger, Ruediger
    Helm, Mark
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (10):
  • [43] Optimization of bicrystal Josephson junctions and arrays in a Fabry-Perot resonator
    He, M.
    Klushin, A. M.
    Yan, S. L.
    Klein, N.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 934 - 937
  • [44] CHARACTERISTICS OF FABRY-PEROT ELECTROOPTIC MODULATORS WITH INTERNAL LOSS
    LOTSPEICH, JF
    APPLIED OPTICS, 1973, 12 (06) : 1109 - 1110
  • [45] LOSS MEASUREMENTS FOR AN OPTICAL CAVITY WITH A FABRY-PEROT ETALON
    PINAYEV, IV
    POPIK, VM
    SHAFTAN, TV
    SOKOLOV, AS
    VINOKUROV, NA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 341 (1-3): : AB132 - AB133
  • [46] Ultrafast all-optical switching with an asymmetric Fabry-Perot device using low-temperature-grown GaAs: Material and device issues
    Loka, HS
    Smith, PWE
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 2000, 36 (01) : 100 - 111
  • [47] HIGH CONTRAST IN A POLYETALON FABRY-PEROT SPECTROMETER
    DAEHLER, M
    ROESLER, FL
    APPLIED OPTICS, 1968, 7 (06): : 1240 - &
  • [48] NEFER, A HIGH RESOLUTION FABRY-PEROT SPECTROMETER
    Bernal, A.
    Rosado, M.
    Cepa, J.
    Martinez, L. A.
    FOURTH SCIENCE MEETING WITH THE GTC, 2013, 42 : 128 - 128
  • [49] A fiber Fabry-Perot cavity with high finesse
    Hunger, D.
    Steinmetz, T.
    Colombe, Y.
    Deutsch, C.
    Haensch, T. W.
    Reichel, J.
    NEW JOURNAL OF PHYSICS, 2010, 12
  • [50] High-Gain Fabry-Perot Resonator
    Sun, Y.
    Ding, Y.
    Zhang, Y.
    2013 INTERNATIONAL WORKSHOP ON ANTENNA TECHNOLOGY (IWAT), 2013, : 125 - 128