SHORT-TERM VARIATION IN BLOOD-PRESSURE DETERMINES THE ACCURACY OF SIMULTANEOUS AND SEQUENTIAL RECORDINGS IN THE VALIDATION OF BLOOD-PRESSURE MEASURING DEVICES

被引:0
|
作者
SCHWAN, A
JONSSON, D
机构
关键词
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Short-term intradevice variation of BP was determined by means of consecutive BP recordings. The intradevice variation was mainly the result of spontaneous, random variation in BP and was the same for invasive, automated oscillometric and auscultatory random zero meter recordings. We show that the accuracy of simultaneous and sequential recording's, performed according to the recommendation of the British Hypertension Society's protocol for the evaluation of automated BP devices, can be calculated by means of statistical analysis if the intradevice variation of the BP is known. We found, for both sequential and for simultaneous recordings, a close agreement between the expected and the observed proportion of differences that fall within certain specified limits and that it is more favourable for a test device to be evaluated by sequential than by simultaneous recordings.
引用
下载
收藏
页码:315 / 319
页数:5
相关论文
共 50 条
  • [21] MEASURING BLOOD-PRESSURE
    不详
    LANCET, 1966, 1 (7434): : 414 - +
  • [22] MEASURING BLOOD-PRESSURE
    不详
    BRITISH MEDICAL JOURNAL, 1975, 4 (5993): : 366 - 367
  • [23] DESIGNING NEW DEVICES FOR MEASURING BLOOD-PRESSURE
    GOLDENRING, JM
    WESTERN JOURNAL OF MEDICINE, 1984, 141 (05): : 687 - 687
  • [24] COMPARISON OF 3 DEVICES FOR MEASURING BLOOD-PRESSURE
    BASSEIN, L
    BORGHI, C
    COSTA, FV
    STROCCHI, E
    MUSSI, A
    AMBROSIONI, E
    STATISTICS IN MEDICINE, 1985, 4 (03) : 361 - 368
  • [25] SPECTRAL-ANALYSIS OF SHORT-TERM VARIABILITY OF BLOOD-PRESSURE AND PULSE INTERVAL USING FINGER BLOOD-PRESSURE MONITORING
    ELGHOZI, JL
    GIRARD, A
    LAUDE, D
    VALENSI, P
    WEISE, F
    HOMEOSTASIS IN HEALTH AND DISEASE, 1995, 36 (2-3): : 153 - 159
  • [26] REPRODUCIBILITY OF SHORT-TERM VARIABILITY OF BLOOD-PRESSURE - A SPECTRAL STUDY
    GIRARD, A
    LAUDE, D
    ELGHOZI, JL
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1994, 87 (08): : 1079 - 1082
  • [27] SHORT-TERM (6 HOUR), AMBULATORY BLOOD-PRESSURE MONITORING
    SHEPS, SG
    BAILEY, KR
    ZACHARIAH, PK
    JOURNAL OF HUMAN HYPERTENSION, 1994, 8 (12) : 873 - 878
  • [28] SHORT-TERM EFFECT OF DYNAMIC EXERCISE ON ARTERIAL BLOOD-PRESSURE
    PESCATELLO, LS
    FARGO, AE
    LEACH, CN
    SCHERZER, HH
    CIRCULATION, 1991, 83 (05) : 1557 - 1561
  • [29] CHANGES IN BLOOD-PRESSURE AND PLASMA NORADRENALINE IN SHORT-TERM HYPOTHYROIDISM
    BROWN, RT
    LAKSHMANAN, MC
    BAUCOM, CE
    POLINSKY, RJ
    CLINICAL ENDOCRINOLOGY, 1989, 30 (06) : 635 - 638
  • [30] SELF BLOOD-PRESSURE DEVICES ARE NOT FREQUENTLY CHECKED FOR ACCURACY
    GRIM, CM
    GRIM, CE
    PREVENTIVE MEDICINE, 1978, 7 (01) : 79 - 79