24 YEARS IMPLANT DURATION OF THE AORTIC STARR-EDWARDS SILASTIC BALL PROSTHESIS - A VALVE OF THE PAST

被引:5
|
作者
MACHLER, HE
SCHMIDT, CH
NEUNER, P
IBERER, F
ANELLIMONTI, M
DACAR, D
RIGLER, B
KRAFTKINZ, J
机构
[1] Department of Surgery, University of Graz
[2] Institute of Pathology, University of Graz
关键词
AORTIC STARR-EDWARDS BALL PROSTHESIS; LONGEVITY; RELIABILITY;
D O I
10.1016/1010-7940(93)90031-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Six years after the first aortic valve replacement with the Starr-Edwards Silastic ball prosthesis at Oregon Health Sciences University, the model 1260 was implanted in a 44-year-old patient at our department. During 24 years no signs of dysfunction, thromboembolism, thrombosis, periprosthetic leaks or hemolysis were observed. Material test showed no signs of fatigue. The dimension of the Silastic poppet was found to be one millimeter less than the original specifications of these poppets and there were some lipid infiltrations. Functionally the poppet was found to be nonvariant. Histologic findings detected focal hyalinization and giant cells without signs of acute inflammation or ulceration. With regard to its reliability and durability, the Starr-Edwards valve prosthesis should not be viewed with disfavor.
引用
收藏
页码:114 / 116
页数:3
相关论文
共 50 条
  • [41] FUNCTIONAL RESULTS WITH AORTIC BALL VALVE PROSTHESES (STARR-EDWARDS) FOLLOWED FOR 2 TO 3 YEARS
    BJORK, VO
    CULLHED, I
    [J]. THORAX, 1967, 22 (01) : 21 - &
  • [42] Excellent Durability of a Starr-Edwards Mitral Caged-Ball-Valve Prosthesis over 34 Years
    Mariscalco, Giovanni
    Cozzi, Giuseppe P.
    Gherli, Riccardo
    Sala, Andrea
    [J]. JOURNAL OF CARDIAC SURGERY, 2011, 26 (01) : 72 - 72
  • [43] PERIPHERAL EMBOLIZATION OF A STRUT 12 YEARS AFTER AORTIC-VALVE REPLACEMENT WITH A STARR-EDWARDS VALVE PROSTHESIS
    SCHELD, HH
    SCHLEPPER, M
    MULCH, J
    GORLACH, G
    HOGE, R
    HEHRLEIN, FW
    [J]. HERZ KREISLAUF, 1983, 15 (05): : 240 - 243
  • [44] Transcatheter aortic valve implantation in a patient with previous Starr-Edwards mitral valve prosthesis
    Rahman, Mohammed Shamim
    Roy, David
    Brecker, Stephen J.
    [J]. HEART, 2013, 99 (03) : 217 - 218
  • [45] 6-YEARS EXPERIENCE WITH CARDIAC-VALVE REPLACEMENT USING STARR-EDWARDS BALL-VALVE PROSTHESIS
    ASANO, KI
    WASHIO, M
    EGUCHI, S
    NAKAMURA, C
    TANAKA, M
    MOTOYAMA, N
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 1973, 14 (02): : 117 - 125
  • [46] COMPLICATIONS FOLLOWING DESTRUCTION OF CLOTH COVERING OF A STARR-EDWARDS AORTIC VALVE PROSTHESIS
    BORUCHOW, IB
    RAMSEY, HW
    WHEAT, MW
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1971, 62 (02): : 290 - &
  • [47] PREMATURE VALVE CLOSURE IN PATIENTS WITH A MITRAL STARR-EDWARDS PROSTHESIS AND AORTIC INCOMPETENCE
    AGNEW, TM
    CARLISLE, RC
    [J]. AUSTRALASIAN ANNALS OF MEDICINE, 1970, 19 (02): : 185 - &
  • [48] PREMATURE VALVE CLOSURE IN PATIENTS WITH A MITRAL STARR-EDWARDS PROSTHESIS AND AORTIC INCOMPETENCE
    AGNEW, TM
    CARLISLE, R
    [J]. BRITISH HEART JOURNAL, 1970, 32 (04): : 436 - &
  • [50] RESULTS OF VALVE-REPLACEMENT WITH CLOTH-COVERED STARR-EDWARDS BALL VALVE PROSTHESIS
    VALTY, J
    SAGNES, JY
    ROZENSZTAJN, L
    GAUDEUL, P
    BICKERT, P
    MOTEBASSEM, R
    DUMOULIN, P
    MAURICE, P