DECENTRATION OF THE POSTERIOR CHAMBER LENS IMPLANT - THE EFFECT OF OPTIC SIZE ON THE INCIDENCE OF VISUAL ABERRATIONS

被引:17
|
作者
MCDONNELL, PJ
SPALTON, DJ
FALCON, MG
机构
关键词
D O I
10.1038/eye.1990.17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Intraocular lens implant components such as dialling holes can cause disabling symptoms when decentration of the implant places these components in the pupil. In order to investigate the importance of optic size in this context, we studied two groups of consecutive patients who had undergone cataract surgery: One group had received an implant with a 6 mm diameter optic, and the other an implant with a 7 mm diameter optic. We found that there was a significantly higher incidence of implant components such as dialling holes in the pupil in the 6 mm group when compared to the 7 mm group. The incidence of symptoms such as monocular diplopia and glare was marginally but not significantly higher in the 6 mm group. To minimise the risks of symptoms related to dialling holes in the pupil we recommend an implant design that has a large optical clear zone of at least 6 mm. © 1989, College of Ophthalmologists. All right reserved.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 50 条
  • [41] Safety and visual outcomes following posterior chamber phakic intraocular lens bilensectomy
    Veronica Vargas
    Jorge L. Alió
    Rafael I. Barraquer
    Justin Christopher D’ Antin
    Cristina García
    Francisco Duch
    Joan Balgos
    Jorge L. Alió del Barrio
    [J]. Eye and Vision, 7
  • [42] Tilt, Decentration, and Internal Higher-Order Aberrations of Sutured Posterior-Chamber Intraocular Lenses in Patients with Open Globe Injuries
    Zhu, Xiangjia
    Zhang, Yinglei
    He, Wenwen
    Ye, Hongfei
    Jiang, Chunhui
    Lu, Yi
    [J]. JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [43] Posterior continuous curvilinear capsulorhexis with and without optic capture of the posterior chamber intraocular lens in the absence of vitrectomy - Reply
    Raina, UK
    Gupta, V
    Arora, R
    Mehta, DK
    [J]. JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2003, 40 (03) : 131 - 131
  • [44] Effect of decentration on the quality of vision in two aspheric posterior chamber intraocular lenses: A contralateral eye study
    Thakur, Anchal
    Adiga, Sushant
    Malhotra, Chintan
    Sachdeva, Kulbhushan
    Singh, Shubhi
    Jain, Arun Kumar
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (04) : 558 - 564
  • [45] Influence on posterior capsule opacification and visual function of Intraocular lens optic material
    Hayashi, Ken
    Hayashi, Hideyuki
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (02) : 195 - 202
  • [46] Ab-interno scleral suture loop fixation with cow-hitch knot in posterior chamber intraocular lens decentration
    Can, Ertugrul
    Kocak, Nurullah
    Yucel, Ozlem Eski
    Gul, Adem
    Ozturk, Hilal Eser
    Sayin, Osman
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (02) : 124 - 126
  • [47] INCIDENCE OF RETINAL-DETACHMENT FOLLOWING POSTERIOR CHAMBER INTRAOCULAR-LENS SURGERY
    KRAFF, MC
    SANDERS, DR
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04): : 477 - 480
  • [48] Incidence of cystoid macular edema following secondary posterior chamber intraocular lens implantation
    Meyer, Linda M.
    Philipp, Sebastian
    Fischer, Marie T.
    Distelmaier, Peter
    Paquet, Patrick
    Graf, Natascha E.
    Haritoglou, Christos
    Schoenfeld, Carl-Ludwig
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (09): : 1860 - 1866
  • [49] FACTORS INFLUENCING THE FORMATION OF POSTERIOR CAPSULAR OPACITIES AFTER EXTRACAPSULAR CATARACT-EXTRACTION WITH POSTERIOR CHAMBER LENS IMPLANT
    WESTLING, AK
    CALISSENDORFF, BM
    [J]. ACTA OPHTHALMOLOGICA, 1991, 69 (03): : 315 - 320
  • [50] Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification
    Buehl, W
    Findl, O
    Menapace, R
    Rainer, G
    Sacu, S
    Kiss, B
    Petternel, V
    Georgopoulos, M
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07): : 1105 - 1111