MONTE-CARLO SIMULATION OF TRANSMISSION STUDIES USING A PLANAR SOURCE WITH A PARALLEL COLLIMATOR AND A LINE SOURCE WITH A FAN-BEAM COLLIMATOR

被引:8
|
作者
LJUNGBERG, M [1 ]
STRAND, SE [1 ]
RAJEEVAN, N [1 ]
KING, MA [1 ]
机构
[1] UNIV MASSACHUSETTS,MED CTR,WORCESTER,MA 01605
关键词
D O I
10.1109/23.322952
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A knowledge of the distribution of the attenuation coefficient is generally required for a successful correction of attenuation in nonhomogeneous regions. This can be accomplished by performing transmission measurement with either parallel or fan-bean collimation. The Monte Carlo method makes it possible to fully evaluate the results of such a correction. This study shows results from such simulations for both parallel and fan-beam transmission imaging. Also, examples of the effect of down-scatter from an emission Tc-99m radionuclide into the energy window for a transmission Gd-153 radionuclide are shown.
引用
收藏
页码:1577 / 1584
页数:8
相关论文
共 50 条
  • [21] Collimator design for neutron radiography station using Monte Carlo simulation
    Wonglee, S.
    Liamsuwan, T.
    Pornroongruengchok, W.
    Channuie, J.
    Picha, R.
    Khaweerat, S.
    [J]. SIAM PHYSICS CONGRESS 2018 (SPC2018): A CREATIVE PATH TO SUSTAINABLE INNOVATION, 2018, 1144
  • [22] Accurate modeling of fan-beam collimators in brain SPECT imaging using Monte Carlo simulation
    Cot, A
    Sempau, J
    Pareto, D
    Bullich, S
    Pavía, J
    Calviño, F
    Ros, D
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1306 - 1308
  • [23] SIMULTANEOUS TRANSMISSION/EMISSION TOMOGRAPHY USING A LINE SOURCE WITH AN OFF-CENTER FANBEAM COLLIMATOR
    FICARO, EP
    HAWMAN, EG
    SCHWAIGER, M
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P191 - P191
  • [24] FAN-BEAM RECONSTRUCTION FROM A STRAIGHT-LINE OF SOURCE POINTS
    SMITH, BD
    SINGH, T
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (01) : 10 - 18
  • [25] Optimization of pinhole collimator for small animal SPECT using Monte Carlo simulation
    Song, TY
    Choi, Y
    Chung, YH
    Jung, JH
    Choe, YS
    Lee, KH
    Kim, SE
    Kim, BT
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 327 - 332
  • [26] Optimization of pinhole collimator for small animal SPECT using Monte Carlo simulation
    Song, TY
    Choi, Y
    Chung, YH
    Jung, JH
    Choe, YS
    Lee, KH
    Kim, SE
    Kim, BT
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 811 - 815
  • [27] Evaluation of the geometric, scatter, and septal penetration components in fan-beam collimators using Monte Carlo simulation
    Cot, A
    Sempau, J
    Pareto, D
    Bullich, S
    Pavía, J
    Calviño, F
    Ros, D
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 12 - 16
  • [28] Monte-Carlo simulation of electron beam collimation using parallel magnetic fields
    Groeneveld, Jacob
    Kirkby, Charles
    [J]. MEDICAL PHYSICS, 2022, 49 (08) : 5629 - 5629
  • [29] Optimization of a High-resolution Collimator for a CdTe Detector: Monte Carlo Simulation Studies
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Cho, Hyo-Min
    Lee, Seung-Wan
    Choi, Yu-Na
    Kim, Hee-Joung
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (05) : 862 - 868
  • [30] Optimization of a high-resolution collimator for a CdTe detector: Monte Carlo simulation studies
    Young-Jin Lee
    Hyun-Ju Ryu
    Hyo-Min Cho
    Seung-Wan Lee
    Yu-Na Choi
    Hee-Joung Kim
    [J]. Journal of the Korean Physical Society, 2012, 60 : 862 - 868