Impact of climate change on ventilation load and energy use of air conditioning systems in buildings of Hong Kong

被引:8
|
作者
Qi, Ronghui [1 ]
Lu, Lin [1 ]
Yang, Hongxing [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Renewable Energy Res Grp, Kowloon, Hong Kong, Peoples R China
关键词
ventilation load; sensible load; latent load; climate warming; urban heat island effect;
D O I
10.1093/ijlct/cts044
中图分类号
O414.1 [热力学];
学科分类号
摘要
Climate change may seriously affect the energy consumption of buildings by influencing their air conditioning loads, especially the ventilation loads which vary directly with the local weather conditions. Research on how the ventilation load responds to climate change is of great significance, especially in coastline subtropical regions like Hong Kong. This paper investigated the impacts of climate change on buildings' ventilation load and building energy use in Hong Kong with the hourly meteorological data from 1950 to 2007. Results have been well validated by the simulation of a typical local hotel building during this period. The results show that climate warming increases both sensible and latent parts of the cooling ventilation load. The latent part, which occupies similar to 80% of the total ventilation load, increases at a higher rate, about twice of that of the sensible one. Furthermore, it is found that the urban heat island (UHI) effect causes a much higher growth rate of the ventilation load at night, which is about three times compared with that in the daytime. The latent part of the cooling ventilation load at night, which is found to be the most sensitive component to the climate change, plays a most significant role in the energy consumption increase. The possible measures were thus suggested to avoid negative changes of the ventilation load. Besides, reducing the UHI effect by better urban planning also significantly benefits the local buildings with a long air-conditioning operation time.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 50 条
  • [21] A discussion on potentials of saving energy use for commercial buildings in Hong Kong
    Yu, Philip C. H.
    Chow, W. K.
    ENERGY, 2007, 32 (02) : 83 - 94
  • [22] Use of electrical energy in university buildings: a Hong Kong case study
    Wong, W.
    Fellows, R.
    Liu, A.
    FACILITIES, 2006, 24 (1-2) : 5 - +
  • [23] Experience of energy auditing on a central air-conditioning plant in Hong Kong
    Hong Kong Polytechnic Univ, Kowloon, Hong Kong
    Energy Eng, 2 (6-30):
  • [24] Simulation of energy use for single-compartment buildings in Hong Kong
    Chow, WK
    Fong, SK
    APPLIED ENERGY, 1997, 57 (01) : 37 - 44
  • [25] Building energy performance of air-conditioned office buildings in Hong Kong
    Chan, RYC
    Lam, JC
    Li, DHW
    Tsang, EKW
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 985 - 992
  • [26] Survey of design considerations for ventilating and air-conditioning systems in Hong Kong
    Chow, WK
    Fung, WY
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 2, 1996, 102 : 210 - 219
  • [28] Partial ice-storage: Application to air conditioning systems in Hong Kong
    Yang, Hongxing
    You, Shijun
    Building Services Engineering Research and Technology, 1999, 20 (04): : 201 - 203
  • [29] Retrofitting low-cost heating ventilation and air-conditioning systems for energy management in buildings
    Rashid, Syed Aftab
    Haider, Zeeshan
    Hossain, S. M. Chapal
    Memon, Kashan
    Panhwar, Fazil
    Mbogba, Momoh Karmah
    Hu, Peng
    Zhao, Gang
    APPLIED ENERGY, 2019, 236 : 648 - 661
  • [30] Climate change impact on energy savings in mixed-mode ventilation office buildings in Brazil
    Veloso, A. C. O.
    Souza, R. V. G.
    ENERGY AND BUILDINGS, 2024, 318