A CLINICAL-EVALUATION OF THE OPTEC INLAY SYSTEM

被引:20
|
作者
MOLIN, M [1 ]
KARLSSON, S [1 ]
机构
[1] GOTHENBURG UNIV,FAC ODONTOL,DEPT PROSTHET DENT,S-41124 GOTHENBURG,SWEDEN
关键词
CERAMIC INLAYS; CLINICAL EXAMINATION; PORCELAIN;
D O I
10.3109/00016359209012767
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To evaluate the clinical quality of ceramic (Optec) inlays, the inlay production of 10 dentists, se-ed by 3 dental laboratories, was examined independently by 2 calibrated examiners. A total of 57 patients with 205 inlays (mean age, 8.1 months) were examined 1 to 32 months after placement by means of using a slightly modified form of the California Dental Association criteria. Periodontal variables such as plaque index, gingival index, and margin index were also recorded. Eight patients reported postoperative but not persistent hypersensitivity in relation to the Optec therapy. No differences between Optec proximal surfaces and homologous control surfaces were seen with regard to plaque or bleeding on probing. The examination using the CDA criteria showed that 59% of the inlays had a slight color mismatch. Slightly roughened surfaces were most common (86%). As to anatomic form and margin integrity, 24% and 67%, respectively, of the inlays were rated excellent. A difference between the dentist with regard to the clinical quality of the inlay treatment procedure was seen. The present results cannot allow a definitive judgement with regard to the long-term clinical quality of the Optec inlay system but will serve as a base for further studies.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 50 条
  • [21] DEVELOPMENT AND CLINICAL-EVALUATION OF A VERAPAMIL TRANSDERMAL DELIVERY SYSTEM
    SHAH, HS
    TOJO, K
    HUANG, YC
    CHIEN, YW
    JOURNAL OF CONTROLLED RELEASE, 1992, 22 (02) : 125 - 131
  • [22] DEVELOPMENT OF A SYSTEM FOR CLINICAL-EVALUATION OF THE BIOTIN STATUS OF SOWS
    MISIR, R
    BLAIR, R
    DOIGE, CE
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 1986, 27 (01): : 6 - 12
  • [23] CLINICAL-EVALUATION OF AN AUTOMATED-SYSTEM FOR DIALYZER REUSE
    FITZCHARLES, N
    ELLIOTT, HL
    MACDOUGALL, AI
    DIALYSIS & TRANSPLANTATION, 1980, 9 (09) : 825 - 828
  • [24] CLINICAL-EVALUATION OF A COMPUTERIZED DIALYSATE-DELIVERY SYSTEM
    GENTILE, DE
    KIDNEY INTERNATIONAL, 1980, 18 : S44 - S49
  • [25] CLINICAL-EVALUATION OF AN IMPROVED INJECTABLE MICROCAPSULE CONTRACEPTIVE SYSTEM
    BECK, LR
    FLOWERS, CE
    POPE, VZ
    WILBORN, WH
    TICE, TR
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1983, 147 (07) : 815 - 821
  • [26] CLINICAL-EVALUATION OF LVAD
    TAKANO, H
    NAKATANI, T
    FUJITA, T
    AKUTSU, T
    MANABE, H
    ARTIFICIAL ORGANS, 1988, 12 (05) : 462 - 462
  • [27] CLINICAL-EVALUATION OF OLFACTION
    CAIN, WS
    GENT, J
    CATALANOTTO, FA
    GOODSPEED, RB
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 1983, 4 (04) : 252 - 256
  • [28] CLINICAL-EVALUATION OF DEMENTIA
    KOBLENZER, J
    MOUNT SINAI JOURNAL OF MEDICINE, 1993, 60 (06): : 532 - 538
  • [29] CLINICAL-EVALUATION OF THE SHOULDER
    JESSNER, A
    ORTHOPADE, 1995, 24 (06): : 475 - 482
  • [30] CLINICAL-EVALUATION OF CLORAZEPATE
    GUGGENHEIM, MA
    DONALDSON, J
    HOTVEDT, C
    ANNALS OF NEUROLOGY, 1987, 22 (03) : 412 - 413