RADON TRANSPORT IN A DRILLED WELL STUDIED BY ETCHED TRACK TYPE RADON MONITORS

被引:4
|
作者
CSIGE, I
HAKL, J
VASARHELYI, A
HUNYADI, I
机构
[1] Institute of Nuclear Research, the Hungarian Academy of Sciences, H-4001 Debrecen
关键词
CR-39 TRACK ETCH DETECTOR; RADON; RADON IN WATER; CARBON DIOXIDE; VACUUM EFFECT;
D O I
10.1016/1350-4487(95)00184-G
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We have measured the radon concentration profile along a 20 meter deep drilled well with etched track type radon monitors. The well has a diameter of 12. cm. It has water at 11.6 meter below the surface and exhales nearly 100% carbon dioxide of geological origin at rate of about 300 liters/hour. We made radon measurements both underwater and in the gaseous atmosphere. Radon transport models (such as microbubble, macrobubble, eddy diffusion, etc.) were tested to find the best fit to experimental radon profiles. The measuring site is at a geologically active area, and the effect of a small earthquake on the exhalation rate of CO2 from the well was also observed.
引用
收藏
页码:561 / 564
页数:4