AN AMPEROMETRIC LACTATE SENSOR EMPLOYING TETRATHIAFULVALENE IN NAFION FILM AS ELECTRON SHUTTLE

被引:41
|
作者
LIU, HY [1 ]
DENG, JQ [1 ]
机构
[1] FUDAN UNIV,DEPT CHEM,SHANGHAI 200433,PEOPLES R CHINA
关键词
TETRATHIAFULVALENE; L-LACTATE; LACTATE OXIDASE; NAFION; SENSOR;
D O I
10.1016/0013-4686(95)00099-Z
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The development of an amperometric sensor utilizing tetrathiafulvalene (TTF) as an electron shuttle between immobilized lactate oxidase and a glassy carbon electrode is described. The problem of mediator leaking in electrodes using TTF is overcome by employing Nafion membrane that prevents leaching of positive TTF+ ions by electrostatic attraction. Stability, interference, and the factors such as oxygen, applied potential, and pH influencing the performance of the lactate sensor are examined and discussed. The response of the sensor to lactate under N-2 saturation reaches 95% steady-state current within 40s.
引用
收藏
页码:1845 / 1849
页数:5
相关论文
共 50 条
  • [1] AMPEROMETRIC GLUCOSE SENSOR USING TETRATHIAFULVALENE IN NAFION GEL AS ELECTRON SHUTTLE
    LIU, HY
    DENG, JQ
    ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) : 65 - 70
  • [2] AN AMPEROMETRIC LACTATE SENSOR USING TETRATHIAFULVALENE IN POLYESTER IONOMER FILM AS ELECTRON-TRANSFER
    LIU, HY
    KONG, JL
    DENG, JQ
    ANALYTICAL LETTERS, 1995, 28 (04) : 563 - 579
  • [3] Amperometric Glucose Sensor with Tetrathiafulvalene as an Electron Transfer Mediator
    SUN Changqing YANG Xu LUAN Chaixia GAO Qian and XU HongdingDepartment of Cheniistry Jilin University Changchun
    ChemicalResearchinChineseUniversities, 1995, (03)
  • [4] Amperometric glucose sensor with tetrathiafulvalene as an electron transfer mediator
    Sun, Chang-qing
    Yang, Xu
    Luan, Chai-xia
    Gao, Qian
    Xu, Hong-ding
    Chemical Research in Chinese Universities, 1995, 11 (03)
  • [5] AMPEROMETRIC GLUCOSE SENSOR WITH TETRATHIAFULVALENE AS AN ELECTRON-TRANSFER MEDIATOR
    SUN, CQ
    YANG, X
    LUAN, CX
    GAO, Q
    XU, HD
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 1995, 11 (03): : 189 - 194
  • [6] Nafion based amperometric hydrogen sensor
    G. Velayutham
    C. Ramesh
    N. Murugesan
    V. Manivannan
    K. S. Dhathathreyan
    G. Periaswami
    Ionics, 2004, 10 : 63 - 67
  • [7] Nafion based amperometric hydrogen sensor
    Velayutham, G
    Ramesh, C
    Murugesan, N
    Manivannan, V
    Dhathathreyan, KS
    Periaswami, G
    IONICS, 2004, 10 (1-2) : 63 - 67
  • [8] Novel electron transfer mediators, indoaniline derivatives for amperometric lactate sensor
    Hirano, K
    Yamato, H
    Kunimoto, K
    Ohwa, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 86 (01) : 88 - 93
  • [9] Studies on employing tetrathiafulvalene as an electron shuttle incorporated in a montmorillonite-modified immobilization matrix for an enzyme electrode
    Lei, CH
    Zhang, ZE
    Liu, HY
    Deng, JQ
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 419 (01): : 93 - 98
  • [10] An amperometric biosensor based on immobilised glucose oxidase employing p-benzoquinone as electron shuttle
    Qian, JH
    Liu, YC
    Liu, HY
    Yu, TY
    Deng, JQ
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 1996, 67 (03) : 281 - 285