PERFORMANCE ANALYSIS OF THE TNO TLD INDIVIDUAL MONITORING SERVICE

被引:0
|
作者
VANDIJK, JWE
JULIUS, HW
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this study was to analyse the performance and to establish the lowest detectable occupational dose (LDOD) of the TNO TL dosemeter, in use for large scale routine individual monitoring since 1983. The TNO individual monitoring service uses three TLD reader systems and over 45000 TL dosemeters, designed to measure H(s)(0.07) and H(p)(10). Each reader system is normalised daily and each individual dosemeter is calibrated every ten readout cycles. The performance of the service is monitored by a double blind experimental set-up. A series of 10 routine dosemeters is issued every fortnight, mailed, exposed by staff not involved in the monitoring service, sent back and evaluated. The conclusion of this study is that the lowest detectable occupational dose is less than 0.04 mSv and that the integrated dose at the level of the annual dose limit is measured within 2%.
引用
收藏
页码:171 / 174
页数:4
相关论文
共 50 条
  • [11] OVERVIEW OF THE QUALITY ASSURANCE PROGRAMME IMPLEMENTED FOR TLD BASED INDIVIDUAL MONITORING IN INDIA
    Srivastava, Kshama
    Bakshi, A. K.
    Punekar, M. P.
    Kolambe, D. H.
    Ratna, P.
    Datta, D.
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 174 (02) : 175 - 184
  • [12] Brazilian two-component TLD albedo neutron individual monitoring system
    Martins, M. M.
    Mauricio, C. L. P.
    da Fonseca, E. S.
    da Silva, A. X.
    [J]. RADIATION MEASUREMENTS, 2010, 45 (10) : 1509 - 1512
  • [13] TNO Monitoring plan development tool
    Sijacic, Danijela
    Wildenborg, Ton
    Steeghs, Philippe
    [J]. 12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 4834 - 4840
  • [14] ENVIRONMENTAL MONITORING WITH TLD
    BECKER, K
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (02): : 405 - &
  • [15] TLD PATIENT MONITORING
    HUDSON, FR
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (710): : 205 - 205
  • [16] Implementation of quality standards in an individual monitoring service
    Hyvönen, H
    Vartiainen, E
    [J]. RADIATION PROTECTION DOSIMETRY, 2001, 96 (1-3) : 117 - 122
  • [17] Seven years of individual monitoring service in Cuba
    Suarez, RC
    Bernal, EDD
    Bejerano, GML
    Sed, LAJ
    [J]. IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D201 - D203
  • [18] 10-YEARS EXPERIENCE WITH A LARGE COMPUTERIZED TLD-PERSONNEL MONITORING SERVICE
    DUFTSCHMID, KE
    [J]. ACTA PHYSICA HUNGARICA, 1986, 59 (1-2) : 189 - 192
  • [19] TLD SYSTEM FOR RADIOTHERAPY MONITORING
    DALGLEISH, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (03): : 465 - 467
  • [20] A TLD system for environmental monitoring
    Prokic, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 153 - 156