CEREBROSPINAL-FLUID FLOW MEASURED BY PHASE-CONTRAST CINE MR

被引:1
|
作者
ENZMANN, DR
PELC, NJ
机构
关键词
CEREBROSPINAL FLUID; FLOW DYNAMICS; MAGNETIC RESONANCE; FLOW STUDIES;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PURPOSE: This prospective study was designed to establish the temporal and quantitative relationship between blood flow and cerebrospinal fluid (CSF) flow using a phase-contrast cine MR pulse sequence. METHODS: A cine phase-contrast MR pulse sequence using peripheral gating was used to measure CSF flow direction and velocity. Data were acquired continuously and interpolated into 16 images throughout the cardiac cycle. RESULTS: The timing of systolic CSF flow in the cervical subarachnoid space (SAS) correlated very closely to the brain arteriovenous blood flow difference during the cardiac cycle. This arteriovenous difference was a measure of brain expansion. Aqueduct CSF flow during the cardiac cycle differed from SAS flow in that systolic flow was delayed in comparison with systolic cervical SAS flow. The normal aqueductal oscillatory flow volume was 1.7 +/- .4 mL/min or 0.03 +/- 0.01 mL per cardiac cycle. This represented 14.5% +/- 3.1 % of the total CSF flow and tissue displacement through the incisura which was 14.5 +/- 2.2 mL/min or 0.22 +/- 0.03 mL per cycle. CSF oscillatory flow volume in the cervical SAS was 39.0 +/- 4.0 mL/min or 0.65 +/- 0.08 mL per cycle. CONCLUSION: CSF flow can be measured. Results in healthy subjects show relatively low oscillatory flow through the aqueduct which is slightly out of phase (delayed) compared with SAS CSF flow.
引用
收藏
页码:1301 / 1307
页数:7
相关论文
共 50 条
  • [41] TRACKING OF CYCLIC MOTION WITH PHASE-CONTRAST CINE MR VELOCITY DATA
    PELC, NJ
    DRANGOVA, M
    PELC, LR
    ZHU, Y
    NOLL, DC
    BOWMAN, BS
    HERFKENS, RJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 339 - 345
  • [42] VALIDATION OF CINE PHASE-CONTRAST MR-IMAGING FOR MOTION ANALYSIS
    LINGAMNENI, A
    HARDY, PA
    POWELL, KA
    PELC, NJ
    WHITE, RD
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 331 - 338
  • [43] RUPTURED SINUS OF VALSALVA ANEURYSM - CINE PHASE-CONTRAST MR CHARACTERIZATION
    HO, VB
    KINNEY, JB
    SAHN, DJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (04) : 652 - 656
  • [45] Blood and cerebrospinal fluid flow oscillations measured with real-time phase-contrast MRI: breathing mode matters
    Lagana, Maria Marcella
    Di Tella, Sonia
    Ferrari, Francesca
    Pelizzari, Laura
    Cazzoli, Marta
    Alperin, Noam
    Jin, Ning
    Zaca, Domenico
    Baselli, Giuseppe
    Baglio, Francesca
    FLUIDS AND BARRIERS OF THE CNS, 2022, 19 (01)
  • [46] Cerebrospinal fluid flow in empty sella syndrome and normal sellar regions measured by phase-contrast quantitative magnetic resonance
    Hu, Weidong
    Xiang, Li
    Wang, Xiurong
    NEURAL REGENERATION RESEARCH, 2011, 6 (11) : 816 - 820
  • [47] Normal values for cerebrospinal fluid flow dynamics in the aqueduct of Sylvius through optimized analysis of phase-contrast MR images
    Florez, N.
    Marti-Bonmati, L.
    Forner, J.
    Arana, E.
    Moratal, D.
    RADIOLOGIA, 2009, 51 (01): : 38 - 44
  • [48] Phase-contrast cine MR angiography detection of thoracic aortic dissection
    Jeffrey M. Silverman
    Sharo Raissi
    J. Michael Tyszka
    Alfredo Trento
    Robert J. Herfkens
    The International Journal of Cardiac Imaging, 2000, 16 : 461 - 470
  • [49] Phase-contrast cine MR angiography detection of thoracic aortic dissection
    Silverman, JM
    Raissi, S
    Tyszka, JM
    Trento, A
    Herfkens, RJ
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (06): : 461 - 470
  • [50] Evaluation of cerebrospinal fluid flow dynamic changes in patients with idiopathic intracranial hypertension using phase contrast cine MR imaging
    Belal, Tamer
    Al Tantawy, Abd-Elhalim
    Sherif, Fatema Mohamed
    Ramadan, Alshaimaa
    EGYPTIAN JOURNAL OF NEUROLOGY PSYCHIATRY AND NEUROSURGERY, 2020, 56 (01):