Poly (xylenol orange) film-coated graphite pencil electrode was fabricated for the detection of dopamine in the presence of ascorbic acid and uric acid in phosphate buffer solution of pH 7. The redox peaks obtained at modified electrode shows a good enhancement. The scan rate effect was found to be a diffusion-controlled electrode process. The electrochemical oxidation of dopamine was depended on pH, and the limit of detection was found to be 9.1 x 10(-8) M. The simultaneous study gave and excellent result with great potential difference between dopamine and other bioactive organic molecules by using both cyclic voltammetric and differential pulse voltammetric techniques. The present modified graphite electrode was applied to the detection of dopamine in the injection samples, and the recovery obtained was satisfactory.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Polyelectrolyte Multilayer Film-Coated Electrodes for Amperometric Determination of Hydrogen Peroxide in the Presence of Ascorbic Acid, Uric Acid and Acetaminophen
    Tomonori Hoshi
    Hidekazu Saiki
    Sachie Kuwazawa
    Yuka Kobayashi
    Jun-Ichi Anzai
    Analytical Sciences, 2000, 16 : 1009 - 1010
  • [32] Selective Detection of Uric Acid in the Presence of Ascorbic Acid and Dopamine Using Polymerized Luminol Film Modified Glassy Carbon Electrode
    Kumar, S. Ashok
    Cheng, Hui-Wen
    Chen, Shen-Ming
    ELECTROANALYSIS, 2009, 21 (20) : 2281 - 2286
  • [33] Simultaneous voltammetric detection of dopamine, ascorbic acid and uric acid using a poly(2-(Nmorpholine) ethane sulfonic acid)/RGO modified electrode
    Zhang, Keying
    Zhang, Na
    Zhang, Li
    Wang, Hongyan
    Shi, Hongwei
    Liu, Qiao
    RSC ADVANCES, 2018, 8 (10): : 5280 - 5285
  • [34] Polyelectrolyte multilayer film-coated electrodes for amperometric determination of hydrogen peroxide in the presence of ascorbic acid, uric acid and acetaminophen
    Hoshi, T
    Saiki, H
    Kuwazawa, S
    Kobayashi, Y
    Anzai, J
    ANALYTICAL SCIENCES, 2000, 16 (10) : 1009 - 1010
  • [35] Determination of uric acid in the presence of dopamine on the activated pencil lead electrode
    Majidi, MR
    Danandeh-Jenagharad, M
    ASIAN JOURNAL OF CHEMISTRY, 2005, 17 (04) : 2165 - 2174
  • [36] Poly(4-vinylpyridine)-coated chemically modified electrode for the detection of uric acid in the presence of a high concentration of ascorbic acid
    Zen, JM
    Chen, YJ
    Hsu, CT
    Ting, YS
    ELECTROANALYSIS, 1997, 9 (13) : 1009 - 1013
  • [37] Electrocatalytic oxidation and voltammetric determination of ciprofloxacin employing poly(alizarin red)/graphene composite film in the presence of ascorbic acid, uric acid and dopamine
    Zhang, Xin
    Wei, Youli
    Ding, Yaping
    ANALYTICA CHIMICA ACTA, 2014, 835 : 29 - 36
  • [38] Clay modified carbon paste electrode for the voltammetric detection of dopamine in presence of ascorbic acid
    Sathisha, Tammanekar V.
    Swamy, Bahaddurghatta E. Kumara
    Reddy, Sathish
    Chandrashekar, Bananakere N.
    Eswarappa, Bheemappa
    JOURNAL OF MOLECULAR LIQUIDS, 2012, 172 : 53 - 58
  • [39] Selective voltammetric detection of uric acid in the presence of ascorbic acid at well-aligned carbon nanotube electrode
    Ye, JS
    Wen, Y
    De Zhang, W
    Gan, LM
    Xu, GQ
    Sheu, FS
    ELECTROANALYSIS, 2003, 15 (21) : 1693 - 1698
  • [40] Glassy carbon electrode modified with poly(dibromofluorescein) for the selective determination of dopamine and uric acid in the presence of ascorbic acid
    Wang, Yan
    Xiao, Yan
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 123 - 130