INFLUENCE OF TOPICAL ANESTHESIA ON TONOMETRIC VALUES OF INTRAOCULAR-PRESSURE

被引:41
|
作者
BAUDOUIN, C
GASTAUD, P
机构
[1] Department of Ophthalmology, Saint-Roch Hospital, F-06006 Nice Cedex 1
关键词
AIR PULSE; TONOMETER; ANESTHETICS; GLAUCOMA; APPLANATION TONOMETRY; INTRAOCULAR PRESSURE;
D O I
10.1159/000310527
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The air pulse noncontact tonometer provides a safe and reliable method for measuring intraocular pressure (IOP), and makes it possible to avoid topical anesthesia. Based on previous reports that suggested possible anesthetic-induced IOP variations, this study was undertaken to investigate with this procedure the influence of local anesthetics on IOP and of some topically used drugs that could modify IOP values. In 212 normal or glaucomatous patients who underwent IOP measurement with a noncontact tonometer, IOP was determined before and in the first minutes following instillation of one of four tested drugs, oxybuprocaine and betoxycaine, two topical anesthetics currently used in applanation tonometry, and indomethacin suspension and metipranolol as controls. No significant effect was observed when comparing IOP values successively measured with the air pulse tonometer or 1 min after instillation of indomethacin suspension and metipranolol. In contrast a significant decrease in IOP was observed 1 and 5 min after instillation of one drop of the local anesthetics oxybuprocaine (mean IOP: 15.53 mm Hg before, 14.77 mm Hg at the 1st minute; p<0.001) and betoxycaine (16.06 mm Hg before, 15.70 mm Hg at the 1st minute; p = 0.023). This effect was observed at least to the 15th minute, and in some patients, the decrease in IOP reached 8 mm Hg. Metipranolol only decreased IOP significantly at the 15th minute as compared to initial values, which differed from IOP variations following topical anesthesia. This phenomenon could not be related to mechanical effects of repetitive IOP measurements or massage by eyelids secondary to corneal irritation by anesthetic eye drops. The observed effect was a slight but significant and almost constant decrease of IOP in the first minutes following topical anesthesia, as used in applanation tonometry. Although its mechanisms remain to be determined, it could thus result in an underestimation of IOP when using classical tonometric procedures.
引用
收藏
页码:309 / 313
页数:5
相关论文
共 50 条
  • [31] EFFECT ON THE INTRAOCULAR-PRESSURE OF HYPOTENSIVE ANESTHESIA WITH INTRAVENOUS TRIMETAPHAN
    DIAS, PLR
    ANDREW, DS
    ROMANES, GJ
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1982, 66 (11) : 721 - 724
  • [32] INTRAOCULAR-PRESSURE CHANGES DURING HALOTHANE AND ENFLURANE ANESTHESIA
    RUNCIMAN, JC
    BOWENWRIGHT, RM
    WELSH, NH
    DOWNING, JW
    BRITISH JOURNAL OF ANAESTHESIA, 1978, 50 (04) : 371 - 374
  • [33] THE EFFECT OF DIFFERENT METHODS OF INDUCING ANESTHESIA ON INTRAOCULAR-PRESSURE
    BADRINATH, SK
    VAZEERY, A
    MCCARTHY, RJ
    IVANKOVICH, AD
    ANESTHESIOLOGY, 1986, 65 (04) : 431 - 435
  • [34] INFLUENCE OF VASODILATATORS ON INTRAOCULAR-PRESSURE AND BLOOD-PRESSURE
    STEINBACH, PD
    BELL, H
    ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1977, 202 (03): : 213 - 222
  • [35] INTRAOCULAR-PRESSURE
    CHENG, TO
    POSTGRADUATE MEDICAL JOURNAL, 1991, 67 (791) : 856 - 857
  • [36] EFFECT ON INTRAOCULAR-PRESSURE OF LOCAL-ANESTHESIA IN EYES UNDERGOING INTRAOCULAR SURGERY
    ODONOGHUE, E
    BATTERBURY, M
    LAVY, T
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1994, 78 (08) : 605 - 607
  • [37] IDENTIFICATION OF HIGH INTRAOCULAR-PRESSURE RESPONDERS TO TOPICAL OPHTHALMIC CORTICOSTEROIDS
    BARTLETT, JD
    WOOLLEY, TW
    ADAMS, CM
    JOURNAL OF OCULAR PHARMACOLOGY, 1993, 9 (01): : 35 - 45
  • [38] THYROID-FUNCTION AND INTRAOCULAR-PRESSURE RESPONSE TO TOPICAL CORTICOSTEROIDS
    KRUPIN, T
    JACOBS, LS
    PODOS, SM
    BECKER, B
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1977, 83 (05) : 643 - 646
  • [39] THE INTERRELATIONSHIP BETWEEN INTRAOCULAR-PRESSURE AND HONAN INTRAOCULAR-PRESSURE REDUCER PRESSURE
    GREEN, K
    HARMAN, D
    CHEEKS, L
    CURRENT EYE RESEARCH, 1986, 5 (08) : 621 - 623
  • [40] INFLUENCE OF HEMODIALYSIS ON CORNEAL THICKNESS AND INTRAOCULAR-PRESSURE
    OLSEN, T
    SCHMITZ, O
    HANSEN, HE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1982, 181 (01) : 25 - 26