TECHNETIUM-99M-TETROFOSMIN MYOCARDIAL IMAGING - A COMPARISON WITH TL-201 AND ANGIOGRAPHY

被引:0
|
作者
RIGO, P
LECLERCQ, B
ITTI, R
LAHIRI, A
BRAAT, S
机构
[1] UNIV LIEGE,DEPT MED,DIV NUCL MED,LIEGE,BELGIUM
[2] NEUROCARDIOL HOSP,LYON,FRANCE
[3] NORTHWICK PK HOSP & CLIN RES CTR,HARROW HA1 3UJ,MIDDX,ENGLAND
[4] UNIV LIMBURG,ACAD HOSP MAASTRICHT,DEPT CARDIOL,6200 MD MAASTRICHT,NETHERLANDS
关键词
MYOCARDIAL PERFUSION IMAGING; CORONARY ANGIOGRAPHY; TL-201; TECHNETIUM-99M-TETROFOSMIN;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Images recorded after intravenous administration of Tc-99m-tetrofosmin were compared to those obtained with (TI)-T-201 in a series of 40 patients with angiographically documented coronary artery disease. These patients were part of a Phase II tetrofosmin study and presented anamnestic or laboratory evidence suggestive of ischemic heart disease. Methods: Thirty-seven patients had one or more coronary obstructions greater or equal to 70% of luminal diameter. Three patients studied after bypass surgery or angioplasty had patent grafts, absence of disease progression or no significant restenosis. Twenty-six patients had evidence of previous myocardial infarction. AII images were processed into a common display format by a core laboratory. They were identified by code and read by concensus of four investigators. Each segment was classified as normal or abnormal and these readings were combined and categorized into normal, reversible, fixed or mixed regional defects. Results: There was good segmental correspondence between thallium and tetrofosmin (kappa values ranged from 0.43 to 1.00). The ability of thallium and tetrofosmin to recognize and localize myocardial infarction was excellent, since corresponding abnormalities were present in respectively 24 and 25 of the 26 patients with previous myocardial infarction. Abnormalities in noninfarcted territories were recognized with both tracers in 16 of 28 patients presenting with coronary lesions involving Vessels unrelated to the infarct. Conclusion: In comparison to rest tetrofosmin, thallium redistribution shows more reversibility in areas with myocardial infarction but less reversibility in areas of myocardial ischemia. Current Phase II results suggest that tetrofosmin is a sensitive and reliable tracer for detecting myocardial infarction and ischemia. Results should be confirmed in a larger group of patients.
引用
收藏
页码:587 / 593
页数:7
相关论文
共 50 条
  • [21] Comparison of technetium-99m-MIBI and technetium-99m-tetrofosmin uptake by musculoskeletal sarcomas
    Soderlund, V
    Jonsson, C
    Bauer, HCF
    Brosjo, O
    Jacobsson, H
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 682 - 686
  • [22] CHOOSING A TL-201 OR TECHNETIUM 99M SESTAMIBI IMAGING PROTOCOL
    UDELSON, JE
    JOURNAL OF NUCLEAR CARDIOLOGY, 1994, 1 (05) : S99 - S108
  • [23] SPECT IMAGING OF GLIOMAS WITH TL-201 AND TECHNETIUM-99M-HMPAO
    SJOHOLM, H
    ELMQVIST, D
    REHNCRONA, S
    ROSEN, I
    SALFORD, LG
    ACTA NEUROLOGICA SCANDINAVICA, 1995, 91 (01): : 66 - 70
  • [24] COMPARISON OF TL-201 AND TECHNETIUM 99M-SESTAMIBI IN MYOCARDIAL INFUSION SCINTISCANS FOR THE DETECTION OF ASHD
    TAILLEFER, R
    LAMBERT, R
    GREGOIRE, J
    ESSIAMBRE, R
    PHANEUF, DC
    UNION MEDICALE DU CANADA, 1990, 119 (06): : 322 - &
  • [25] Technetium-99m-tetrofosmin imaging of lung cancer: Relationship with histopathology
    Takekawa, H
    Shinano, H
    Tsukamoto, E
    Koseki, Y
    Ikeno, T
    Miller, F
    Kawakami, Y
    ANNALS OF NUCLEAR MEDICINE, 1999, 13 (02) : 71 - 75
  • [26] MYOCARDIAL PERFUSION IMAGING WITH A NEW RADIOTRACER, TECHNETIUM-99M-HEXAMIBI (METHOXY ISOBUTYL ISONITRILE) - COMPARISON WITH TL-201 IMAGING
    TAILLEFER, R
    DUPRAS, G
    SPORN, V
    RIGO, P
    LEVEILLE, J
    BOUCHER, P
    PEREZBALINO, N
    CAMIN, LL
    MCKUSICK, KA
    CLINICAL NUCLEAR MEDICINE, 1989, 14 (02) : 89 - 96
  • [27] Technetium-99m-tetrofosmin imaging of lung cancer: Relationship with histopathology
    Hironori Takekawa
    Hideki Shinano
    Eriko Tsukamoto
    Yukio Koseki
    Toshiyuki Ikeno
    Fredrick Miller
    Yoshikazu Kawakami
    Annals of Nuclear Medicine, 1999, 13 : 71 - 75
  • [28] Uptake of technetium-99m-tetrofosmin, technetium-99m-MIBI and thallium-201 in tumor cell lines
    Arbab, AS
    Koizumi, K
    Toyama, K
    Araki, T
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (09) : 1551 - 1556
  • [29] PATHOPHYSIOLOGY OF MYOCARDIAL INFARCT SCINTIGRAPHY WITH TECHNETIUM-99M PYROPHOSPHATE, TECHNETIUM-99M DIPHOSPHONATE AND TL-201
    PARKEY, RW
    BUJA, LM
    TOFE, AJ
    STOKELY, EM
    BONTE, FJ
    WILLERSON, JT
    INVESTIGATIVE RADIOLOGY, 1976, 11 (05) : 395 - 395
  • [30] Technetium-99m-tetrofosmin for parathyroid scintigraphy: Comparison to thallium-technetium scanning
    Apostolopoulos, DJ
    Houstoulaki, E
    Giannakenas, C
    Alexandrides, T
    Spiliotis, J
    Nikiforidis, G
    Vlachojannis, JG
    Vassilakos, PJ
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (08) : 1433 - 1441