MEASURING THE PREDICTIVE PERFORMANCE OF COMPUTER-CONTROLLED INFUSION PUMPS

被引:414
|
作者
VARVEL, JR
DONOHO, DL
SHAFER, SL
机构
[1] UNIV CALIF BERKELEY,DEPT STAT,BERKELEY,CA 94720
[2] STANFORD UNIV,MED CTR,DEPT ANESTHESIA,STANFORD,CA 94305
来源
关键词
ANESTHESIA; COMPUTER-ASSISTED EQUIPMENT; INFUSION PUMP; PERFORMANCE PHARMACOKINETICS; PREDICTIVE PERFORMANCE;
D O I
10.1007/BF01143186
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Current measures of the performance of computer-controlled infusion pumps (CCIPs) are poorly defined, of little use to the clinician using the CCIP, and pharmacostatistically incorrect. We propose four measures be used to quantitate the performance of CCIPs: median absolute performance error (MDAPE), median performance error (MDPE), divergence, and wobble. These measures offer several significant advantages over previous measures. First, their definitions are based on the performance error as a fraction of the predicted (rather than measured) drug concentration, making the measures much more useful to the clinician. Second, the measures are defined in a way that addresses the pharmacostatistical issue of appropriate estimation of population parameters. Finally, the measure of inaccuracy, MDAPE, is defined in a way that is consistent with iteratively reweighted least squares nonlinear regression, a commonly used method of estimating pharmacokinetic parameters. These measures make it possible to quantitate the overall performance of a CCIP or to compare the predictive performance of CCIPs which differ in either general approach (e.g., compartmental model driven vs. plasma efflux approach), pump mechanics, software algorithms, or pharmacokinetic parameter sets.
引用
收藏
页码:63 / 94
页数:32
相关论文
共 50 条
  • [31] BLOOD-PRESSURE REGULATION BY COMPUTER-CONTROLLED INFUSION OF VASODILATORS
    HONIG, R
    SCHULZ, V
    LOESCHCKE, G
    BIOMEDIZINISCHE TECHNIK, 1985, 30 (06): : 134 - 138
  • [32] HYPERTENSIVE CRISIS MANAGED BY COMPUTER-CONTROLLED INFUSION OF SODIUM NITROPRUSSIDE
    HAMMOND, JJ
    KIRKENDALL, WM
    CIRCULATION, 1977, 56 (04) : 142 - 142
  • [33] The pharmacokinetics and hemodynamic effects of computer-controlled infusion of dexmedetomidine.
    Hsu, YW
    Cortinez, LI
    Somma, J
    JOURNAL OF CLINICAL PHARMACOLOGY, 2002, 42 (09): : 1065 - 1065
  • [34] Comparison of computer-controlled administration of propofol with two manually controlled infusion techniques
    Struys, M
    Versichelen, L
    Thas, O
    Herregods, L
    Rolly, G
    ANAESTHESIA, 1997, 52 (01) : 41 - 50
  • [35] Computer-controlled endoscopic performance assessment system
    G. B. Hanna
    T. Drew
    P. Clinch
    B. Hunter
    A. Cuschieri
    Surgical Endoscopy, 1998, 12 : 997 - 1000
  • [36] COMPUTER-CONTROLLED PERFORMANCE OF PHOTOACOUSTIC RESONANCE EXPERIMENTS
    KARBACH, A
    ROPER, J
    HESS, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (06): : 892 - 895
  • [37] Computer-controlled endoscopic performance assessment system
    Hanna, GB
    Drew, T
    Clinch, P
    Hunter, B
    Cuschieri, A
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1998, 12 (07): : 997 - 1000
  • [38] CRITERIA FOR USE OF COMPUTER-CONTROLLED LARGE SCALE MEASURING DEVICES
    SCHLIER, C
    CHEMIE INGENIEUR TECHNIK, 1970, 42 (13) : 867 - &
  • [39] A COMPUTER-CONTROLLED DIGITAL MEASURING SYSTEM FOR GEOELECTRICAL DEPTH SOUNDINGS
    FROHLICH, R
    ROSENBACH, O
    KELLER, F
    HORSTMEYER, H
    GEOPHYSICS, 1985, 50 (02) : 276 - 276
  • [40] COMPUTER-CONTROLLED FLEXIBLE MEASURING DEVICE FOR TESTING INTERNAL THREADS
    KAMPA, H
    KRING, J
    EDEL, S
    TECHNISCHES MESSEN, 1985, 52 (12): : 465 - 470