COMPARISON OF PROXIMAL AND DISTAL ONE PORTAL ENTRY TECHNIQUES FOR ENDOSCOPIC CARPAL-TUNNEL RELEASE - A CADAVER STUDY

被引:11
|
作者
TSURUTA, T [1 ]
SYED, SA [1 ]
TSAI, T [1 ]
机构
[1] CHRISTINE M KLEINERT INST HAND & MICRO SURG,LOUISVILLE,KY 40202
来源
关键词
D O I
10.1016/0266-7681(94)90129-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Reported complications of endoscopic carpal tunnel release have increased as more surgeons use this technique to release the flexor retinaculum. We used a cadaver model to compare the results of endoscopic carpal tunnel release through a one-portal distal (Group A, 15 specimens) and a one-portal proximal (Group B, 15 specimens) entry site with a new endoscopic technique. Our custom-made glass tube of three different sizes (5, 7, and 9 mm in diameter) is designed to house an endoscope and accommodate a meniscus knife for releasing the flexor retinaculum. Complete release of the flexor retinaculum was obtained in all limbs in both groups. In Group A the one complication (7%) was loss of the cotton tip from the cotton swab stick within the carpal tunnel. In Group B, there was a single case of injury to the superficial palmar arch in one hand and breakage of a glass tube in another hand, for a total complication rate of 13%. No other damage to anatomical structures was noted.
引用
收藏
页码:618 / 621
页数:4
相关论文
共 50 条
  • [31] EARLY RESULTS OF CONVENTIONAL VERSUS 2-PORTAL ENDOSCOPIC CARPAL-TUNNEL RELEASE - A PROSPECTIVE-STUDY
    DUMONTIER, C
    SOKOLOW, C
    LECLERCQ, C
    CHAUVIN, P
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1995, 20B (05): : 658 - 662
  • [32] ULNAR NERVE TRANSECTION AS A COMPLICATION OF 2-PORTAL ENDOSCOPIC CARPAL-TUNNEL RELEASE - REPLY
    MACKINNON, SE
    WEEKS, PM
    NATH, R
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (03): : 522 - 522
  • [33] DISTAL FOREARM REGIONAL BLOCK ANESTHESIA FOR CARPAL-TUNNEL RELEASE
    WILSON, KM
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (03): : 438 - 440
  • [34] LIMITED PORTAL WITH DIRECT-VISION CARPAL-TUNNEL RELEASE
    LOVERME, PJ
    SACCONE, PG
    [J]. ANNALS OF PLASTIC SURGERY, 1995, 34 (03) : 304 - 308
  • [35] Single-portal endoscopic carpal tunnel release: Agee carpal tunnel release system
    Elmaraghy, MW
    Hurst, LN
    [J]. ANNALS OF PLASTIC SURGERY, 1996, 36 (03) : 286 - 291
  • [36] SIGNIFICANCE OF INCOMPLETE RELEASE OF THE DISTAL PORTION OF THE FLEXOR RETINACULUM - IMPLICATIONS FOR ENDOSCOPIC CARPAL-TUNNEL SURGERY
    COBB, TK
    COONEY, WP
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1994, 19B (03): : 283 - 285
  • [37] A preliminary study of single portal endoscopic technique for carpal tunnel release
    Boisrenoult, P
    Desmoineaux, P
    Beaufils, P
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1998, 84 (02): : 136 - 141
  • [38] ENDOSCOPIC CARPAL-TUNNEL RELEASE - A PROSPECTIVE-STUDY OF COMPLICATIONS AND SURGICAL EXPERIENCE
    AGEE, JM
    PEIMER, CA
    PYREK, JD
    WALSH, WE
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (02): : 165 - 171
  • [39] ENDOSCOPIC CARPAL-TUNNEL RELEASE IN A COMMUNITY-BASED SERIES
    FEINSTEIN, PA
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (03): : 451 - 454
  • [40] THE RESULTS OF CARPAL-TUNNEL RELEASE - OPEN VERSUS ENDOSCOPIC TECHNIQUE
    BANDE, S
    DESMET, L
    FABRY, G
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1994, 19B (01): : 14 - 17