LARGE CERVICAL OSTEOPHYTE - ANOTHER CAUSE OF DIFFICULT FLEXIBLE FIBEROPTIC INTUBATION

被引:12
|
作者
RANASINGHE, DN [1 ]
CALDER, I [1 ]
机构
[1] ROYAL FREE HOSP,DEPT ANAESTHESIA,LONDON NW3 2QG,ENGLAND
关键词
INTUBATION; TRACHEAL; FIBEROPTIC; DIFFICULT; COMPLICATIONS; ANKYLOSING SPONDYLITIS;
D O I
10.1111/j.1365-2044.1994.tb03524.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A patient suffering from ankylosing spondylitis required surgical excision of a large anterior osteophyte of the cervical spine. Fibreoptic nasal intubation was difficult due to distortion of the airway by the osteophyte. This cause of difficult flexible fibreoptic intubation has not been described previously. Copyright © 1994, Wiley Blackwell. All rights reserved
引用
收藏
页码:512 / 514
页数:3
相关论文
共 50 条
  • [41] Use of a fiberoptic cystoscope to facilitate intubation in a difficult airway
    Roark, GL
    [J]. TROPICAL DOCTOR, 2006, 36 (02) : 104 - 105
  • [42] A Simple Approach to Facilitating Fiberoptic Intubation in the Difficult Airway
    Heir, Jagtar Singh
    Kupferman, Michael E.
    [J]. LARYNGOSCOPE, 2011, 121 (02): : 310 - 312
  • [43] Giant Cervical Osteophyte: An Unusual Cause of Dysphagia
    Srivastava, Sudhir Kumar
    Bhosale, Sunil Krishna
    Lohiya, Tanvi Anoop
    Aggarwal, Rishi Anil
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (10) : MD1 - MD2
  • [44] Tracheal intubation with the Bonfils fiberscope in the difficult pediatric airway: a comparison with fiberoptic intubation
    Kaufmann, Jost
    Laschat, Michael
    Engelhardt, Thomas
    Hellmich, Martin
    Wappler, Frank
    [J]. PEDIATRIC ANESTHESIA, 2015, 25 (04) : 372 - 378
  • [45] FLEXIBLE FIBEROPTIC BRONCHOSCOPE FOR ENDOTRACHEAL INTUBATION OF INFANTS
    STILES, CM
    [J]. ANESTHESIA AND ANALGESIA, 1974, 53 (06): : 1017 - 1019
  • [46] FIBEROPTIC INTUBATION AND CERVICAL-SPINE PROBLEMS
    BALL, D
    [J]. ANAESTHESIA, 1994, 49 (08) : 737 - 738
  • [47] FLEXIBLE TRACHEAL TUBES FACILITATE FIBEROPTIC INTUBATION
    KLAFTA, JM
    [J]. ANESTHESIA AND ANALGESIA, 1994, 79 (06): : 1211 - 1211
  • [48] ENDOTRACHEAL INTUBATION OF PIGS WITH A FLEXIBLE FIBEROPTIC BRONCHOSCOPE
    MARGOLIN, L
    SHURE, D
    JACOBS, K
    TAYLOR, F
    [J]. LABORATORY ANIMAL SCIENCE, 1987, 37 (04): : 518 - 518
  • [49] SUBGLOTTIC STENOSIS - A CAUSE OF DIFFICULT INTUBATION
    COLGAN, FJ
    KEATS, AS
    [J]. ANESTHESIOLOGY, 1957, 18 (02) : 265 - 269
  • [50] A RARE CAUSE OF UNEXPECTED DIFFICULT INTUBATION
    CHOPRA, V
    [J]. ANAESTHESIA, 1986, 41 (11) : 1158 - 1158