MEASUREMENT OF HYBRIDOMA CELL NUMBER, VIABILITY, AND MORPHOLOGY USING FULLY AUTOMATED IMAGE-ANALYSIS

被引:27
|
作者
TUCKER, KG [1 ]
CHALDER, S [1 ]
ALRUBEAI, M [1 ]
THOMAS, CR [1 ]
机构
[1] UNIV BIRMINGHAM,SERC,CTR BIOCHEM ENGN,SCH CHEM ENGN,BIRMINGHAM B15 2TT,ENGLAND
关键词
HYBRIDOMA; IMAGE ANALYSIS; CELL VIABILITY; CELL MORPHOLOGY;
D O I
10.1016/0141-0229(94)90106-6
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A novel automated image analysis method is described for characterizing the viability and morphology of animal cells from suspension cultures. With the aid of the exclusion dye Trypan Blue, the total and viable cell counts and the percentage of dead cells present are found. The area, perimeter, equivalent diameter, and circularity of the projected image of each cell are also measured, allowing the estimation of cell volume. The image analysis method is inherently sensitive, precise, consistent (non-operator dependent) and relatively fast, taking approximately 22 min. to analyze one sample. The data it gives on individual cellular activity, as characterized by Trypan Blue uptake and cell morphology, are valuable in allowing early diagnosis of even subtle changes in the health of a culture. The method should permit better optimization of culture conditions, and will provide data for the modeling of cell population dynamics. As the conventional manual method is operator dependent, relatively limited in the amount of information it provides, and has a tendency to underestimate Trypan Blue takeup, it is suggested that image analysis be the preferred option for animal cell counting and viability determinations.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [1] AUTOMATED MEASUREMENT OF SPERM MORPHOLOGY BY IMAGE-ANALYSIS
    JAGOE, R
    ALTMAN, D
    WASHBROOK, N
    HUDSON, E
    [J]. JOURNAL OF PATHOLOGY, 1985, 145 (01): : A103 - A103
  • [2] AUTOMATED MONITORING OF CELL CONCENTRATION AND VIABILITY USING AN IMAGE-ANALYSIS SYSTEM
    MARUHASHI, F
    MURAKAMI, S
    BABA, K
    [J]. CYTOTECHNOLOGY, 1994, 15 (1-3) : 281 - 289
  • [3] FULLY-AUTOMATIC MEASUREMENT OF MYCELIAL MORPHOLOGY BY IMAGE-ANALYSIS
    TUCKER, KG
    KELLY, T
    DELGRAZIA, P
    THOMAS, CR
    [J]. BIOTECHNOLOGY PROGRESS, 1992, 8 (04) : 353 - 359
  • [4] FULLY AUTOMATED SEM IMAGE-ANALYSIS
    EDWARDS, RM
    LEBIEDZIK, J
    STONE, G
    [J]. SCANNING, 1986, 8 (05) : 221 - 231
  • [5] AUTORADIOGRAPHIC GRAIN COUNTING BY FULLY AUTOMATED IMAGE-ANALYSIS
    KEMPF, J
    KEMPF, C
    [J]. MICROSCOPICA ACTA, 1982, 86 (03): : 215 - 223
  • [6] IMAGE-ANALYSIS USING MATHEMATICAL MORPHOLOGY
    HARALICK, RM
    STERNBERG, SR
    ZHUANG, XH
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (04) : 532 - 550
  • [7] CLASSIFICATION AND MEASUREMENT OF FUNGAL PELLETS BY AUTOMATED IMAGE-ANALYSIS
    COX, PW
    THOMAS, CR
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1992, 39 (09) : 945 - 952
  • [8] LIBERATION MODELING USING AUTOMATED IMAGE-ANALYSIS
    CHOI, WZ
    ADEL, GT
    YOON, RH
    [J]. INTERNATIONAL JOURNAL OF MINERAL PROCESSING, 1988, 22 (1-4) : 59 - 73
  • [9] A STRATEGY FOR THE EFFICIENT DEVELOPMENT AND OPTIMIZATION OF FULLY AUTOMATED IMAGE-ANALYSIS PROCEDURES
    GRAHAM, S
    ABEL, P
    HAMMOND, S
    LEWORTHY, D
    PARTINGTON, D
    [J]. ACTA STEREOLOGICA, VOL 8, NOS 1 AND 2: PROCEEDINGS OF THE FIFTH EUROPEAN CONGRESS FOR STEREOLOGY, 1989, : 527 - 532
  • [10] FULLY AUTOMATED IMAGE-ANALYSIS OF ETCHED TRACKS IN CR-39
    FEWS, AP
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 71 (04): : 465 - 478