MR PERFUSION STUDIES WITH T-1-WEIGHTED ECHO-PLANAR IMAGING

被引:378
|
作者
KWONG, KK
CHESLER, DA
WEISSKOFF, RM
DONAHUE, KM
DAVIS, TL
OSTERGAARD, L
CAMPBELL, TA
ROSEN, BR
机构
[1] HARVARD UNIV,SCH MED,BOSTON,MA
[2] HARVARD MIT DIV HLTH & TECHNOL,BOSTON,MA
关键词
T-1; PERFUSION; TUMOR; FMRI; EPI;
D O I
10.1002/mrm.1910340613
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The T-1 perfusion model has worked well in brain functional studies where flow changes are measured, Using selective and nonselective inversion pulses, a new method has been developed to study steady-state brain blood flow, The authors obtained flow-sensitive images using selective inversion and flow-insensitive images using nonselective inversion, Subtraction of flow-insensitive images from few-sensitive images gave us flow-weighted images with good gray-white flow contrast in cortical gray matter as well as in the thalamus and basal ganglia. Fitting T(1)s of flow-insensitive and flow-sensitive images allowed us to obtain preliminary results of brain blood flow maps, Two specific problems can seriously affect the accuracy of the brain blood flow values and the gray-white flow contrast of brain blood flow maps, These are the problems of the partial volume effect of CSF and gray matter, and the difference between blood T-1, and white matter T-1. The authors discuss in detail the character of these problems and present a number of approaches to manage such problems.
引用
收藏
页码:878 / 887
页数:10
相关论文
共 50 条
  • [21] CLINICAL UTILITY OF PERFUSION-WEIGHTED ECHO-PLANAR IR SE FUNCTIONAL MR-IMAGING IN THE EVALUATION OF INTRACRANIAL NEOPLASMS
    LEV, MH
    KWONG, K
    RABINOV, JD
    SORENSEN, AG
    OSTERGARD, L
    ROSEN, BR
    RADIOLOGY, 1995, 197 : 168 - 168
  • [22] T2-weighted prostate imaging using echo-planar imaging at 3T
    Ragan, D
    Ma, J
    MEDICAL PHYSICS, 2005, 32 (06) : 1911 - 1911
  • [23] ECHO-PLANAR IMAGING
    DELAPAZ, RL
    RADIOGRAPHICS, 1994, 14 (05) : 1045 - 1058
  • [24] Gadolinium-enhanced mr imaging of normal renal transplants -: An evaluation of a T1-weighted dynamic echo-planar sequence
    Dupas, B
    Bach-Gansmo, T
    Blancho, G
    Franconi, JM
    Havet, T
    Léauté, F
    ACTA RADIOLOGICA, 1999, 40 (03) : 250 - 254
  • [25] Echo-Planar Imaging
    University of Nottingham, United Kingdom
    eMagRes, 2007,
  • [26] ECHO-PLANAR PERFUSION-SENSITIVE MR-IMAGING OF ACUTE CEREBRAL-ISCHEMIA
    KUCHARCZYK, J
    VEXLER, ZS
    ROBERTS, TP
    ASGARI, HS
    MINTOROVITCH, J
    DERUGIN, N
    WATSON, AD
    MOSELEY, ME
    RADIOLOGY, 1993, 188 (03) : 711 - 717
  • [27] Diffusion-weighted echo-planar MR imaging: clinical applications and pitfalls - A pictorial essay
    Moritani, T
    Shrier, DA
    Numaguchi, Y
    Takase, Y
    Takahashi, C
    Wang, HZ
    Shibata, DK
    Abe, T
    Ukisu, R
    Ohgiya, Y
    Tsuchiya, A
    Kushihashi, T
    Gokan, T
    Munechika, H
    CLINICAL IMAGING, 2000, 24 (04) : 181 - 192
  • [28] Mediastinal Mass: Assessment with Diffusion-weighted Single Shot Echo-planar MR Imaging
    Razek, Abdel A.
    Elshafeay, M.
    Elhadedy, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [29] Head and neck masses: Diagnostic value of diffusion-weighted echo-planar MR imaging
    Wang, J
    Takashima, S
    Takayama, F
    Wang, Q
    Kawakami, S
    Saito, A
    RADIOLOGY, 2000, 217 : 473 - 473
  • [30] Diffusion-weighted echo-planar MR imaging of CNS involvement in systemic lupus erythematosus
    Moritani, T
    Shrier, DA
    Numaguchi, Y
    Takahashi, C
    Yang, T
    ACADEMIC RADIOLOGY, 2001, 8 (08) : 741 - 753