DECENTRATION OF THE POSTERIOR CHAMBER LENS IMPLANT - A COMPARISON OF CAPSULORHEXIS WITH ENDOCAPSULAR SURGERY

被引:4
|
作者
POLLOCK, WST [1 ]
CASSWELL, AG [1 ]
机构
[1] SUSSEX EYE HOSP,BRIGHTON BN2 5BF,E SUSSEX,ENGLAND
关键词
D O I
10.1038/eye.1994.168
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The optical effect of posterior chamber lens decentration is a well-recognised complication of cataract surgery causing significant symptoms even with the larger-diameter implant optics available. In this paper we present the results of a study of implant decentration occurring with extracapsular surgery, in which we compared a group of patients with one tear in the anterior capsule with a second group with two tears in the anterior capsule. Our findings show that lens decentration is greater in those patients with two tears of the anterior capsule, and this difference is statistically significant.
引用
收藏
页码:680 / 683
页数:4
相关论文
共 50 条
  • [1] DECENTRATION OF THE POSTERIOR CHAMBER LENS IMPLANT - THE EFFECT OF OPTIC SIZE ON THE INCIDENCE OF VISUAL ABERRATIONS
    MCDONNELL, PJ
    SPALTON, DJ
    FALCON, MG
    [J]. EYE, 1990, 4 : 132 - 137
  • [2] Explantation of endocapsular posterior chamber lens after spontaneous posterior dislocation
    Nishi, O
    Nishi, K
    Sakanishi, K
    Yamada, Y
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (02): : 272 - 275
  • [3] Intraocular lens tilt and decentration after cataract surgery with and without primary posterior continuous curvilinear capsulorhexis
    Liu, Xiaobao
    Yu, Mengting
    Huang, Yue
    Li, Qiong
    Wu, Wenjie
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (05): : 492 - 498
  • [4] TILT AND DECENTRATION OF THE IMPLANTED POSTERIOR CHAMBER INTRAOCULAR-LENS
    KOZAKI, J
    TANIHARA, H
    YASUDA, A
    NAGATA, M
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (05): : 592 - 595
  • [5] CAPSULORHEXIS, PHACOEMULSIFICATION, AND POSTERIOR CHAMBER LENS PLACEMENT FOLLOWING IRIDOCYCLECTOMY
    LINDQUIST, TD
    [J]. OPHTHALMIC SURGERY AND LASERS, 1992, 23 (01): : 44 - 46
  • [6] INTRACAPSULAR CATARACT-SURGERY WITH THE SEVERIN (POSTERIOR CHAMBER) LENS IMPLANT
    ROSEN, ES
    [J]. OPHTHALMOLOGICA, 1983, 187 (02) : 94 - 107
  • [7] INVIVO MEASUREMENT OF POSTERIOR CHAMBER INTRAOCULAR-LENS DECENTRATION AND TILT
    AURAN, JD
    KOESTER, CJ
    DONN, A
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (01) : 75 - 79
  • [8] Intraocular lens tilt and decentration after Nd:YAG laser posterior capsulotomy: Femtosecond laser capsulorhexis versus manual capsulorhexis
    Cinar, Esat
    Yuce, Berna
    Aslan, Fatih
    Erbakan, Gokhan
    Kucukerdonmez, Cem
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11): : 1637 - 1644
  • [9] POSTERIOR CAPSULAR OPACIFICATION AND INTRAOCULAR-LENS DECENTRATION .1. COMPARISON OF VARIOUS POSTERIOR CHAMBER LENS DESIGNS IMPLANTED IN THE RABBIT MODEL
    HANSEN, SO
    SOLOMON, KD
    MCKNIGHT, GT
    WILBRANDT, TH
    GWIN, TD
    OMORCHOE, DJC
    TETZ, MR
    APPLE, DJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (06): : 605 - 613
  • [10] A CLINICOPATHOLOGICAL REPORT OF A POSTERIOR CHAMBER LENS IMPLANT
    CRAWFORD, BA
    WEINER, JM
    [J]. AUSTRALIAN JOURNAL OF OPHTHALMOLOGY, 1983, 11 (04): : 303 - 308