Core balance ground fault protection of motors on a low-resistance grounded, medium-voltage system

被引:4
|
作者
Breitkreutz, B [1 ]
Frere, A [1 ]
机构
[1] GE CO,HOUSTON,TX 77036
关键词
D O I
10.1109/28.475732
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The core balance current transformer is the basis for sensitive ground fault protection of motors. All phase conductors pass through the same opening in the current transformer so that it senses only zero sequence or ground current. Possible sources of nonfault relay current include current transformer error, harmonics, and unbalanced currents through impedances to ground, especially capacitances. The core balance connected ground fault relay is usually an instantaneous type, or a time-delay type of the short time or very inverse characteristic. The standards provide typical ranges of relay settings. They do not provide a procedure for determining the minimum settings that will not result in nuisance trips from nonfault currents nor the maximum settings that will provide adequate protection. This paper develops that procedure.
引用
下载
收藏
页码:1398 / 1401
页数:4
相关论文
共 50 条
  • [1] High sensitive ground fault location in a low-resistance grounded system
    Liao F.
    Li H.
    Chen J.
    Liang Y.
    Wang G.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (21): : 150 - 158
  • [2] CONSIDERATIONS FOR GROUND FAULT PROTECTION IN MEDIUM-VOLTAGE INDUSTRIAL AND COGENERATION SYSTEMS
    LOVE, DJ
    HASHEMI, N
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1988, 24 (04) : 548 - 553
  • [3] Effects of imbalance on single-phase to ground fault characteristics in low-resistance grounded systems
    Li, Haifeng
    Chen, Jiaquan
    Liang, Yuansheng
    Liao, Fangqun
    Wang, Gang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 115
  • [4] Centralized protection for a grounding fault in a low-resistance grounding distribution system
    Wu H.
    Chen J.
    Liao F.
    Li Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (21): : 141 - 149
  • [5] Regionalized Zero-sequence Protection for Low-resistance Grounded System with Distributed Generator
    Qiao Y.
    Wu H.
    Wu T.
    Li X.
    Hou X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (10): : 186 - 194
  • [6] A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
    Zhang, Pinjia
    Du, Yi
    Habetler, Thomas G.
    Lu, Bin
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2011, 47 (01) : 34 - 46
  • [7] GROUND FAULT PROTECTION IN LOW VOLTAGE SOLIDLY GROUNDED WYE SYSTEMS, NEED FOR PROTECTION AND THE NEED FOR RELIABILITY
    Valdes, Marcelo
    CONFERENCE RECORD 2008 IEEE INDUSTRIAL & COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE, 2008, : 144 - 152
  • [8] Shipboard Medium-Voltage DC Integrated Power System Ⅱ: Protection and Fault Management Technology
    Yang, Yayu
    Tai, Nengling
    Huang, Wentao
    Yu, Moduo
    Liu, Yu
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (23): : 7341 - 7364
  • [9] Single-phase high-impedance fault protection for low-resistance grounded distribution network
    Tang, Tao
    Huang, Chun
    Hua, Leng
    Zhu, Jiran
    Zhang, Zhidan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (10) : 2462 - 2470
  • [10] A NEW FAULT-INTERRUPTING DEVICE FOR IMPROVED MEDIUM-VOLTAGE SYSTEM AND EQUIPMENT PROTECTION
    GLENN, DJ
    COOK, CJ
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1985, 21 (05) : 1324 - 1332