SANDWICH-TYPE AMPEROMETRIC ENZYME ELECTRODES FOR DETERMINATION OF GLUCOSE

被引:0
|
作者
MUTLU, S
MUTLU, M
VADGAMA, P
PISKIN, E
机构
[1] HACETTEPE UNIV,DEPT FOOD ENGN,ANKARA 06530,TURKEY
[2] UNIV MANCHESTER,CLIN BIOCHEM SECT,DEPT MED,SALFORD M6 8HD,LANCS,ENGLAND
来源
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Sandwich type amperometric enzyme electrodes for glucose based on oxidases were studied. Polyethersulphone (PES) and polycarbonate (PC) membranes were used as inner and outer membranes, respectively. Glucose oxidase was entrapped between these two membranes. The selectivity of the inner membrane against a group of electroactive compounds in blood were tested. The PES membrane fulfilled all the requirements of a permselective membrane. The outer surface of PC membranes were further modified by deposition of hexamethyldisiloxane (HMDS) in a glow-discharge reactor or by coating with polyvinylalcohol (PVAL) to increase the linear range of the electrode while keeping or improving the blood-compatible properties of membrane. Linearity of these enzyme electrodes were investigated in different media (i.e., buffer solutions, blood plasma and blood). Blood-compatibilities of the PC membrane and its modified forms were obtained in in-vitro experiments. HMDS treatment significantly increased the linearity of enzyme electrode but did not affect their blood-compatibilities or significantly change the selectively. Also, the PVAL coating, considerably, extended the linear range of the electrode, slightly improved blood-compatibility but did not change the selectivity.
引用
收藏
页码:71 / 83
页数:13
相关论文
共 50 条
  • [21] Optimization of a reusable sandwich-type amperometric phenol biosensor. Experimental and theoretical outcomes
    Zoratti, Marianela
    Colombo, Lucas
    Garay, Fernando
    [J]. ELECTROCHIMICA ACTA, 2024, 493
  • [22] SANDWICH-TYPE ENZYME-IMMUNOASSAY FOR HUMAN CHORIONIC-GONADOTROPIN
    SEKIYA, T
    FURUHASHI, Y
    GOTO, S
    KASEKI, S
    TOMODA, Y
    KATO, K
    [J]. JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 1981, 4 (03): : 275 - 279
  • [23] GLUCOSE BIOSENSORS BASED ON OXYGEN-ELECTRODE WITH SANDWICH-TYPE MEMBRANES
    YANG, SP
    ATANASOV, P
    WILKINS, E
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1995, 23 (06) : 833 - 839
  • [24] Analysis and optimization of a hydrogel matrix for the development of a sandwich-type glucose biosensor
    Colombo, Lucas
    Maria Baruzzi, Ana
    Sebastian Garay, Fernando
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 211 : 125 - 130
  • [25] Irregularly shaped gold nanoparticles as secondary labels for enhanced electrochemical sandwich-type enzyme immunoassay for the determination of biomarkers
    Sun, Ai Li
    Qi, Qing An
    Dong, Zhuang Long
    [J]. CHEMISTRY LETTERS, 2008, 37 (06) : 600 - 601
  • [26] THE BUCKLING OF SANDWICH-TYPE PANELS
    HOFF, NJ
    MAUTNER, SE
    [J]. JOURNAL OF THE AERONAUTICAL SCIENCES, 1945, 12 (03): : 285 - 297
  • [27] Amperometric sandwich-type aptasensor based on peroxidase mimetic Au@Pt for the carcinoembryonic antigen
    Li, Hui
    Zhang, Yuting
    Chang, Anqi
    Cai, Shixin
    Zhou, Nandi
    [J]. ELECTROANALYSIS, 2023, 35 (05)
  • [28] AMPEROMETRIC AND POTENTIOMETRIC ENZYME ELECTRODES
    HO, MH
    WU, TG
    [J]. ISA TRANSACTIONS, 1985, 24 (01) : 61 - 67
  • [29] Benzoquinone-mediated enzyme biosensor for amperometric determination of glucose
    A S N Murthy
    Jyotsna Sharma
    [J]. Proceedings of the Indian Academy of Sciences - Chemical Sciences, 1997, 109 (4): : 295 - 301
  • [30] Benzoquinone-mediated enzyme biosensor for amperometric determination of glucose
    Murthy, ASN
    Sharma, J
    [J]. PROCEEDINGS OF THE INDIAN ACADEMY OF SCIENCES-CHEMICAL SCIENCES, 1997, 109 (04): : 295 - 301