SANDWICH-TYPE AMPEROMETRIC ENZYME ELECTRODES FOR DETERMINATION OF GLUCOSE

被引:0
|
作者
MUTLU, S
MUTLU, M
VADGAMA, P
PISKIN, E
机构
[1] HACETTEPE UNIV,DEPT FOOD ENGN,ANKARA 06530,TURKEY
[2] UNIV MANCHESTER,CLIN BIOCHEM SECT,DEPT MED,SALFORD M6 8HD,LANCS,ENGLAND
来源
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Sandwich type amperometric enzyme electrodes for glucose based on oxidases were studied. Polyethersulphone (PES) and polycarbonate (PC) membranes were used as inner and outer membranes, respectively. Glucose oxidase was entrapped between these two membranes. The selectivity of the inner membrane against a group of electroactive compounds in blood were tested. The PES membrane fulfilled all the requirements of a permselective membrane. The outer surface of PC membranes were further modified by deposition of hexamethyldisiloxane (HMDS) in a glow-discharge reactor or by coating with polyvinylalcohol (PVAL) to increase the linear range of the electrode while keeping or improving the blood-compatible properties of membrane. Linearity of these enzyme electrodes were investigated in different media (i.e., buffer solutions, blood plasma and blood). Blood-compatibilities of the PC membrane and its modified forms were obtained in in-vitro experiments. HMDS treatment significantly increased the linearity of enzyme electrode but did not affect their blood-compatibilities or significantly change the selectively. Also, the PVAL coating, considerably, extended the linear range of the electrode, slightly improved blood-compatibility but did not change the selectivity.
引用
收藏
页码:71 / 83
页数:13
相关论文
共 50 条
  • [1] MONOALKYLFERROCENE-MEDIATED AMPEROMETRIC ENZYME ELECTRODES FOR GLUCOSE DETERMINATION
    RAZUMAS, V
    KULYS, J
    KNICHEL, M
    WIEMHOFER, HD
    GOPEL, W
    [J]. ELECTROANALYSIS, 1993, 5 (5-6) : 399 - 404
  • [2] POLYMER-COMPLEX MEDIATED ENZYME ELECTRODES FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    OYAMA, N
    OHSAKA, T
    IKEDA, S
    [J]. JOURNAL OF MACROMOLECULAR SCIENCE-CHEMISTRY, 1990, A27 (9-11): : 1203 - 1216
  • [3] Enzyme electrodes for rapid amperometric blood glucose level determination.
    Sistare, MF
    Palmer, P
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U79 - U79
  • [4] Amperometric detection of an oligonucleotide at 20 pM concentration by an enzyme-amplified sandwich-type assay.
    Zhang, YC
    Kim, HH
    Heller, A
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U125 - U126
  • [5] Mathematical modeling and experimental results of a sandwich-type amperometric biosensor
    Ricardo Romero, Marcelo
    Baruzzi, Ana M.
    Garay, Fernando
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 162 (01) : 284 - 291
  • [6] WIRED ENZYME ELECTRODES FOR AMPEROMETRIC DETERMINATION OF GLUCOSE OR LACTATE IN THE PRESENCE OF INTERFERING SUBSTANCES
    OHARA, TJ
    RAJAGOPALAN, R
    HELLER, A
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (15) : 2451 - 2457
  • [7] AMPEROMETRIC ENZYME-MODIFIED ELECTRODES BASED ON TETRATHIAFULVALENE DERIVATIVES FOR THE DETERMINATION OF GLUCOSE
    LEE, HS
    LIU, LF
    HALE, PD
    OKAMOTO, Y
    [J]. HETEROATOM CHEMISTRY, 1992, 3 (03) : 303 - 310
  • [8] ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    GUILBAULT, GG
    LUBRANO, GJ
    [J]. ANALYTICA CHIMICA ACTA, 1973, 64 (03) : 439 - 455
  • [9] ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    GUILBAUL.GG
    LUBRANO, GJ
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1973, : 12 - +
  • [10] Amperometric aptasensor with sandwich-type architecture for troponin I based on carboxyethylsilanetriol-modified graphene oxide coated electrodes
    Villalonga, Anabel
    Estabiel, Itziar
    Perez-Calabuig, Ana M.
    Mayol, Beatriz
    Parrado, Concepcion
    Villalonga, Reynaldo
    [J]. BIOSENSORS & BIOELECTRONICS, 2021, 183