CONTROLLED DRUG DELIVERY DEVICES FOR EXPERIMENTAL OCULAR STUDIES WITH TIMOLOL .1. INVITRO RELEASE STUDIES

被引:27
|
作者
URTTI, A
PIPKIN, JD
RORK, G
REPTA, AJ
机构
[1] INTERX RES CORP,MERCK SHARP & DOHME RES LABS,LAWRENCE,KS 66047
[2] UNIV KANSAS,DEPT PHARMACEUT CHEM,LAWRENCE,KS 66045
关键词
Controlled release; Drug delivery device; Ocular drug delivery; Release rate; Silicone tubing; Timolol;
D O I
10.1016/0378-5173(90)90214-O
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Controlled drug delivery devices which can be easily tailored and conveniently prepared to release ocular drugs at specified controlled rates can be useful in studies of ocular drug delivery and drug response. The devices were fabricated by injecting 6.0, 9.0 or 12.5 μl of aqueous borate buffered solutions of timolol (2.5-20.0 mg ml) into end-plugged pieces of silicone tubing and the release of timolol was studied in vitro. An initial lag in timolol release was avoided by storing the devices for an appropriate time (3-9 h) after filling the devices. The appropriate storage time was dependent on the steady-state flux of timolol, indicating that timolol was binding to the silica filler in the silicone tubing. Timolol was released at a constant rate (0.7-7.2 μg h) for 8 h from the devices when the initial core pH was 8.64 and when the devices were stored for an appropriate time before an experiment. The steady-state release rate of timolol was increased 2.4-fold when the pH inside the device was increased from 8.34 to 9.24, As expected, the observed release rate increased with increased drug concentration in the device core and with increased length of the device. The permeability of timolol in the silicone membrane walls was 2.48-6.03 × 10-9 cm2 s-1 depending on the composition of the inner core solution. Thickness of the end-plugs (0.5 or 3.5 mm) did not affect timolol release from the devices, when the volume of timolol solution in the devices was 12.5 μl. © 1990.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 50 条
  • [21] CONTROLLED RELEASE 5-FU DELIVERY SYSTEMS - RELEASE STUDIES, INVITRO INVIVO CORRELATION AND HPLC ASSAY
    BROWN, JD
    PEARSON, PA
    BLANDFORD, D
    SMITH, TJ
    ASHTON, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1293 - 1293
  • [22] Recent studies and molecular analysis of drug release from swelling-controlled devices
    Brazel, CS
    Peppas, NA
    STP PHARMA SCIENCES, 1999, 9 (05): : 473 - 485
  • [23] STUDIES ON INVITRO DRUG RELEASE FROM AQUEOUS GELS
    TANAKA, S
    MATSUYAMA, M
    AIKAWA, Y
    KAWAMATA, I
    KOUCHIWA, S
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1987, 76 (11) : S303 - S303
  • [24] METHYLPREDNISOLONE ESTERS OF HYALURONIC-ACID IN OPHTHALMIC DRUG DELIVERY - INVITRO AND INVIVO RELEASE STUDIES
    KYYRONEN, K
    HUME, L
    BENEDETTI, L
    URTTI, A
    TOPP, E
    STELLA, V
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1992, 80 (2-3) : 161 - 169
  • [25] Design of diffusion-controlled drug delivery devices for controlled release of Paclitaxel
    Pramanik, Anurag
    Garg, Sanjeev
    CHEMICAL BIOLOGY & DRUG DESIGN, 2019, 94 (02) : 1478 - 1487
  • [26] STUDIES ON EXPERIMENTAL OCULAR TOXOPLASMOSIS IN RABBIT .1. EFFECT OF ANTIGENIC STIMULATION
    NOZIK, RA
    OCONNOR, GR
    ARCHIVES OF OPHTHALMOLOGY, 1970, 83 (06) : 724 - &
  • [27] STUDIES OF STABILITY OF AMPHETAMINIL .1. INVITRO STUDIES - REPLY
    HONECKER, H
    COPER, H
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1975, 25 (05): : 837 - 837
  • [28] DESIGN AND INVITRO EVALUATION OF A CONTROLLED RELEASE DRUG DELIVERY SYSTEM OF SULFASOMIDINE
    DAS, SK
    GUPTA, BK
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1985, 11 (08) : 1621 - 1638
  • [29] Experimental Studies and Modeling of Drug Release from a Tunable Affinity-Based Drug Delivery Platform
    Andrew S. Fu
    Thimma R. Thatiparti
    Gerald M. Saidel
    Horst A. von Recum
    Annals of Biomedical Engineering, 2011, 39 : 2466 - 2475
  • [30] Experimental Studies and Modeling of Drug Release from a Tunable Affinity-Based Drug Delivery Platform
    Fu, Andrew S.
    Thatiparti, Thimma R.
    Saidel, Gerald M.
    von Recum, Horst A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (09) : 2466 - 2475