OPTIMAL-CONTROL FOR THE ACTIVE ABOVE-KNEE PROSTHESIS

被引:31
|
作者
POPOVIC, D
OGUZTORELI, MN
STEIN, RB
机构
[1] UNIV ALBERTA,DIV NEUROSCI,EDMONTON T6G 2S2,ALBERTA,CANADA
[2] UNIV ALBERTA,DEPT MATH,EDMONTON T6G 2E1,ALBERTA,CANADA
[3] UNIV BELGRADE,FAC ELECT ENGN,BELGRADE,YUGOSLAVIA
关键词
OPTIMAL TRACKING; DYNAMIC PROGRAMMING; ABOVE-KNEE PROSTHESIS;
D O I
10.1007/BF02368465
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Control of an active above-knee prosthesis has been simulated for a selected gait activity using a hierachical closed-loop method. An extension of finite-state control, referred to as artificial reflex control, was adopted at the strategic level of control. At the actuator level of control an optimal tracking method, based on dynamic programming, is applied. This deals mainly with the actuator level of control, but considers the interaction of the leg dynamics and the switching effects of artificial reflex control. Optimal tracking at the actuator level of the above-knee prosthesis reduces the on-off effects of finite-state methods, such as artificial reflex control. The proposed method can also be used for the design of prosthetic elements. Specific attention is paid to the limited torque and power in the prosthetic joint actuator, which are imposed by the principle of self-containment in the artificial leg. The hierarchical structure, integrating artificial reflex control and optimal tracking, can be used in real time, as estimated from the number of computer operations required for the suggested method.
引用
收藏
页码:131 / 150
页数:20
相关论文
共 50 条
  • [41] THE EFFECT OF THE CAT CAM ABOVE-KNEE PROSTHESIS ON FUNCTIONAL REHABILITATION
    FLANDRY, F
    BESKIN, J
    CHAMBERS, RB
    PERRY, J
    WATERS, RL
    CHAVEZ, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (239) : 249 - 262
  • [42] Identification of pressure distribution at the socket interface of an above-knee prosthesis
    Osaka Univ, Osaka, Japan
    Adv Eng Software, 6 (379-384):
  • [43] END RESULTS IN SUCTION SOCKET PROSTHESIS FOR ABOVE-KNEE AMPUTEES
    THORNDIKE, A
    AMERICAN JOURNAL OF SURGERY, 1955, 89 (04): : 919 - 923
  • [44] An above-knee prosthesis with a system of energy recovery: A technical note
    Farber, BS
    Jacobson, JS
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1995, 32 (04): : 337 - 348
  • [45] Identification of pressure distribution at the socket interface of an above-knee prosthesis
    Tanaka, M
    Akazawa, Y
    Nakagawa, A
    Kitayama, I
    ADVANCES IN ENGINEERING SOFTWARE, 1997, 28 (06) : 379 - 384
  • [46] BIOFEEDBACK TRAINING OF KNEE CONTROL IN ABOVE-KNEE AMPUTEE
    FERNIE, G
    HOLDEN, J
    SOTO, M
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1978, 57 (04) : 161 - 166
  • [47] FUZZY CONTROL OF ELECTROHYDRAULIC ABOVE-KNEE PROSTHESES
    JU, MS
    YI, SH
    TSUEI, YG
    CHOU, YL
    JSME INTERNATIONAL JOURNAL SERIES C-DYNAMICS CONTROL ROBOTICS DESIGN AND MANUFACTURING, 1995, 38 (01): : 78 - 86
  • [48] Application of Wireless, Embedded Microcontroller Circuit for a Semi-Active Above-Knee Prosthesis with Pneumatic Cylinder
    Saracoglu, Mevlut Said
    Sahin, Dogukan
    Orhanli, Tuna
    Yilmaz, Atila
    2015 23RD SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2015, : 2258 - 2261
  • [49] Application and Comparison of Finite State Control of Above-Knee Prosthesis with Pneumatic Cylinder at Different Phases
    Orhanli, Tuna
    Yilmaz, Atila
    2015 23RD SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2015, : 2234 - 2237
  • [50] DESIGN, CONSTRUCTION, AND TESTING OF AN ELECTROMYOGRAM-CONTROLLED ABOVE-KNEE PROSTHESIS
    LERNER, S
    LACARRUBBA, J
    FINKELSTEIN, SM
    MASON, C
    BIOTELEMETRY, 1975, 2 (1-2) : 37 - 38