RIGHT-VENTRICULAR ASSIST DEVICE (RVAD) FOR FULMINANT SEPTIC PULMONARY-ARTERY EMBOLISM

被引:0
|
作者
KALTENBOCK, F
GOMBOTZ, H
TSCHELIESSNIGG, KH
MATZER, C
WINKLER, G
AUER, T
机构
[1] GRAZ UNIV,CHIRURG KLIN,A-8036 GRAZ,AUSTRIA
[2] LKH WAGNA,INST ANASTHESIOL,WAGNA,AUSTRIA
来源
ANAESTHESIST | 1993年 / 42卷 / 11期
关键词
PULMONARY EMBOLISM; SEPSIS; RIGHT HEART FAILURE; RIGHT VENTRICULAR ASSIST DEVICE;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We describe a 34-year-old male with pulmonary embolism. The patient had been admitted to a peripheral hospital for incision and drainage of a very large ischio-rectal abscess. Four days after successful surgical intervention and during a change of dressings he developed a massive pulmonary artery embolism. The patient was transferred to the Department of Cardiac Surgery in Graz; on arrival he had a cardiac arrest. Resuscitation was initiated and the patient was transferred to the operating theatre where emergency sternotomy and embolectomy revealed large thrombotic masses in the pulmonary circulation. Extracorporeal circulation was initiated, but despite aggressive medical measures (dopamine, dobutamine, isoproterenol, enoximone, and prostaglandin E1 in maximum therapeutic doses) and a long reperfusion time weaning was not possible. Despite the septic state, a right ventricular assist device (RVAD; ABIOMED BVS 5000) was installed. Weaning was finally accomplished with a pump flow of 2.21/min m2 and the patient transferred to the intensive care unit. On postoperative day 3 the pump flow was reduced to 21/min. The patient's condition remained stable, which made removal of the RVAD possible on postoperative day 5. The further course was uneventful, with secondary ischio-rectal wound closure. His initial psychomotor impairment had nearly disappeared and he was discharged 2 months later.
引用
收藏
页码:807 / 810
页数:4
相关论文
共 50 条
  • [21] RIGHT VENTRICULAR SUPPORT BY PULMONARY-ARTERY COUNTERPULSATION
    DREYFUS, G
    GUILLEMAIN, R
    JEBARA, VA
    BERTHIER, B
    LOPART, E
    GUIBOURT, P
    ABRY, B
    CARPENTIER, A
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1989, 82 (01): : 81 - 86
  • [22] Pulmonary Artery Band as Bridge to Ventricular Assist Device by Preconditioning of the Right Ventricle
    Goldberg, Jason F.
    Adachi, Iki
    ANNALS OF THORACIC SURGERY, 2016, 101 (03): : 1244 - 1245
  • [23] LOAD-INDEPENDENT ANALYSIS OF A PULSATILE RIGHT-VENTRICULAR ASSIST DEVICE
    MEYERS, CH
    PETERSEIM, DS
    UPPAL, R
    JAYAWANT, AM
    CAMPBELL, KA
    SABISTON, DC
    SMITH, PK
    VANTRIGT, P
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1995, 14 (01): : 177 - 185
  • [24] Right-ventricular failure following left ventricle assist device implantation
    Patlolla, Bhagat
    Beygui, Ramin
    Haddad, Francois
    CURRENT OPINION IN CARDIOLOGY, 2013, 28 (02) : 223 - 233
  • [25] IMPORTANCE OF ATTACHING THE REFERENCE ELECTRODE WHEN USING A RIGHT-VENTRICULAR EJECTION FRACTION PULMONARY-ARTERY CATHETER
    MCNULTY, SE
    GLOWACKI, SJ
    BENSON, DM
    ANESTHESIOLOGY, 1995, 83 (3A) : A1055 - A1055
  • [26] Banding of Right Ventricular Assist Device (RVAD) of Outflow Conduit: Is It Really Necessary With Current Devices?
    Lo, C.
    Gregory, S.
    Stevens, M.
    Murphy, D.
    Marasco, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S238 - S238
  • [27] Increased Right Ventricular Assist Device (RVAD) Utilization in Patients with HeartMate 3 Left Ventricular Assist Device (LVAD) in the Post-Approval Era
    Marshall, D.
    DeFilippis, E.
    Truby, L.
    Malick, A.
    Butler, C.
    Griffin, J.
    Clerkin, K.
    Fried, J.
    Raikhelkar, J.
    Yuzefpolskaya, M.
    Colombo, P.
    Sayer, G.
    Takeda, K.
    Takayama, H.
    Naka, Y.
    Farr, M.
    Uriel, N.
    Topkara, V. K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S431 - S431
  • [28] DEVICE FOR PREVENTION OF ACUTE VENOUS THROMBOSIS AND EMBOLISM OF THE PULMONARY-ARTERY
    DUMPE, EP
    NOZDRACHEV, YI
    PEREKATOV, VK
    BYKOV, AF
    KHIRURGIYA, 1981, (02): : 97 - 100
  • [29] Pulmonary embolism after implantation of the left ventricular assist device
    Xiong, Xinghui
    Zhou, Ruihao
    Deng, Lijing
    ASIAN JOURNAL OF SURGERY, 2024, 47 (09) : 4226 - 4228
  • [30] ULTRASONIC EVALUATIONS OF RIGHT VENTRICULAR TO PULMONARY-ARTERY CONDUITS
    JONES, M
    EIDBO, EE
    WALTERS, SM
    CLARK, RE
    CIRCULATION, 1985, 72 (04) : 435 - 435