Donor and surgical risk factors for primary graft failure following Descemet's stripping automated endothelial keratoplasty in Asian eyes

被引:24
|
作者
Ang, Marcus [1 ,2 ]
Htoon, Hla M. [1 ,2 ]
Cajucom-Uy, Howard Y. [1 ,2 ]
Tan, Donald [1 ,2 ,3 ]
Mehta, Jodhbir S. [1 ,2 ,3 ,4 ]
机构
[1] Singapore Natl Eye Ctr, 11 Third Hosp Ave, Bukit Merah 168751, Singapore
[2] Singapore Eye Res Inst, Bukit Merah, Singapore
[3] Natl Univ Singapore, Yong Yoo Lin Sch Med, Dept Ophthalmol, Queenstown, Singapore
[4] Duke NUS, Grad Sch Med, Outram, Singapore
来源
CLINICAL OPHTHALMOLOGY | 2011年 / 5卷
关键词
DSAEK; PGF; penetrating keratoplasty;
D O I
10.2147/OPTH.S25973
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Descemet's stripping automated endothelial keratoplasty (DSAEK) has been shown to have superior refractive and visual results compared with penetrating keratoplasty, but higher rates of primary graft failure (PGF). This paper presents donor and surgical risk factors for PGF in DSAEK cases in Asian eyes. Design: Retrospective case-control study. Participants: All consecutive patients who underwent DSAEK at a tertiary referral teaching hospital from March 2006-December 2008. Methods: Donor details analyzed were: age of donor, cause of donor death, death to harvesting time, donor storage time, distribution distance of tissue, preoperative endothelial cell count. Surgical factors analyzed were: donor diameter, donor thickness, and method of donor insertion. These risk factors in cases of PGF were compared with patients with successful DSAEK as the control group. Main outcome measure: PGF. Results: A total of 124 DSAEK procedures were performed. Six DSAEK procedures (five eyes of five patients; one eye with two failures) resulted in PGF (4.8%). Significant risk factors were found for PGF to include graft insertion using a folding technique (odds ratio [OR], 34.03; 95% confidence interval [CI], 3.75-314.32; P = 0.0017) and a small donor diameter (OR, 39.94; 95% CI, 2.18-732.17; P = 0.013). Conclusion: The results of this study suggest that in Asian eyes with shallow anterior chambers, surgical trauma relating to the technique of donor insertion, and the use of a small donor are major risk factors for PGF following DSAEK.
引用
收藏
页码:1503 / 1508
页数:6
相关论文
共 50 条
  • [11] Outcomes of Ahmed glaucoma valve implantation and risk factors for graft failure in eyes with Descemet's stripping endothelial keratoplasty
    Rai, Mayank
    Mohamed, Ashik
    Chaurasia, Sunita
    Senthil, Sirisha
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (08) : 2335 - 2345
  • [12] Descemet Stripping Automated Endothelial Keratoplasty for Repeated Penetrating Keratoplasty Graft Failure
    Hwang, Gyu Deok
    Yun, Hye Yeon
    Ha, Min Ji
    Whang, Woong Joo
    Chang, Dong Jin
    Hwang, Ho Sik
    Na, Kyung Sun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2021, 62 (03): : 394 - 399
  • [13] Detachment of Donor Graft After Descemet Stripping Automated Endothelial Keratoplasty
    Sykakis, Evripidis
    Georgoudis, Panagiotis
    Hamada, Samer
    Lake, Damian
    JAMA OPHTHALMOLOGY, 2015, 133 (02) : e143259
  • [14] Retrephination of Eccentric Donor Graft for Descemet Stripping Automated Endothelial Keratoplasty
    Kymionis, George D.
    Diakonis, Vasilios F.
    Papathanasiou, Miltiadis
    Yoo, Sonia H.
    CORNEA, 2011, 30 (09) : 1058 - 1060
  • [15] Comparison of primary graft survival following penetrating keratoplasty and Descemet's stripping endothelial keratoplasty in eyes with prior trabeculectomy
    Iverson, Shawn M.
    Spierer, Oriel
    Papachristou, George C.
    Feuer, William J.
    Shi, Wei
    Greenfield, David S.
    O'Brien, Terrence P.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (11) : 1477 - 1482
  • [16] Factors Associated With Graft Detachment After Primary Descemet Stripping Automated Endothelial Keratoplasty
    Nahum, Yoav
    Leon, Pia
    Mimouni, Michael
    Busin, Massimo
    CORNEA, 2017, 36 (03) : 265 - 268
  • [17] Outcomes of rebubbling for graft detachment after Descemet's stripping endothelial keratoplasty or Descemet's stripping automated endothelial keratoplasty
    Bhalerao, Sushank A.
    Mohamed, Ashik
    Vaddavalli, Pravin K.
    Murthy, Somasheila, I
    Reddy, Jagadesh C.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (01) : 48 - 53
  • [18] Endothelial cell counts after Descemet's stripping automated endothelial keratoplasty versus penetrating keratoplasty in Asian eyes
    Ang, Marcus
    Mehta, Jodhbir S.
    Anshu, Arundhati
    Wong, Hon Kiat
    Htoon, Hla M.
    Tan, Donald
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 537 - 544
  • [19] Spontaneous attachment of detached donor-corneal graft following Descemet's stripping automated endothelial keratoplasty
    Jastaneiah, Sabah S.
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2011, 25 (03) : 301 - 303
  • [20] Descemet's Stripping Endothelial Keratoplasty: Long-term Graft Survival and Risk Factors for Failure in Eyes with Preexisting Glaucoma
    Anshu, Arundhati
    Price, Marianne O.
    Price, Francis W.
    OPHTHALMOLOGY, 2012, 119 (10) : 1982 - 1987