LONG-TERM INSTABILITY OF LITHIUM-DRIFTED SILICON DETECTOR

被引:3
|
作者
MIYACHI, T
MATSUZAWA, H
OTOGAWA, T
KOBAYASHI, N
ONABE, H
机构
[1] SHIN ETSU HANDOTAI CO LTD,SEH ISOBE R&D CTR,GUNMA 37901,JAPAN
[2] RAYTECH CO LTD,UTSUNOMIYA,TOCHIGI 321,JAPAN
关键词
SURFACE STATES; SI(LI)-TYPE DETECTOR; STABILITY OF RADIATION DETECTOR; PROGRESSIVE AND REGRESSIVE DETECTOR STATES;
D O I
10.1143/JJAP.34.3065
中图分类号
O59 [应用物理学];
学科分类号
摘要
Using 1150 nm infrared light, the change in the detector sensitivity was studied. As a simple measure of the states of the detector sensitivity, the time derivative of the photocurrent is proposed. In terms of the derivative, the change is uniquely classified into two categories. Even after the detector is aged, the derivative does not remain constant with respect to time and voltage. The physical mechanisms which cause the change are discussed based on possible effects due to unstable surface states and the accumulation of an oxide layer.
引用
收藏
页码:3065 / 3070
页数:6
相关论文
共 50 条
  • [31] ANNULAR LITHIUM-DRIFTED GERMANIUM DETECTOR AS A STANDARD-GEOMETRY GAMMA SPECTROMETER
    LEVY, AJ
    RITTER, RC
    ZIOCK, K
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1967, NS14 (01) : 509 - &
  • [32] ANON - LITHIUM-DRIFTED GERMANIUM DETECTORS
    RUGE, I
    [J]. KERNTECHNIK ISOTOPENTECHNIK UND CHEMIE, 1967, 9 (09): : A160 - &
  • [33] ANON - LITHIUM-DRIFTED GERMANIUM DETECTORS
    不详
    [J]. NUCLEONICS, 1967, 25 (04): : 83 - &
  • [34] LITHIUM-DRIFTED GERMANIUM MEASURES GAMMA POLARIZATION
    不详
    [J]. PHYSICS TODAY, 1970, 23 (07) : 57 - &
  • [35] RESPONSE OF LITHIUM-DRIFTED SILICON RADIATION DETECTORS TO HIGH ENERGY CHARGED PARTICLES
    AITKEN, DW
    EMERSON, DW
    ZULLIGER, HR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (01) : 456 - +
  • [36] Development of Large-area Lithium-drifted Silicon Detectors for the GAPS Experiment
    Kozai, M.
    Fuke, H.
    Yamada, M.
    Erjavec, T.
    Hailey, C. J.
    Kato, C.
    Madden, N.
    Munakata, K.
    Perez, K.
    Rogers, F.
    Saffold, N.
    Shimizu, Y.
    Tokuda, K.
    Xiao, M.
    [J]. 2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [37] The preparation of lithium drifted silicon Si(Li) detector
    Rahab, H
    Keffous, A
    Akam, A
    Menari, H
    [J]. ADVANCED PERFORMANCE MATERIALS, 1999, 6 (01): : 53 - 56
  • [38] LITHIUM-DRIFTED GERMANIUM FOR CHARGED PARTICLE SPECTROSCOPY
    GRUHN, CR
    KUO, T
    MAGGIORE, C
    PREEDOM, B
    SAMUELSON, L
    CHANDER, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (03) : 337 - +
  • [39] POLARISATION SENSITIVITY OF A RECTANGULAR LITHIUM DRIFTED SILICON DETECTOR
    LOGAN, BA
    FAIRWEATHER, IL
    GAUTHIER, R
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1970, 88 (02): : 257 - +
  • [40] AN EFFICIENT DEWAR FOR LITHIUM-DRIFTED GERMANIUM DETECTORS
    KRANER, HW
    SOVKA, JA
    BRECKENRIDGE, RW
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1965, 36 (02): : 328 - +