LONG-TERM INSTABILITY OF LITHIUM-DRIFTED SILICON DETECTOR

被引:3
|
作者
MIYACHI, T
MATSUZAWA, H
OTOGAWA, T
KOBAYASHI, N
ONABE, H
机构
[1] SHIN ETSU HANDOTAI CO LTD,SEH ISOBE R&D CTR,GUNMA 37901,JAPAN
[2] RAYTECH CO LTD,UTSUNOMIYA,TOCHIGI 321,JAPAN
关键词
SURFACE STATES; SI(LI)-TYPE DETECTOR; STABILITY OF RADIATION DETECTOR; PROGRESSIVE AND REGRESSIVE DETECTOR STATES;
D O I
10.1143/JJAP.34.3065
中图分类号
O59 [应用物理学];
学科分类号
摘要
Using 1150 nm infrared light, the change in the detector sensitivity was studied. As a simple measure of the states of the detector sensitivity, the time derivative of the photocurrent is proposed. In terms of the derivative, the change is uniquely classified into two categories. Even after the detector is aged, the derivative does not remain constant with respect to time and voltage. The physical mechanisms which cause the change are discussed based on possible effects due to unstable surface states and the accumulation of an oxide layer.
引用
收藏
页码:3065 / 3070
页数:6
相关论文
共 50 条
  • [1] Position-dependent instability of lithium-drifted silicon detector
    Miyachi, T
    Ohkawa, S
    Matsuzawa, H
    Otogawa, T
    Kobayashi, N
    Onabe, H
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1996, 35 (5A): : 2814 - 2815
  • [2] STABILITY OF A LITHIUM-DRIFTED SILICON DETECTOR
    MIYACHI, T
    OHKAWA, S
    MATSUZAWA, H
    OTOGAWA, T
    KOBAYASHI, N
    ONABE, H
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1994, 33 (7A): : 4111 - 4114
  • [3] LITHIUM-DRIFTED SILICON DETECTOR USED AS A PULSE DOSIMETER
    RAJU, MR
    LAMPO, EJ
    CURTIS, SB
    SPERINDE, JM
    RICHMAN, C
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1967, NS14 (01) : 559 - &
  • [4] LITHIUM-DRIFTED POSITION SENSITIVE DETECTOR
    LUDWIG, EJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1965, 36 (08): : 1175 - &
  • [5] Calibration of 55Fe activity with a lithium-drifted silicon detector
    Yunoki, Akira
    Yamada, Takahiro
    Sato, Yasushi
    Kawada, Yasushi
    Hino, Yoshio
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 756 - 759
  • [6] A LITHIUM-DRIFTED SILICON SURFACE-BARRIER DETECTOR FOR NUCLEAR RADIATIONS
    DEARNALEY, G
    LEWIS, JC
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1964, 25 (02): : 237 - 243
  • [7] GAMMA IRRADIATION OF LITHIUM-DRIFTED SILICON
    KOOL, WH
    GOEDBLOE.JJ
    AMMERLAA.CA
    [J]. JOURNAL OF APPLIED PHYSICS, 1971, 42 (05) : 2024 - &
  • [8] SOME APPLICATIONS OF A LITHIUM-DRIFTED SILICON DETECTOR TO ELECTRON PROBE MICROANALYSIS
    GUTMACHER, RG
    MCCOY, DD
    [J]. APPLIED SPECTROSCOPY, 1969, 23 (06) : 676 - +
  • [9] Lithium-drifted silicon for harsh radiation environments
    Grant, J.
    Buttar, C.
    Brozel, M.
    Keffous, A.
    Cheriet, A.
    Bourenane, K.
    Bourenane, A.
    Kezzoula, F.
    Menari, H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 184 - 187
  • [10] SOME CHARACTERISTICS OF LITHIUM-DRIFTED SILICON STRUCTURES
    BAILY, NA
    AKUTAGAWA, WM
    ANDRES, RJ
    MONTANO, HL
    [J]. JOURNAL OF APPLIED PHYSICS, 1967, 38 (10) : 3907 - +