POTENTIAL OF FLOW-CYTOMETRY FOR PUMP AND PROBE FLUORESCENCE MEASUREMENTS OF PHYTOPLANKTON PHOTOSYNTHETIC CHARACTERISTICS

被引:16
|
作者
OLSON, RJ
ZETTLER, ER
机构
关键词
D O I
10.4319/lo.1995.40.4.0816
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
''Pump and probe'' fluorescence assays provide information about the photosynthetic characteristics of phytoplankton in situ, but at present they measure bulk water samples and thus provide only average values for the whole community (including detritus). We used dual beam flow cytometry to investigate the potential for measuring ''pump and probe'' fluorescence of single cells. For Lauderia borealis (a centric diatom similar to 30 mu m in diameter) in different stages of N-limited batch culture, the fluorescence yield enhancement due to the presence of a ''pump'' beam was correlated with DCMU-enhanced bulk fluorescence, as expected. However, at the appropriate excitation power, fluorescence signals from single cells are so small that for most types of phytoplankton in the oceans, population averaging of signals will be necessary.
引用
收藏
页码:816 / 820
页数:5
相关论文
共 50 条
  • [31] ONLINE FLOW-CYTOMETRY - A VERSATILE METHOD FOR KINETIC MEASUREMENTS
    NOOTER, K
    HERWEIJER, H
    JONKER, RR
    VANDENENGH, GJ
    [J]. METHODS IN CELL BIOLOGY, VOL 41: FLOW CYTOMETRY, 2ND EDITION, PT A, 1994, 41 : 509 - 525
  • [32] POLARIZATION OF FLUORESCENCE - A POSSIBLE METHOD FOR DETECTING CHROMOSOMES IN FLOW-CYTOMETRY
    VENUAT, AM
    MISHAL, Z
    JULIEN, C
    ROSENFELD, C
    [J]. BIOLOGY OF THE CELL, 1985, 55 (1-2) : A28 - A28
  • [33] ENUMERATION OF RETICULOCYTES USING FLUORESCENCE-ACTIVATED FLOW-CYTOMETRY
    CORASH, L
    RHEINSCHMIDT, M
    LIEU, S
    MEERS, P
    BREW, E
    [J]. PATHOLOGY AND IMMUNOPATHOLOGY RESEARCH, 1988, 7 (05): : 381 - 394
  • [34] AN OPTICAL-MODEL FOR FLUORESCENCE OF MAMMALIAN SPERM IN FLOW-CYTOMETRY
    KERKER, M
    WANG, DS
    CHEW, HW
    [J]. CYTOMETRY, 1980, 1 (02): : 161 - 167
  • [35] EVALUATION OF PLATELET GLYCOPROTEIN-IB BY FLUORESCENCE FLOW-CYTOMETRY
    ADELMAN, B
    MICHELSON, AD
    HANDIN, RI
    AULT, KA
    [J]. BLOOD, 1985, 66 (02) : 423 - 427
  • [36] A FLUORESCENCE CYTO-TOXICITY ASSAY USING FLOW-CYTOMETRY
    NOCERA, A
    CANTARELLA, S
    SANTORO, F
    BAROCCI, S
    CELADA, F
    [J]. BASIC AND APPLIED HISTOCHEMISTRY, 1988, 32 (03): : 379 - 379
  • [37] DECREASED AUTOLOGOUS FLUORESCENCE IN FLOW-CYTOMETRY OF CULTURED-CELLS
    KAWAHARA, H
    YAMADA, K
    AKIYAMA, K
    TACHIBANA, H
    SHIRAHATA, S
    MURAKAMI, H
    [J]. NIPPON NOGEIKAGAKU KAISHI-JOURNAL OF THE JAPAN SOCIETY FOR BIOSCIENCE BIOTECHNOLOGY AND AGROCHEMISTRY, 1991, 65 (05): : 879 - 881
  • [38] QUANTITATIVE SPECIATION OF BACTERIAL MIXTURES USING FLUORESCENCE FLOW-CYTOMETRY
    BUCHANAN, W
    BARNETT, JM
    CUCHENS, M
    [J]. JOURNAL OF DENTAL RESEARCH, 1983, 62 : 279 - 279
  • [39] EVALUATION OF PLATELET SURFACE-ANTIGENS BY FLUORESCENCE FLOW-CYTOMETRY
    ADELMAN, B
    CARLSON, P
    HANDIN, RI
    [J]. METHODS IN ENZYMOLOGY, 1992, 215 : 420 - 427
  • [40] FLUORESCENCE FLOW-CYTOMETRY IN THE STUDY OF LYMPHOID-CELL RECEPTORS
    SEGAL, DM
    TITUS, JA
    STEPHANY, DA
    [J]. METHODS IN ENZYMOLOGY, 1987, 150 : 478 - 492