MAGNETIZATION TRANSFER CONTRAST IN FAT-SUPPRESSED STEADY-STATE 3-DIMENSIONAL MR IMAGES

被引:25
|
作者
FLAMIG, DP
PIERCE, WB
HARMS, SE
GRIFFEY, RH
机构
[1] Department of Radiology, Mri, Baylor University Medical Center, Dallas, Texas
关键词
D O I
10.1002/mrm.1910260113
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We demonstrate that magnetization transfer contrast can be used to improve the diagnostic utility of fat‐suppressed steady‐state three‐dimensional gradient‐recalled images. Fat suppression is achieved using a “jump‐return” pair of contiguous shaped pulses. No time interval exists between the pulses, and no RF echo is generated. The sequence normally produces images with “density” weighting. Preparation of the spin magnetization with off‐resonance frequency‐selective excitation creates magnetization transfer contrast which attenuates signal intensity in proportion to the exchange rate of magnetization from free water with magnetization from water bound to macromolecules or protons that have restricted mobility. The resulting images have excellent fat suppression with low sensitivity to motion since no subtraction is used. In addition, the mechanism of signal attenuation is independent of paramagnetic effects, and addition of Gd‐DTPA produces signal enhancement from vascularized regions of tissue. Examples are presented for the knee and breast, where the observation of pathology with signal enhancement from Gd‐DTPA is improved over conventional 3D fat‐suppressed images. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:122 / 131
页数:10
相关论文
共 50 条
  • [21] Steady-state imaging with inhomogeneous magnetization transfer contrast using multiband radiofrequency pulses
    Malik, Shaihan J.
    Teixeira, Rui P. A. G.
    West, Daniel J.
    Wood, Tobias C.
    Hajnal, Joseph V.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (03) : 935 - 949
  • [22] 3-DIMENSIONAL STEADY-STATE MODEL OF THE CONNECTICUT YANKEE CORE
    WILEY, RA
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1983, 45 : 733 - 735
  • [23] Chronic tibiofibular syndesmosis injury of ankle: Evaluation with contrast-enhanced fat-suppressed 3D fast spoiled gradient-recalled acquisition in the steady state MR imaging
    Kim, Sungjun
    Huh, Yong-Min
    Song, Ho-Taek
    Lee, Sung-Ah
    Lee, Jin-Woo
    Lee, Jong Eun
    Chung, In Hyuk
    Suh, Jin-Suck
    [J]. RADIOLOGY, 2007, 242 (01) : 225 - 235
  • [24] NUMERICAL TECHNIQUES FOR 3-DIMENSIONAL STEADY-STATE FLUID STRUCTURE INTERACTION
    MATHEWS, IC
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1986, 79 (05): : 1317 - 1325
  • [25] Comparison of breast density measured on MR images acquired using fat-suppressed versus nonfat-suppressed sequences
    Chang, Daniel H. -E.
    Chen, Jeon-Hor
    Lin, Muqing
    Bahri, Shadfar
    Yu, Hon J.
    Mehta, Rita S.
    Nie, Ke
    Hsiang, David J. B.
    Nalcioglu, Orhan
    Su, Min-Ying
    [J]. MEDICAL PHYSICS, 2011, 38 (11) : 5961 - 5968
  • [26] 3-DIMENSIONAL STEADY-STATE TEMPERATURE DISTRIBUTION ABOUT CYLINDERS AND DISCS
    RIDGEWAY, D
    [J]. BULLETIN OF MATHEMATICAL BIOPHYSICS, 1968, 30 (04): : 701 - &
  • [27] 3-DIMENSIONAL STEADY-STATE INDENTATION PROBLEM FOR A GENERAL VISCOELASTIC MATERIAL
    GOLDEN, JM
    GRAHAM, GAC
    LAN, Q
    [J]. QUARTERLY OF APPLIED MATHEMATICS, 1994, 52 (03) : 449 - 468
  • [28] ON OBTAINING THE STEADY-STATE SOLUTIONS OF THE LINEARIZED 3-DIMENSIONAL HYDRODYNAMIC EQUATIONS
    HUNTER, JR
    HEARN, CJ
    [J]. APPLIED MATHEMATICAL MODELLING, 1991, 15 (04) : 200 - 208
  • [30] Fat-suppressed MR Imaging of the Spine for Metal Artifact Reduction at 3T: Comparison of STIR and Slice Encoding for Metal Artifact Correction Fat-suppressed T2-weighted Images
    Lee, Young Han
    Hahn, Seok
    Kim, Eunju
    Suh, Jin-Suck
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (04) : 371 - 378