INCREASED HEATING BY DIAGNOSTIC ULTRASOUND DUE TO NONLINEAR PROPAGATION

被引:55
|
作者
BACON, DR [1 ]
CARSTENSEN, EL [1 ]
机构
[1] UNIV ROCHESTER,ROCHESTER CTR BIOMED ULTRASOUND,ROCHESTER,NY 14627
来源
关键词
D O I
10.1121/1.399950
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The heating of tissues by the absorption of ultrasound is an important safety consideration in the use of diagnostic ultrasound. This paper shows that models of ultrasonic heating for this situation need to take account of nonlinear propagation. Measurements were made of the temperature rise in a sample of tissue-mimicking gel, caused by the application of 3.6-MHz focused ultrasonic beams for 3 min. The propagation path to the focus was in water, to mimic the situation where the fetus is scanned through the full bladder. The effect of nonlinear propagation was seen by changing the pressure amplitude of the pulse, while altering the pulsing regime to preserve a constant spatial-peak temporal-average intensity of 1 W cm- 2. When nonlinear distortion was present, an enhancement in the temperature rise was observed, which correlated with the value of the shock parameter. The enhancement ratio was typically up to a factor of 3, and the maximum temperature rise observed was 2 °C. This enhanced heating was seen both at the surface of the tissue-mimicking gel and after propagation through 23 mm of the material. Under conditions of nonlinear propagation, the maximum heating usually occurs in the prefocal region, rather than at the focus. © 1990, Acoustical Society of America. All rights reserved.
引用
收藏
页码:26 / 34
页数:9
相关论文
共 50 条
  • [31] Simulation of Nonlinear Ultrasound Wave Propagation in Fourier Domain
    Varray, F.
    Basset, O.
    Cachard, C.
    RECENT DEVELOPMENTS IN NONLINEAR ACOUSTICS, 2015, 1685
  • [32] NONLINEAR PROPAGATION OF ULTRASOUND IN SUPERFLUID HE-3
    DEVEGVAR, PGN
    JOURNAL OF STATISTICAL PHYSICS, 1985, 39 (5-6) : 675 - 685
  • [33] THE ROLE OF NONLINEAR ULTRASOUND PROPAGATION DURING HYPERTHERMIA TREATMENTS
    HYNYNEN, K
    MEDICAL PHYSICS, 1991, 18 (06) : 1156 - 1163
  • [34] Effect of Tissue Inhomogeneity on Nonlinear Propagation of Focused Ultrasound
    Liu Zhen-Bo
    Fan Ting-Bo
    Guo Xia-Sheng
    Zhang Dong
    CHINESE PHYSICS LETTERS, 2010, 27 (09)
  • [35] In vitro heating of human fetal vertebra by pulsed diagnostic ultrasound
    Doody, C
    Porter, H
    Duck, FA
    Humphrey, VF
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (08): : 1289 - 1294
  • [36] Time to threshold (TT), a safety parameter for heating by diagnostic ultrasound
    Lubbers, J
    Hekkenberg, RT
    Bezemer, RA
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (05): : 755 - 764
  • [37] ERRORS IN ATTENUATION MEASUREMENTS DUE TO NONLINEAR PROPAGATION EFFECTS
    ZEQIRI, B
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 91 (05): : 2585 - 2593
  • [38] Modifications to the lidar equation due to nonlinear propagation in air
    Faye, G
    Kasparian, J
    Sauerbrey, R
    APPLIED PHYSICS B-LASERS AND OPTICS, 2001, 73 (02): : 157 - 163
  • [39] Modifications to the lidar equation due to nonlinear propagation in air
    G. Faye
    J. Kasparian
    R. Sauerbrey
    Applied Physics B, 2001, 73 : 157 - 163
  • [40] Effect on ultrasound propagation in metal rods due to contact with liquid
    Kumar, Y
    Kumar, A
    Kumar, B
    ACUSTICA, 1997, 83 (01): : 78 - 81