DESIGN STUDY OF A HIGH-RESOLUTION SOFT-X-RAY MONOCHROMATOR WITH A MOVABLE VARIABLE GROOVE DENSITY GRATING

被引:11
|
作者
HOCHST, H
BISSEN, M
ENGELHARDT, MA
CROSSLEY, D
机构
[1] Synchrotron Radiation Center, University of Wisconsin-Madison, Stoughton
基金
美国国家科学基金会;
关键词
D O I
10.1016/0168-9002(92)90542-C
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We discuss the design and optimization of a fixed slit, single element spherical grating monochromator. A novel scheme utilizes the translation and rotation of a grating with a polynomial groove density variation. Optimization of the grating parameters minimizes the major aberration terms and linearizes the total energy resolution over the scan range. With a grating slope error of 0.2" the resolving power ranges from E/DELTA-E greater-than-or-equal-to 10(4) to 5 x 10(3) over the energy range of 500 to 1100 eV.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 50 条
  • [21] THE HIGH-RESOLUTION SOFT-X-RAY SPECTRUM OF HZ 43
    PAERELS, FBS
    BLEEKER, JAM
    BRINKMAN, AC
    GRONENSCHILD, EHBM
    HEISE, J
    ASTROPHYSICAL JOURNAL, 1986, 308 (01): : 190 - 198
  • [22] CONFERENCE SUMMARY - HIGH-RESOLUTION SOFT-X-RAY OPTICS
    FRANKS, A
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 316 : 211 - 213
  • [23] HIGH-RESOLUTION SOFT-X-RAY SPECTROSCOPIES WITH THE DRAGON BEAMLINE
    CHEN, CT
    SETTE, F
    PHYSICA SCRIPTA, 1990, T31 : 119 - 126
  • [24] SOFT-X-RAY MONOCHROMATOR WITH A VARIED-SPACE PLANE GRATING FOR SYNCHROTRON RADIATION - DESIGN AND EVALUATION
    ITOU, M
    HARADA, T
    KITA, T
    APPLIED OPTICS, 1989, 28 (01): : 146 - 153
  • [25] A 10-M GRAZING-INCIDENCE MONOCHROMATOR FOR HIGH-RESOLUTION SOFT-X-RAY SPECTROSCOPY AT THE PHOTON FACTORY
    MAEZAWA, H
    NAKAI, S
    MITANI, S
    NODA, H
    NAMIOKA, T
    SASAKI, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 310 - 313
  • [26] STATUS AND PERSPECTIVES OF HIGH-RESOLUTION SPECTROSCOPY IN THE SOFT-X-RAY RANGE
    KAINDL, G
    DOMKE, M
    LAUBSCHAT, C
    WESCHKE, E
    XUE, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 1234 - 1240
  • [27] OPTIMIZATION OF THE ROWLAND CIRCLE GRATING FOR HIGH-RESOLUTION ASTROPHYSICAL SPECTROMETERS WORKING AT SOFT-X-RAY AND EUV WAVELENGTHS
    MEEKINS, JF
    GURSKY, H
    CRUDDACE, RG
    APPLIED OPTICS, 1985, 24 (18): : 2987 - 2995
  • [28] A high resolution soft X-ray monochromator focused by the holographic effect of a VLS grating
    Polack, Francois
    Lagarde, Bruno
    Idir, Mourad
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 655 - +
  • [29] HIGH-VACUUM 2 CRYSTAL SOFT-X-RAY MONOCHROMATOR
    LEMONNIER, M
    COLLET, O
    DEPAUTEX, C
    ESTEVA, JM
    RAOUX, D
    NUCLEAR INSTRUMENTS & METHODS, 1978, 152 (01): : 109 - 111
  • [30] HIGH-RESOLUTION MICROCHEMICAL ANALYSIS USING SOFT-X-RAY LITHOGRAPHIC TECHNIQUES
    MCGOWAN, JW
    BORWEIN, B
    MEDEIROS, JA
    BEVERIDGE, T
    BROWN, JD
    SPILLER, E
    FEDER, R
    TOPALIAN, J
    GUDAT, W
    JOURNAL OF CELL BIOLOGY, 1979, 80 (03): : 732 - 735