AN ANALYTICAL APPROACH FOR COMPENSATION OF NONUNIFORM ATTENUATION IN CARDIAC SPECT IMAGING

被引:8
|
作者
GLICK, SJ
KING, MA
PAN, TS
SOARES, EJ
机构
[1] Massachusetts Univ., Med. Center, Worcester, MA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1995年 / 40卷 / 10期
关键词
D O I
10.1088/0031-9155/40/10/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Photon attenuation can reduce the diagnostic accuracy of cardiac SPECT imaging. Bellini et nl have previously derived a mathematically exact method to compensate for attenuation in a uniform attenuator. Since the human thorax contains structures with differing attenuation properties, non-uniform attenuation compensation is required in cardiac SPECT. Given an estimate of the patient attenuation map, we show that the Bellini attenuation compensation method can be used in cardiac SPECT to provide a quantitatively accurate reconstruction of a central region in the image which includes the heart and surrounding soft tissue. Simulations using a mathematical cardiac-torso phantom were conducted to evaluate the Bellini method and to compare its performance to the ML-EM iterative algorithm, and to 180 degrees and 360 degrees filtered backprojection (FBP) with no attenuation compensation. 'Bulls-eye' polar maps and circumferential profiles showed that both the Bellini method and the ML-EM algorithm provided quantitatively accurate reconstructions of the myocardium, with a substantial reduction in attenuation-induced artifacts that were observed in the FBP images. The computational load required to implement the Bellini method is approximately equivalent to that required for one iteration of the ML-EM algorithm, thus it is suitable for routine clinical use.
引用
收藏
页码:1677 / 1693
页数:17
相关论文
共 50 条
  • [41] Evaluation of SPECT myocardial lesion detectability with and without nonuniform attenuation compensation using an anthropomorphic female phantom
    Jang, S
    Jaszczak, RJ
    Tsui, BMW
    Metz, CE
    Gilland, DR
    Turkington, TG
    Coleman, RE
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 998 - 1002
  • [42] An analytical algorithm for skew-slit imaging geometry with nonuniform attenuation correction
    Huang, Q
    Zeng, GSL
    MEDICAL PHYSICS, 2006, 33 (04) : 997 - 1004
  • [43] RATIONAL-GAIN-COMPENSATION FOR ATTENUATION IN ULTRASONIC CARDIAC IMAGING
    MELTON, HE
    SKORTON, DJ
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1982, 29 (03): : 183 - 183
  • [44] DIAGNOSTIC-ACCURACY OF ATTENUATION CORRECTED CARDIAC SPECT PERFUSION IMAGING
    FICARO, EF
    FESSLER, JA
    SHREVE, PD
    KRITZMAN, JN
    ROSE, PA
    CORBETT, JR
    CIRCULATION, 1995, 92 (08) : 50 - 50
  • [45] CORRECTION FOR PHOTON ATTENUATION IN SPECT - ANALYTICAL FRAMEWORK, AVERAGE ATTENUATION FACTORS, AND A NEW HYBRID APPROACH
    PAN, XC
    WONG, WH
    CHEN, CT
    LIU, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (09): : 1219 - 1234
  • [46] Is Transmission-Gating Necessary for Cardiac SPECT Imaging with Attenuation Correction?
    Bai, Chuanyong
    Conwell, Richard
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2703 - 2709
  • [47] EXTENDED ACQUISITION FOR MINIMIZING ATTENUATION ARTIFACT IN SPECT CARDIAC PERFUSION IMAGING
    BATEMAN, TM
    KOLOBRODOV, VV
    VASIN, AP
    OKEEFE, JH
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (04) : 625 - 627
  • [48] Evaluation of the effects of patient arm attenuation in SPECT cardiac perfusion imaging
    Luo, DS
    King, MA
    Pan, TS
    Xia, WS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3291 - 3299
  • [49] SPECT QUANTIFICATION - A SIMPLIFIED METHOD OF ATTENUATION AND SCATTER CORRECTION FOR CARDIAC IMAGING
    GALT, JR
    CULLOM, SJ
    GARCIA, EV
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (12) : 2232 - 2237
  • [50] Improvement of lesion contrast with nonuniform attenuation correction in ga-67 thoracic spect Imaging
    Sato, J.
    Shuke, N.
    Sugimori, H.
    Uno, T.
    Okizaki, A.
    Takahashi, K.
    Aburano, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S342 - S342