AN ANALYTICAL APPROACH FOR COMPENSATION OF NONUNIFORM ATTENUATION IN CARDIAC SPECT IMAGING

被引:8
|
作者
GLICK, SJ
KING, MA
PAN, TS
SOARES, EJ
机构
[1] Massachusetts Univ., Med. Center, Worcester, MA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1995年 / 40卷 / 10期
关键词
D O I
10.1088/0031-9155/40/10/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Photon attenuation can reduce the diagnostic accuracy of cardiac SPECT imaging. Bellini et nl have previously derived a mathematically exact method to compensate for attenuation in a uniform attenuator. Since the human thorax contains structures with differing attenuation properties, non-uniform attenuation compensation is required in cardiac SPECT. Given an estimate of the patient attenuation map, we show that the Bellini attenuation compensation method can be used in cardiac SPECT to provide a quantitatively accurate reconstruction of a central region in the image which includes the heart and surrounding soft tissue. Simulations using a mathematical cardiac-torso phantom were conducted to evaluate the Bellini method and to compare its performance to the ML-EM iterative algorithm, and to 180 degrees and 360 degrees filtered backprojection (FBP) with no attenuation compensation. 'Bulls-eye' polar maps and circumferential profiles showed that both the Bellini method and the ML-EM algorithm provided quantitatively accurate reconstructions of the myocardium, with a substantial reduction in attenuation-induced artifacts that were observed in the FBP images. The computational load required to implement the Bellini method is approximately equivalent to that required for one iteration of the ML-EM algorithm, thus it is suitable for routine clinical use.
引用
收藏
页码:1677 / 1693
页数:17
相关论文
共 50 条
  • [1] An analytical approach for compensation of non-uniform attenuation in cardiac SPECT imaging
    Glick, SJ
    King, MA
    Pan, TS
    Soares, EJ
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1713 - 1717
  • [2] Analytical approach for compensation of non-uniform attenuation in cardiac SPECT imaging
    Glick, S.J.
    King, M.A.
    Pan, Tin-Su
    Soares, E.J.
    Physics in Medicine and Biology, 1995, 40 (10):
  • [3] COMPENSATION FOR NONUNIFORM ATTENUATION IN SPECT BRAIN IMAGING
    GLICK, SJ
    KING, MA
    PAN, TS
    LICHO, R
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P188 - P188
  • [4] Compensation for nonuniform attenuation in SPECT brain imaging
    Univ of Massachusetts Medical Cent, Worcester, United States
    IEEE Trans Nucl Sci, 2 pt 2 (737-750):
  • [5] Compensation for nonuniform attenuation in SPECT brain imaging
    Glick, SJ
    King, MA
    Pan, TS
    Soares, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (02) : 737 - 750
  • [6] CORRECTION OF NONUNIFORM ATTENUATION IN CARDIAC SPECT IMAGING
    TSUI, BMW
    GULLBERG, GT
    EDGERTON, ER
    BALLARD, JG
    PERRY, JR
    MCCARTNEY, WH
    BERG, J
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (04) : 497 - 507
  • [7] An analytical approach of compensation for non-uniform attenuation and 3D detector response in cardiac SPECT imaging
    Glick, SJ
    King, MA
    Pan, TS
    Soares, EJ
    THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 : 133 - 148
  • [8] THE IMPORTANCE OF ATTENUATION COMPENSATION AND ITS IMPLEMENTATION IN CARDIAC SPECT IMAGING
    TSUI, BMW
    ZHAO, XD
    LI, J
    MCCARTNEY, WH
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P30 - P30
  • [9] Spect nonuniform attenuation compensation using transmission CT attenuation maps
    Jaszczak, RJ
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 : SH503 - SH503
  • [10] Energy-based compensation for nonuniform attenuation in Ga-67SPECT imaging
    Moore, SC
    Müller, SP
    Kijewski, MF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1149 - 1154