Dose volume histogram analysis and comparison of different radiobiological models using in-house developed software

被引:46
|
作者
Oinam, Arun S. [1 ]
Singh, Lakhwant [2 ]
Shukla, Arvind [1 ]
Ghoshal, Sushmita [1 ]
Kapoor, Rakesh [1 ]
Sharma, Suresh C. [1 ]
机构
[1] Post Grad Inst & Med Educ & Res, Dept Radiotherapy, Chandigarh, India
[2] Guru Nanak Dev Univ, Dept Phys, Amritsar, Punjab, India
关键词
Niemierko model; normal tissue complication probability; Poisson-based model and Lyman-Kutcher-Burman model; tumor control probability;
D O I
10.4103/0971-6203.89971
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to compare Lyman-Kutcher-Burman (LKB) model versus Niemierko model for normal tissue complication probability (NTCP) calculation and Niemierko model versus Poisson-based model for tumor control probability (TCP) calculation in the ranking of different treatment plans for a patient undergoing radiotherapy. The standard normal tissue tolerance data were used to test the NTCP models. LKB model can reproduce the same complication probability data of normal tissue response on radiation, whereas Niemierko model cannot reproduce the same complication probability. Both Poisson-based and Niemierko models equally reproduce the same standard TCP data in testing of TCR In case of clinical data generated from treatment planning system, NTCP calculated using LKB model was found to be different from that calculated using Niemierko model. When the fractionation effect was considered in LKB model, the calculated values of NTCPs were different but comparable with those of Niemierko model. In case of TCP calculation using these models, Poisson-based model calculated marginally higher control probability as compared to Niemierko model.
引用
收藏
页码:220 / 229
页数:10
相关论文
共 50 条
  • [1] An in-house developed software for generalised deflection analysis of a stepped shaft
    Datta, D.
    Bandyopadhyay, P.
    [J]. Journal of the Institution of Engineers (India): Mechanical Engineering Division, 2001, 82 (02): : 47 - 51
  • [2] Waste-to-Energy Systems Modelling Using In-House Developed Software
    Kropac, Jiri
    Pavlas, Martin
    Fusek, Michal
    Klimek, Petr
    Tous, Michal
    [J]. PRES 2011: 14TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1 AND 2, 2011, 25 : 533 - +
  • [3] Investigation of LabVIEW and Syslog Interface using In-house Developed Generic Logging Software
    Kaur, G.
    Sugandhi, R.
    Trivedi, S.
    Srivastava, Prabhakar
    Awasthi, L. M.
    [J]. 2019 INNOVATIONS IN POWER AND ADVANCED COMPUTING TECHNOLOGIES (I-PACT), 2019,
  • [4] The effect of the different uncertainty models in dose expected volume histogram computation
    F. Cutanda Henríquez
    S. Vargas Castrillón
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2008, 31 : 196 - 202
  • [5] The effect of the different uncertainty models in dose expected volume histogram computation
    Henriquez, F. Cutanda
    Castrillon, S. Vargas
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2008, 31 (03) : 196 - 202
  • [6] Variations of Dose Volume Histogram Calculated Using MiM and Eclipse Software
    Geng, H.
    Zhong, H.
    Huang, M.
    O'Grady, F.
    Cheng, C.
    Ryu, S.
    Yin, F.
    Xiao, Y.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2918 - 2918
  • [7] Dose Volume Histogram (DVH) Analysis Software for Radiation Therapy Research
    Jang, S.
    Pyakuryal, A.
    Myint, K.
    Mittal, B.
    Gopalakrishnan, M.
    Curran, B.
    Sternick, E.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [8] RadDeploy: A framework for integrating in-house developed software and artificial intelligence models seamlessly into radiotherapy workflows
    Rasmussen, Mathis Ersted
    Vestergaard, Casper Dueholm
    Kallehauge, Jesper Folsted
    Ren, Jintao
    Guldberg, Maiken Haislund
    Orrevang, Ole N.
    Elstr, Ulrik Vindelev
    Korreman, Stine Sofia
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [9] PREDICTION AND COMPARISON OF CRITICAL SPEEDS AND POTENTIAL EXCITATION USING IN-HOUSE DEVELOPED SOFTWARE FOR AN INTEGRALLY GEARED CENTRIFUGAL AIR COMPRESSOR
    James, Mathew P.
    Pandillapalli, Pavan Kumar Reddy
    Gopalakrishnan, Swaminathan
    [J]. PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2014, 2014,
  • [10] Comparison of two deformable registration software using an in-house "deformable phantom"
    Koutsouvelis, N.
    Rouzaud, M.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 838 - 839