The effect of the different uncertainty models in dose expected volume histogram computation

被引:4
|
作者
Henriquez, F. Cutanda [1 ]
Castrillon, S. Vargas [2 ]
机构
[1] Univ Gregorio Maranon, Gen Hosp, Nucl Med Serv, Madrid 28007, Spain
[2] Sci & Educ Minist, Madrid, Spain
关键词
dose uncertainty; dose distribution; dose expected volume histogram; treatment planning system; probability distribution;
D O I
10.1007/BF03179344
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dose expected volume histograms are a useful alternative to dose volume histograms in order to take into account computation uncertainty when prescribing, planning and reporting external beam radiation therapy. Due to the type B nature of computation uncertainties, a rectangular probability distribution was assumed in its definition. In the present work, the changes of dose expected volume histograms when using other recommended point dose uncertainty models are investigated. Results show that the choice of probability distribution, among the ones recommended for uncertainty modelling, has a small effect on the result. Thus, the standard uncertainty of point dose computations is the main parameter affecting dose expected volume histograms.
引用
下载
收藏
页码:196 / 202
页数:7
相关论文
共 50 条
  • [1] The effect of the different uncertainty models in dose expected volume histogram computation
    F. Cutanda Henríquez
    S. Vargas Castrillón
    Australasian Physics & Engineering Sciences in Medicine, 2008, 31 : 196 - 202
  • [2] A novel method for the evaluation of uncertainty in dose-volume histogram computation
    Henríquez, Francisco Cutanda
    Castrillon, Silvia Vargas
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1263 - 1271
  • [3] Confidence intervals in dose volume histogram computation
    Cutanda Henriquez, Francisco
    Vargas Castrillon, Silvia
    MEDICAL PHYSICS, 2010, 37 (04) : 1545 - 1553
  • [4] Developing a dose-volume histogram computation program for brachytherapy
    Panitsa, E
    Rosenwald, JC
    Kappas, C
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08): : 2109 - 2121
  • [5] Dose volume histogram analysis and comparison of different radiobiological models using in-house developed software
    Oinam, Arun S.
    Singh, Lakhwant
    Shukla, Arvind
    Ghoshal, Sushmita
    Kapoor, Rakesh
    Sharma, Suresh C.
    JOURNAL OF MEDICAL PHYSICS, 2011, 36 (04) : 220 - 229
  • [6] Computation of the expected volume of a random manifold
    Zaporozhets D.N.
    Journal of Mathematical Sciences, 2006, 133 (3) : 1282 - 1289
  • [7] A method to vectorize the dose distribution, the dose volume histogram and create a dose vector histogram
    Mayo, Charles S.
    Zankowski, Corey
    Herman, Michael
    Miller, Robert
    Olivier, Kenneth
    Vincent, Abhilash
    Suominen, Jukka
    MEDICAL PHYSICS, 2013, 40 (01)
  • [8] QA of Dose-Volume Histogram
    Cheng, C.
    Das, I.
    Srivastava, S.
    Gao, Z.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [9] Compute Unified Device Architecture-Based Parallel Dose-Volume Histogram Computation
    Wang, Yangping
    Deng, Chong
    Li, Lian
    Dang, Jianwu
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (04) : 833 - 840
  • [10] A Method to Vectorize the Dose Distribution, the Dose Volume Histogram
    Mayo, C.
    Zankowski, C.
    Herman, M.
    Miller, R.
    Olivier, K.
    Suominen, J.
    MEDICAL PHYSICS, 2013, 40 (06)