PHASE-I CLINICAL-EVALUATION OF GD-EOB-DTPA AS A HEPATOBILIARY MR CONTRAST AGENT - SAFETY, PHARMACOKINETICS, AND MR-IMAGING

被引:495
|
作者
HAMM, B
STAKS, T
MUHLER, A
BOLLOW, M
TAUPITZ, M
FRENZEL, T
WOLF, KJ
WEINMANN, HJ
LANGE, L
机构
[1] FREE UNIV BERLIN,BENJAMIN FRANKLIN HOSP,DEPT RADIOL,BERLIN,GERMANY
[2] SCHERING AG,RES LABS,W-1000 BERLIN,GERMANY
关键词
CONTRAST MEDIA; EXPERIMENTAL STUDIES; GADOLINIUM; LIVER; MR; MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT;
D O I
10.1148/radiology.195.3.7754011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the safety, pharmacokinetics, and magnetic resonance (MR) imaging results of gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) as a contrast agent for use in hepatobiliary MR imaging. MATERIALS AND METHODS: Gd-EOB-DTPA was tested at doses of 10, 25, 50, and 100 mu mol per kilogram of body weight. Results of laboratory tests, clinical measurements, and pharmacokinetic data were obtained in 44 healthy volunteers in a double-blind, randomized, placebo-controlled design. MR images were obtained in another 16 healthy volunteers before and up to 6 hours after fast intravenous administration of Gd-EOB-DTPA. RESULTS: Gd-EOB-DTPA was well tolerated, with no important side effects or changes in laboratory parameters. Homogeneous enhancement of liver parenchyma was observed immediately after injection of the contrast agent. Peak liver signal intensity was noted 20 minutes after injection, followed by plateaulike enhancement over about 2 hours. The common bile duct was hyperintense within 10 minutes after injection in all volunteers. CONCLUSION: Gd-EOB-DTPA is safe and efficient for MR imaging of the liver.
引用
收藏
页码:785 / 792
页数:8
相关论文
共 50 条
  • [41] Effect of hepatobiliary uptake of Gd-EOB-DTPA on the hepatic venous phase of dynamic magnetic resonance imaging on a 3.0-T apparatus: comparison between Gd-EOB-DTPA and Gd-DTPA
    Fujinaga, Yasunari
    Ohya, Ayumi
    Matsushita, Tsuyoshi
    Kurozumi, Masahiro
    Ueda, Kazuhiko
    Kitou, Yoshihiro
    Ueda, Hitoshi
    Kadoya, Masumi
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (10) : 695 - 700
  • [42] MR imaging of the biliary tract with Gd-EOB-DTPA: Effect of liver function on signal intensity
    Takao, Hidemasa
    Akai, Hiroyuki
    Tajima, Taku
    Kiryu, Shigeru
    Watanabe, Yasushi
    Imamura, Hiroshi
    Akahane, Masaaki
    Yoshioka, Naoki
    Kokudo, Norihiro
    Ohtomo, Kuni
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (02) : 325 - 329
  • [43] Safety and efficacy of a novel hepatobiliary MR contrast agent GN-1140 (Gd-DTPA-DeA): From the results of phase I and phase II clinical trials
    Tanimoto, A
    Kadoya, M
    Kawamura, Y
    Kuwatsuru, R
    Gokan, T
    Hirohashi, S
    ACADEMIC RADIOLOGY, 2002, 9 : S457 - S459
  • [44] GD-DTPA-CASCADE-POLYMER - POTENTIAL BLOOD-POOL CONTRAST AGENT FOR MR-IMAGING
    ADAM, G
    NEUERBURG, J
    SPUNTRUP, E
    MUHLER, A
    SCHERER, K
    GUNTHER, RW
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03): : 462 - 466
  • [45] Radiomics Analysis of MR Imaging with Gd-EOB-DTPA for Preoperative Prediction of Microvascular Invasion in Hepatocellular Carcinoma: Investigation and Comparison of Different Hepatobiliary Phase Delay Times
    Zhang, Shuai
    Xu, Guizhi
    Duan, Chongfeng
    Zhou, Xiaoming
    Wang, Xin
    Yu, Haiyang
    Yu, Lan
    Li, Zhiming
    Gao, Yuanxiang
    Zhao, Ruirui
    Jiao, Linlin
    Wang, Gang
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [46] Assessment of Fast Dynamic Imaging and the Use of Gd-EOB-DTPA for MR-Guided Liver Interventions
    Fischbach, Frank
    Thormann, Markus
    Seidensticker, Max
    Kropf, Siegfried
    Pech, Maciej
    Ricke, Jens
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) : 874 - 879
  • [47] MR liver imaging with Gd-EOB-DTPA: a delay time of 10 minutes is sufficient for lesion characterisation
    C. S. van Kessel
    W. B. Veldhuis
    M. A. A. J. van den Bosch
    M. S. van Leeuwen
    European Radiology, 2012, 22 : 2153 - 2160
  • [48] MR prediction of liver fibrosis using a liver-specific contrast agent: Superparamagnetic iron oxide versus Gd-EOB-DTPA
    Nishie, Akihiro
    Asayama, Yoshiki
    Ishigami, Kousei
    Tajima, Tsuyoshi
    Kakihara, Daisuke
    Nakayama, Tomohiro
    Takayama, Yukihisa
    Okamoto, Daisuke
    Taketomi, Akinobu
    Shirabe, Ken
    Fujita, Nobuhiro
    Obara, Makoto
    Yoshimitsu, Kengo
    Honda, Hiroshi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (03) : 664 - 671
  • [49] MR liver imaging with Gd-EOB-DTPA: a delay time of 10 minutes is sufficient for lesion characterisation
    van Kessel, C. S.
    Veldhuis, W. B.
    van den Bosch, M. A. A. J.
    van Leeuwen, M. S.
    EUROPEAN RADIOLOGY, 2012, 22 (10) : 2153 - 2160
  • [50] Contrast-enhanced MR cholangiography with Gd-EOB-DTPA for preoperative biliary mapping: correlation with intraoperative cholangiography
    Lee, Yedaun
    Kim, So Yeon
    Kim, Kyoung Won
    Lee, Seung Soo
    Park, Seong Ho
    Byun, Jae Ho
    Lee, Moon-Gyu
    ACTA RADIOLOGICA, 2015, 56 (07) : 773 - 781