SEISMIC PERFORMANCE OF STEEL-ENCASED COMPOSITE COLUMNS

被引:102
|
作者
RICLES, JM [1 ]
PABOOJIAN, SD [1 ]
机构
[1] LINDY PROPERTIES,SARATOGA,CA 95070
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 1994年 / 120卷 / 08期
关键词
D O I
10.1061/(ASCE)0733-9445(1994)120:8(2474)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental investigation was conducted to investigate the behavior of composite columns subjected to simulated seismic loading conditions. Eight two-thirds-scale specimens were tested, each consisting of a structural steel shape encased in reinforced concrete. The parameters studied in the test program included the degree of concrete confinement required to achieve adequate ductility under cyclic loading, effectiveness of flange shear studs for enhancing flexural stiffness and strength, concrete compressive strength, and the shear resistance mechanism of the composite column. The results of the test program indicate that encased composite columns possess exceptional cyclic strength and ductility if buckling of the longitudinal reinforcement is inhibited. The encased steel shape was found to provide the primary resistance to transverse shear during overloading, with the shear studs not effective in enhancing the flexural resistance to lateral loading. The specimen flexural capacity under combined axial and lateral loading was found to be accurately predicted by analytical models based on full composite action, with ACI and AISC LRFD criteria providing conservative results.
引用
收藏
页码:2474 / 2494
页数:21
相关论文
共 50 条
  • [21] Seismic performance of reinforced concrete bridge columns encased in fiber composite tube
    Zhu, Z.
    Mirmiran, A.
    Saiidi, M.
    Proc. Int. Conf. Bridge Maint., Saf. Manage. - Bridge Maint., Saf., Manage., Life-Cycle Perform. Cost, 1600, (621-622):
  • [22] Development of partially encased composite columns for use in steel shear walls for seismic applications
    Driver, Robert G.
    2008 SEISMIC ENGINEERING CONFERENCE COMMEMORATING THE 1908 MESSINA AND REGGIO CALABRIA EARTHQUAKE, PTS 1 AND 2, 2008, 1020 : 35 - 42
  • [23] Seismic Behavior of GFRP Tube Reactive Powder Concrete Composite Columns With Encased Steel
    Ji, Jing
    He, Lingjie
    Jiang, Liangqin
    Ren, Hongguo
    Ni, Shuai
    Wang, Zizhen
    Li, Yunhao
    Yu, Chenyu
    Lin, Yubo
    FRONTIERS IN MATERIALS, 2021, 8
  • [24] Simulation of partially encased composite steel-concrete columns with steel columns
    Marinopoulou, A. A.
    Balopoulos, V. D.
    Kalfas, C. N.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (08) : 1058 - 1065
  • [25] Study on Comprehensive Performance of the New-type Steel-encased Concrete Composite Beams Using FEM
    Jiang, Jitong
    Zhu, Xiulan
    Du, Derun
    Dong, Kun
    Yang, Song
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 697 - 701
  • [26] Seismic Performance of Cross-Shaped Partially Encased Steel-Concrete Composite Columns: Experimental and Numerical Investigations
    Xu, Qiuyu
    Liu, Yong
    Wang, Jingfeng
    BUILDINGS, 2024, 14 (07)
  • [27] Structural performance of rigid shear connectors in concrete encased steel composite columns
    Eghbali, Nasrin Bakhshayesh
    Andamnejad, Payam
    STRUCTURES, 2023, 54 : 348 - 368
  • [28] MANUFACTURING OF STEEL-ENCASED STANDARD LARGE DISTRIBUTORS
    WIEBER, A
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1976, 28 (02): : 33 - 35
  • [29] Performance of axially restrained concrete encased steel composite columns at elevated temperatures
    Young, Ben
    Ellobody, Ehab
    ENGINEERING STRUCTURES, 2011, 33 (01) : 245 - 254