LACTATE AND GLUCOSE ELECTROCHEMICAL BIOSENSORS FOR THE EVALUATION OF THE AEROBIC AND ANAEROBIC THRESHOLD IN RUNNERS

被引:46
|
作者
PALLESCHI, G
MASCINI, M
BERNARDI, L
ZEPPILLI, P
机构
[1] UNIV FLORENCE, DIPARTMENTO CHIM ANALIT, I-50121 FLORENCE, ITALY
[2] UNIV CATTOLICA SACRO CUORE, POLICLIN UNIV A GEMELLI, IST CLIN MED, CTR MED SPORT, I-00168 ROME, ITALY
关键词
AEROBIC THRESHOLD; AMPEROMETRY; ANAEROBIC THRESHOLD; HYDROGEN PEROXIDE ELECTRODE;
D O I
10.1007/BF02442677
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Lactate and glucose are measured in whole blood of athletes running on a treadmill by using two extracorporeal electrochemical biosensors. The lactate sensor was fixed to an endocrine artificial pancreas (Betalike) which had been used in previous extracorporeal experiments. The lactate sensor gave a signal which resulted in a well defined curve that allowed the evaluation of the aerobic as well as the anaerobic threshold. The results obtained with the glucose sensor supported the theory that muscle anaerobic glycolysis is dependent on muscle glycogen rather than on blood glucose.
引用
收藏
页码:B25 / B28
页数:4
相关论文
共 50 条
  • [41] RELATIONSHIP OF THE ANAEROBIC THRESHOLD AND RUNNING PERFORMANCE IN FEMALE RECREATIONAL RUNNERS
    CLAIBORNE, JM
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 229 - 229
  • [42] ANAEROBIC THRESHOLD AS A PREDICTOR OF ATHLETIC PERFORMANCE IN YOUNG FEMALE RUNNERS
    WOLFE, RR
    DABERKOW, ED
    WASHINGTON, RL
    MURPHY, JR
    BRAMMEL, HL
    PEDIATRIC RESEARCH, 1981, 15 (04) : 475 - 475
  • [44] Lactate Threshold as a Measure of Aerobic Metabolism in Resistance Exercise
    Dominguez, Raul
    Luis Mate-Munoz, Jose
    Serra-Paya, Noemi
    Vicente Garnacho-Castano, Manuel
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2018, 39 (03) : 163 - 172
  • [45] Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes
    Florescu, M
    Brett, CMA
    TALANTA, 2005, 65 (02) : 306 - 312
  • [46] Evaluation of cobalt hexacyanoferrate modified carbon film electrodes for electrochemical glucose biosensors
    Florescu, Monica
    Brett, Christopher M. A.
    REVUE ROUMAINE DE CHIMIE, 2007, 52 (10) : 969 - +
  • [47] ANAEROBIC THRESHOLD DETERMINATION BY BLOOD LACTATE AND MYOELECTRIC SIGNALS
    NAGATA, A
    MURO, M
    MORITANI, T
    YOSHIDA, T
    JAPANESE JOURNAL OF PHYSIOLOGY, 1981, 31 (04): : 585 - 597
  • [48] Dangerous curves - A perspective on exercise, lactate, and the anaerobic threshold
    Myers, J
    Ashley, E
    CHEST, 1997, 111 (03) : 787 - 795
  • [49] Anaerobic Performance and Lactate Threshold in Paraolympic Rowing Athletes
    Zoppi, Claudio C.
    Schwingel, Paulo A.
    Sa, Cloud Kennedy C.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S242 - S242
  • [50] REPRODUCIBILITY OF POST-EXERCISE LACTATE AND ANAEROBIC THRESHOLD
    FRIC, J
    FRIC, J
    BOLDT, F
    STOBOY, H
    MELLER, W
    FELDT, F
    DRYGAS, W
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1988, 9 (05) : 310 - 312