OPTIMIZATION OF SECONDARY-ION MASS-SPECTROMETRY FOR QUANTITATIVE TRACE ANALYSIS

被引:25
|
作者
STINGEDER, G
机构
[1] Institute for Analytical Chemistry, University of Technology Vienna, A-1060 Vienna
关键词
MASS SPECTROMETRY; SECONDARY ION MS; TRACE ANALYSIS;
D O I
10.1016/0003-2670(94)00054-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potential of dynamic secondary ion mass spectrometry (SIMS) for quantitative trace analysis is evaluated from the basic equations of signal formation and instrumental detection. The key factors are sputtering yield and ionization probability. The aim of optimization of measurement technique for problem solving is to gain maximum relevant quantitative information. In qualitative analysis elemental ions have to be identified and interfering molecular ions are separated by differences in kinetic energy distribution (energy discrimination) or mass (high mass resolution). Due to the complex signal formation process, quantification of intensities is performed by relative sensitivity factors obtained by calibration samples. Practically no certified reference materials are available. Calibration samples can be produced by chemical doping of substances, but routinely ion implantation is applied. Transfer of sensitivity factors between different laboratories respectively utilization of compiled values from the literature leads only to semiquantitative results. The prerequisite for accurate quantitative analysis are low random errors and reduction, preferably elimination of systematic errors. In an empirical problem oriented approach, variation of measurement parameters, use of different calibration methods and analytical techniques are combined to achieve optimum or maximum accuracy or information. For homogeneous samples a reproducibility of typically +/- 2%rel. and an accuracy of +/- 5%rel. can be obtained. Matrix and charging effects can severely limit SIMS analysis. Our experiences to control these effects are discussed. The course of the surface charge during depth profiling of a layer system can yield additional information on the quality of insulating layers. Examples for elimination of the matrix effect by flooding the surface with oxygen and by utilizing the energy distribution of the secondary ions are presented. Some references are given for the combination of SIMS depth profiling with imaging methods like electron probe micro analysis (EMPA), scanning tunneling microscopy (STM), atomic force microscopy (AFM), and transmission electron microscopy (TEM) to gain additional information.
引用
收藏
页码:231 / 251
页数:21
相关论文
共 50 条
  • [31] IDENTIFICATION OF MODIFIED NUCLEOSIDES BY SECONDARY-ION MASS-SPECTROMETRY
    UNGER, SE
    SCHOEN, AE
    COOKS, RG
    ASHWORTH, DJ
    GOMES, JD
    CHANG, CJ
    JOURNAL OF ORGANIC CHEMISTRY, 1981, 46 (23): : 4765 - 4769
  • [32] LIMITING FACTORS FOR SECONDARY-ION MASS-SPECTROMETRY PROFILING
    CIRLIN, EH
    VAJO, JJ
    HASENBERG, TC
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1994, 12 (01): : 269 - 275
  • [33] QUANTITATIVE TRACE-ELEMENT ANALYSIS OF MICRODROPLET RESIDUES BY SECONDARY ION MASS-SPECTROMETRY
    ODOM, RW
    LUX, G
    FLEMING, RH
    CHU, PK
    NIEMEYER, IC
    BLATTNER, RJ
    ANALYTICAL CHEMISTRY, 1988, 60 (19) : 2070 - 2075
  • [34] QUANTITATIVE SECONDARY ION MASS-SPECTROMETRY
    GRASSERBAUER, M
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (03): : 510 - 518
  • [35] ANALYSIS OF HYDROGEN ISOTOPES IN MATERIALS BY SECONDARY-ION MASS-SPECTROMETRY AND NUCLEAR MICROANALYSIS
    ROSS, GG
    VACUUM, 1994, 45 (04) : 375 - 387
  • [36] NEGATIVE METAL-ION SOURCE FOR SECONDARY-ION MASS-SPECTROMETRY
    YURIMOTO, H
    MORI, Y
    YAMAMOTO, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (05): : 1146 - 1149
  • [37] INSITU ION-IMPLANTATION FOR QUANTIFICATION IN SECONDARY-ION MASS-SPECTROMETRY
    GNASER, H
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 333 (4-5): : 507 - 510
  • [38] LIQUID SECONDARY-ION MASS-SPECTROMETRY FOURIER-TRANSFORM MASS-SPECTROMETRY OF OLIGOSACCHARIDE ANIONS
    CARROLL, JA
    NGOKA, L
    BEGGS, CG
    LEBRILLA, CB
    ANALYTICAL CHEMISTRY, 1993, 65 (11) : 1582 - 1587
  • [39] THE INFLUENCE OF OXYGEN ON THE ANALYSIS OF A PT/SI STRUCTURE WITH SECONDARY-ION MASS-SPECTROMETRY
    ELST, K
    VANDERVORST, W
    JOURNAL OF APPLIED PHYSICS, 1993, 73 (09) : 4649 - 4659
  • [40] FAST-ATOM MOLECULAR SECONDARY-ION MASS-SPECTROMETRY
    ROSS, MM
    WYATT, JR
    COLTON, RJ
    CAMPANA, JE
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 54 (03): : 237 - 247