Evaluation of the response of a "Long-Counter" for Am-241/Be neutrons

被引:2
|
作者
Federico, Claudio Antonio [1 ]
de Oliveira, Wagner Aguiar [1 ]
Pereira, Marlon Antonio [1 ]
Goncalez, Odair Lelis [1 ]
机构
[1] Inst Adv Studies, Sao Jose Dos Campos, Brazil
关键词
Neutron; Cosmic radiation; Fluency;
D O I
10.5028/jatm.2009.0102243246
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
A "Long-Counter" neutron detector is being used in the context of the DREAB (Dosimetry of the Radiation in the Brazilian Airspace) project to monitor the integral flow of neutrons deriving from the interaction of cosmic radiation with the atmosphere, which is important for measuring radiation doses received by humans at ground level and is mainly responsible for doses received by aircraft crews and sensitive instrumentation. In this work the preliminary tests performed with the Long-Counter neutron detector are presented using a 241Am/Be neutron source where the radial and transversal directional dependence of the equipment was evaluated and also an additional backward-shield in the equipment was verified, as a way of minimizing the back nodule response in relation to the frontal nodule, which is a condition of interest for the current work in progress.
引用
收藏
页码:243 / 246
页数:4
相关论文
共 50 条
  • [31] NUCLEAR MOMENTS OF AM-241 AND AM-243
    MANNING, TE
    FRED, M
    TOMKINS, FS
    [J]. PHYSICAL REVIEW, 1956, 102 (04): : 1108 - 1108
  • [32] LONG-TERM RETENTION OF AM-241 FOLLOWING ACCIDENTAL INHALATION
    FRY, FA
    [J]. HEALTH PHYSICS, 1976, 31 (01): : 13 - 20
  • [33] EFFECTIVE CENTER LONG-COUNTER
    HEINZELMANN, M
    ROHLOFF, F
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1973, 109 (02): : 205 - 210
  • [34] SPECTROMETRY AND DOSIMETRIC EVALUATION OF THE GAMMA-RAY EMISSIONS OF AM-241
    BRADLEY, DA
    CHONG, CS
    [J]. APPLIED RADIATION AND ISOTOPES, 1991, 42 (08) : 767 - 770
  • [35] EVALUATION OF METHODS FOR THE RADIOMETRIC MEASUREMENT OF AM-241 IN ENVIRONMENTAL-SAMPLES
    LIVENS, FR
    SINGLETON, DL
    [J]. ANALYST, 1989, 114 (09) : 1097 - 1101
  • [36] ABSOLUTE MEASUREMENTS OF THE CROSS-SECTION FOR THE FISSION OF AM-241 BY 2.5-MEV NEUTRONS
    ALEKSANDROV, BM
    NEMILOV, YA
    SELITSKII, YA
    SOLOVEV, SM
    FUNSHTEIN, VB
    KHLEBNIKOV, SV
    SHIRYAEV, BM
    [J]. SOVIET ATOMIC ENERGY, 1979, 46 (06): : 475 - 476
  • [37] BIOPHYSICAL ASPECTS OF AM-241 AND PU-241 IN ENVIRONMENT
    HOLM, E
    PERSSON, RBR
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1978, 15 (03) : 261 - 276
  • [38] Evaluation of the Response of a Neutron Detector of the Long-Counter Type Using Monte Carlo Transport Simulation
    Pazianotto, M. T.
    Goncalez, O. L.
    Federico, C. A.
    Carlson, B. V.
    [J]. XXXIII BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2011, 1351
  • [39] THE INFLUENCE OF AEROSOL SIZE ON RETENTION AND TRANSLOCATION OF AM-241 FOLLOWING INHALATION OF (AMO2)-AM-241 BY BEAGLES
    MEWHINNEY, JA
    GRIFFITH, WC
    MUGGENBURG, BA
    [J]. HEALTH PHYSICS, 1982, 42 (05): : 611 - 627
  • [40] INHALATION TOXICOLOGY OF [AM(NO3)3]-AM-241
    GIES, RA
    BALLOU, JE
    [J]. HEALTH PHYSICS, 1980, 39 (06): : 1048 - 1048