AN ELECTRON-BEAM CT APPROACH FOR TRANSVENOUS CORONARY ARTERIOGRAPHY

被引:11
|
作者
THOMAS, PJ
MCCOLLOUGH, CH
RITMAN, EL
机构
[1] MAYO CLIN & MAYO FDN,DEPT PHYSIOL & BIOPHYS,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,DEPT DIAGNOST RADIOL,ROCHESTER,MN 55905
关键词
COMPUTED TOMOGRAPHY; 3-DIMENSIONAL; TECHNIQUES; ANGIOGRAPHY;
D O I
10.1097/00004728-199505000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The goal is to image the 3D anatomy of the major coronary arteries within a single breath-hold and using a single intravenous injection of contrast agent. Materials and Methods: With use of an electron-beam CT (EBCT) scanner, operated in its multislice scan mode (using all four target rings, each scanning two nominal 8 mm thick slices in a total time interval of 224 ms), a radiologically realistic thorax phantom containing a heart with coronary arteries (opacified with 40 mg iodine/ml) was scanned six times with the patient table advanced by a 2 mm step into the scanner between each scan. The normalized and scaled sinogram data were transferred to an off-line computer and reconstructed using our own implementation of a 3D algebraic reconstruction technique that takes into account the exact 3D relationship of the X-ray source and detector elements of the EBCT. Results: A single volume image consisting of 40 slices, at 2 mm intervals and each uniformly 3.7 mm thick, depicted the lumina of the coronary arteries with greater anatomic detail than the ''original'' images at 8 mm, primarily because of the reduced partial volume effect. Conclusion: Our preliminary results suggest that EBCT, operated in multislice scan mode, may be useful for transvenous coronary angiography performed within a single breath-hold.
引用
收藏
页码:383 / 389
页数:7
相关论文
共 50 条
  • [31] Accuracy of coronary artery dimensions with electron-beam CT angiography: Comparison of measurement methods
    Funabashi, N
    Rubin, GD
    Kobayashi, Y
    Shifrin, RY
    Wexler, L
    Perlroth, M
    [J]. RADIOLOGY, 1999, 213P : 269 - 269
  • [32] Aortic atherosclerosis detected with electron-beam CT as a predictor of obstructive coronary artery disease
    Takasu, J
    Mao, S
    Budoff, MJ
    [J]. ACADEMIC RADIOLOGY, 2003, 10 (06) : 631 - 637
  • [33] Radiation dose from electron-beam CT
    Schoepf, T
    Recheis, WA
    Knapp, R
    Bangerl, I
    ZurNedden, D
    [J]. RADIOLOGY, 1996, 201 : 1071 - 1071
  • [34] Endomyocardial fibrosis: Electron-beam CT features
    Mousseaux, E
    Hernigou, A
    Azencot, M
    Sapoval, M
    Auguste, M
    Papo, T
    Chauvaud, S
    Gaux, JC
    [J]. RADIOLOGY, 1996, 198 (03) : 755 - 760
  • [35] RADIATION-DOSIMETRY FOR ELECTRON-BEAM CT
    MCCOLLOUGH, CH
    ZINK, FE
    MORIN, RL
    [J]. RADIOLOGY, 1994, 192 (03) : 637 - 643
  • [36] Horseshoe lung: demonstration by electron-beam CT
    Takahashi, M
    Murata, K
    Yamori, M
    Okuno, M
    Nakagawa, M
    Mori, M
    Furuichi, K
    Morita, R
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (837): : 964 - 966
  • [37] DEFLECTION OF THE ELECTRON-BEAM IN ELECTRON-BEAM WELDING
    NAZARENKO, OK
    [J]. AUTOMATIC WELDING USSR, 1982, 35 (01): : 28 - 33
  • [38] Coronary artery calcium quantification at multi-detector row helical CT versus electron-beam CT
    Stanford, W
    Thompson, BH
    Burns, TL
    Heery, SD
    Burr, MC
    [J]. RADIOLOGY, 2004, 230 (02) : 397 - 402
  • [39] Coronary artery stenoses: Assessment with contrast-enhanced electron-beam CT and axial reconstructions
    Reddy, GP
    Chernoff, DM
    Adams, JR
    Higgins, CB
    [J]. RADIOLOGY, 1998, 208 (01) : 167 - 172
  • [40] Coronary calcification at electron-beam CT: Effect of section thickness on calcium scoring in vitro and in vivo
    Vliegenthart, R
    Song, B
    Hofman, A
    Witteman, JCM
    Oudkerk, M
    [J]. RADIOLOGY, 2003, 229 (02) : 520 - 525