Reproducibility of Automatic Endothelial Cell Analysis Performed With Non-Contact Specular Microscopy

被引:0
|
作者
Gurlu, Vuslat Pelitli [1 ]
Bulbul, Ebru Demet [1 ]
Erda, Sait [1 ]
机构
[1] Trakya Univ, Tip Fak Goz Hast AD, Edirne, Turkey
关键词
Specular microscopy; corneal endothelium; cell density; coefficient of variation; hexagonality;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To investigate the reproducibility of automatic endothelial cell analysis performed with non-contact specular microscopes. Method: Fifteen eyes of 15 case were included in the study. From each eye 2 consecutive endothelial images of central cornea obtained with the Topcon SP-2000P by the first observer. Firstly, first image of each eye was assessed by correcting the cell borders defined by automatic analysis system (IMAGEnet) and using standart frame. "Intra-operator reproducibility" was investigated by comparison of results of these analysis with the analysis results of uncorrected cell borders defined by the automatic analysis system (I), with the use of smaller frame rather than the standard frame (II) and with the analysis results of second image of each eye captured by the first observer (III). In the second phase, "inter-operator reproducibility" was investigated by comparison of the results of the first observer with the results obtained by assessment of the first image of each eye by a second observer. Findings: Both the assesment made for the intra-operator reproducibility and inter-operator reproducibility revealed a medium-low degree of correlation for the coefficient of variation and hexagonality rates while a high correlation was observed for the values of cell density and average cell area. Conclusion: In conclusion, assesments made with the non-contact specular microscopy and automatic analysis system have a substantially high rate of reproducibility when standard frame and corrected cell borders are used.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 50 条
  • [41] Laser scanning microscopy - Fast, non-contact analysis of microstructures
    Reischer, Franz
    Zimmermann, Bernhard
    [J]. VDI Berichte, 2007, (1996): : 131 - 139
  • [42] Vibrational analysis of the cantilever in non-contact scanning force microscopy
    Kalousek, R
    Lopour, F
    Dub, P
    Sikola, T
    [J]. SURFACE AND INTERFACE ANALYSIS, 2000, 30 (01) : 292 - 296
  • [43] Comparison of central corneal thickness as measured by non-contact specular microscopy and ultrasound pachymetry before and post LASIK
    Zhao, Ming-Hui
    Zou, Jun
    Wang, Wen-Qing
    Li, Jun
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (09): : 818 - 823
  • [44] Non-contact scanning nonlinear dielectric microscopy
    Ohara, K
    Cho, Y
    [J]. NANOTECHNOLOGY, 2005, 16 (03) : S54 - S58
  • [45] A COMPARISON OF CONTACT AND NONCONTACT SPECULAR MICROSCOPY IN QUANTIFYING CORNEAL ENDOTHELIAL MORPHOLOGY
    STEVENSON, R
    KIRKNESS, CM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1598 - 1598
  • [46] Central corneal endothelial specular microscopy by contact and automated noncontact techniques
    McLaren, JW
    Nelson, LR
    Hodge, DO
    Bourne, WM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 625 - 625
  • [47] Non-contact feedback for scanning capillary microscopy
    Eng, L
    Wirth, E
    Suter, T
    Bohni, H
    [J]. ELECTROCHIMICA ACTA, 1998, 43 (19-20) : 3029 - 3033
  • [48] Frequency domain non-contact photoacoustic microscopy
    George, Deepu
    Lloyd, Harriet
    Silverman, Ronald H.
    Chitnis, Parag V.
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [49] Non-contact bimodal magnetic force microscopy
    Schwenk, J.
    Marioni, M.
    Romer, S.
    Joshi, N. R.
    Hug, H. J.
    [J]. APPLIED PHYSICS LETTERS, 2014, 104 (11)
  • [50] Contact and non-contact mode imaging by atomic force microscopy
    Morita, S
    Fujisawa, S
    Kishi, E
    Ohta, M
    Ueyama, H
    Sugawara, Y
    [J]. THIN SOLID FILMS, 1996, 273 (1-2) : 138 - 142